Milgard Manufacturing, Inc. — 3642/3662 Inswing Patio Door · Swinging Entry Door (Single)
With a minimum U-Factor of 0.23—+0.02 compared against the 0.21 Door median—Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door spans 1,049 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code MIL, the Fiberglass assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.32.
- Min U-Factor
- 0.23
- SHGC Range
- 0.12-0.32
- Certified Options
- 1,049
- Category Standing
- #162 of 268
How does Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door compare thermally against Door peers?
Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door standing at #162 of 268 certified Door product series, tied with 36 others at 0.23, more insulating than 26.1% of Door lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.
Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 128 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2025-01-30 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,049 certified glazing combinations for 3642/3662 Inswing Patio Door (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 128 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 128 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 1,024 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,024 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Andersen Corporation — Multi-Glide Patio Door - Clad Panels; Thermally Controlled Frame | Fiberglass | 0.23 | 0.10 | 1,161 |
| Marvin — Infinity Sliding Glass Door | Fiberglass | 0.23 | 0.15 | 301 |
| Weather Shield Mfg., Inc. — 8622 Premium / 8623 Contemporary Bi-Fold Door | Wood | 0.23 | 0.10 | 1,008 |
| JELD-WEN, inc. — Siteline Clad Swinging Door | Wood | 0.23 | 0.11 | 971 |
| Sierra Pacific Windows — Clad Outswing Door | Wood | 0.23 | 0.06 | 1,159 |
What other certified series does Milgard Manufacturing, Inc. produce?
Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8521T2.8531T2.8571T2 Casement Fixed
U-Factor 0.13–0.32 · 23,185 certified options.
8320T2.8330T2 Picture Window
U-Factor 0.14–0.32 · 22,562 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door appear below.
What U-Factor and SHGC range does Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door achieve?
Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door spans 1,049 certified configurations with U-Factors between 0.23 and 0.28 and SHGC values from 0.12 to 0.32. Ranked #162 of 268 Door families, it carries 0 Most Efficient options.
How does Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door satisfy Version 7.0 Northern criteria?
With a 0.23 minimum U-Factor, Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door cannot satisfy prescriptive <= 0.22 Northern targets, yet 128 high-SHGC packages meet EPA's solar-gain Equivalent route for cold northern homes.
What BTU/hr heat transfer results from 3642/3662 Inswing Patio Door's 0.23 minimum U-Factor?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 3642/3662 Inswing Patio Door at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What homeowner profiles are a poor match for Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 3642/3662 Inswing Patio Door options exceeding U 0.22. Verify whether your municipal code restricts Fiberglass frames in wildfire or historic zones.
Does 3642/3662 Inswing Patio Door meet Southern hot-climate SHGC caps (<= 0.23)?
Yes. 1,024 Southern-certified options inside Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.32 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in 3642/3662 Inswing Patio Door holds Most Efficient recognition?
ENERGY STAR Most Efficient designation is absent across all 1,049 3642/3662 Inswing Patio Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What federal compliance checks govern 2026 3642/3662 Inswing Patio Door window swaps?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 3642/3662 Inswing Patio Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
What permanent glass etch marks verify 3642/3662 Inswing Patio Door after sticker removal?
Confirm both the paper NFRC label and permanent corner glass etch match line MIL-A-242 and NFRC ID MIL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3642/3662 Inswing Patio Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)