Skip to main content
Door · Fiberglass Frame NFRC MAR · Product Line MAR-N-373

Marvin — Infinity Sliding Glass Door · Sliding Patio Door

Across 105 Marvin certified families, Infinity Sliding Glass Door supplies 301 Sliding Patio Door configurations starting at 0.23 U-Factor and 0.15 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.23 SHGC. Its thermal floor ranks #162 of 268 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.15-0.23
Certified Options
301
Category Standing
#162 of 268

How does Marvin Infinity Sliding Glass Door compare thermally against Door peers?

Marvin Infinity Sliding Glass Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Infinity Sliding Glass DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Infinity Sliding Glass Door (U 0.23).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.23430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Infinity Sliding Glass Door Cohort StandingMin U-Factor 0.23 stands at rank #162 of 268, outperforming 26.1% of peers.Min U-Factor 0.23Rank #162 of 268 (26.1% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Marvin Infinity Sliding Glass Door standing at #162 of 268 certified Door product series, tied with 36 others at 0.23, more insulating than 26.1% of Door lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.15 to 0.23) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 168 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2024-04-24 and FENSTAR license 2019-03-05 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 301 certified glazing combinations for Infinity Sliding Glass Door (NFRC MAR) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 168 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 168 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 301 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 301 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Marvin produce?

Compare other active Marvin certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Marvin Infinity Sliding Glass Door appear below.

What U-Factor and SHGC range does Marvin Infinity Sliding Glass Door achieve?

Marvin Infinity Sliding Glass Door spans 301 certified configurations with U-Factors between 0.23 and 0.28 and SHGC values from 0.15 to 0.23. Ranked #162 of 268 Door families, it carries 0 Most Efficient options.

Which glazing options in Marvin Infinity Sliding Glass Door meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above Infinity Sliding Glass Door's 0.23 minimum. However, 168 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

What BTU/hr heat transfer results from Infinity Sliding Glass Door's 0.23 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Marvin Infinity Sliding Glass Door for a residential project?

Do not specify Infinity Sliding Glass Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Infinity Sliding Glass Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does Infinity Sliding Glass Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, Infinity Sliding Glass Door holds 301 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.15 SHGC in cooling climates.

Does Infinity Sliding Glass Door carry EPA Most Efficient certification across its lineup?

Infinity Sliding Glass Door holds zero Most Efficient entries across its 301 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

How do the 25C sunset and pre-1978 Lead RRP rules affect Infinity Sliding Glass Door?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Marvin upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC MAR and product line MAR-N-373 on delivery?

Verify NFRC ID MAR and series MAR-N-373 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Marvin Infinity Sliding Glass Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros