Skip to main content
Window · Wood Frame NFRC MAR · Product Line MAR-N-72 ENERGY STAR Most Efficient Eligible

Marvin — Ultimate Wood Double Hung Picture 2inch Sash · Picture Window

Across 105 Marvin certified families, Ultimate Wood Double Hung Picture 2inch Sash supplies 1,597 Picture Window configurations starting at 0.16 U-Factor and 0.10 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.41 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.10-0.41
Certified Options
1,597
Category Standing
#250 of 1,352

How does Marvin Ultimate Wood Double Hung Picture 2inch Sash compare thermally against Window peers?

Marvin Ultimate Wood Double Hung Picture 2inch Sash achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Ultimate Wood Double Hung Picture 2inch SashHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Ultimate Wood Double Hung Picture 2inch Sash (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Ultimate Wood Double Hung Picture 2inch Sash Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Marvin Ultimate Wood Double Hung Picture 2inch Sash at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.10-0.41 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 174 configurations meet ENERGY STAR Most Efficient criteria while 162 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2019-03-05 and v7.0 data certification on 2024-04-02. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,597 certified glazing combinations for Ultimate Wood Double Hung Picture 2inch Sash (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 162 packages (84 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 802 packages (146 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 897 packages (92 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,273 packages (116 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Ultimate Wood Double Hung Picture 2inch Sash appear below.

What thermal performance numbers separate Marvin Ultimate Wood Double Hung Picture 2inch Sash from peers?

Marvin Ultimate Wood Double Hung Picture 2inch Sash spans 1,597 certified configurations with U-Factors between 0.16 and 0.32 and SHGC values from 0.10 to 0.41. Ranked #250 of 1,352 Window families, it carries 174 Most Efficient options.

Can homeowners install Ultimate Wood Double Hung Picture 2inch Sash in cold Northern ENERGY STAR counties?

Yes, 162 packages satisfy Northern ENERGY STAR Version 7.0 rules in Ultimate Wood Double Hung Picture 2inch Sash. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does Ultimate Wood Double Hung Picture 2inch Sash conduct across a 15 sq ft opening?

At U 0.16, a standard 3x5 ft (15 sq ft) Ultimate Wood Double Hung Picture 2inch Sash opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.

Which situations make Ultimate Wood Double Hung Picture 2inch Sash the wrong window or door choice?

Do not specify Ultimate Wood Double Hung Picture 2inch Sash without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Ultimate Wood Double Hung Picture 2inch Sash options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in Ultimate Wood Double Hung Picture 2inch Sash?

Yes. 1,273 Southern-certified options inside Marvin Ultimate Wood Double Hung Picture 2inch Sash satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.41 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 1,597 Ultimate Wood Double Hung Picture 2inch Sash configurations ENERGY STAR Most Efficient?

Not every package qualifies: 174 of 1,597 Ultimate Wood Double Hung Picture 2inch Sash glazing builds earn Most Efficient recognition (10.9%), while other variants sit on the standard Version 7.0 tier.

Do 2026 Ultimate Wood Double Hung Picture 2inch Sash installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC MAR and product line MAR-N-72 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MAR and product line MAR-N-72, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Ultimate Wood Double Hung Picture 2inch Sash come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)