Milgard Manufacturing, Inc. — 3645/3665 Outswing Patio Door · Swinging Entry Door (Single)
Across 58 Milgard Manufacturing, Inc. certified families, 3645/3665 Outswing Patio Door supplies 1,500 Swinging Entry Door, Single configurations starting at 0.23 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.33 SHGC. Its thermal floor ranks #162 of 268 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.23
- SHGC Range
- 0.12-0.33
- Certified Options
- 1,500
- Category Standing
- #162 of 268
How does Milgard Manufacturing, Inc. 3645/3665 Outswing Patio Door compare thermally against Door peers?
Milgard Manufacturing, Inc. 3645/3665 Outswing Patio Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Milgard Manufacturing, Inc. 3645/3665 Outswing Patio Door standing at #162 of 268 certified Door product series, tied with 36 others at 0.23, more insulating than 26.1% of Door lines. Comparing Fiberglass profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 176 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2025-01-30 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,500 certified glazing combinations for 3645/3665 Outswing Patio Door (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 176 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 176 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 1,467 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 1,467 packages (0 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Andersen Corporation — Multi-Glide Patio Door - Clad Panels; Thermally Controlled Frame | Fiberglass | 0.23 | 0.10 | 1,161 |
| Marvin — Infinity Sliding Glass Door | Fiberglass | 0.23 | 0.15 | 301 |
| MI Windows and Doors, LLC — 910 Polyvinyl Chloride (PVC) Sliding Glass Door | Vinyl | 0.23 | 0.13 | 1,324 |
| Sierra Pacific Windows — Clad Outswing Door | Wood | 0.23 | 0.06 | 1,159 |
| Weather Shield Mfg., Inc. — 8622 Premium / 8623 Contemporary Bi-Fold Door | Wood | 0.23 | 0.10 | 1,008 |
What other certified series does Milgard Manufacturing, Inc. produce?
Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8521T2.8531T2.8571T2 Casement Fixed
U-Factor 0.13–0.32 · 23,185 certified options.
8320T2.8330T2 Picture Window
U-Factor 0.14–0.32 · 22,562 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 3645/3665 Outswing Patio Door appear below.
How well does 3645/3665 Outswing Patio Door by Milgard Manufacturing, Inc. insulate relative to Door benchmarks?
Testing puts Milgard Manufacturing, Inc. 3645/3665 Outswing Patio Door at rank #162 of 268 Door entries with U 0.23 to 0.28 across 1,500 configurations. Solar heat gain ranges between 0.12 and 0.33 across Northern, North-Central, South-Central, Southern.
How does Milgard Manufacturing, Inc. 3645/3665 Outswing Patio Door satisfy Version 7.0 Northern criteria?
Prescriptive Northern approval ends at U <= 0.22, above 3645/3665 Outswing Patio Door's 0.23 minimum. However, 176 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.
How much winter heat loss does 3645/3665 Outswing Patio Door conduct across a 15 sq ft opening?
Using NFRC MIL U-Factor 0.23, a 15 sq ft Entry Door Single-Lite (EDSL) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).
Which situations make 3645/3665 Outswing Patio Door the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 3645/3665 Outswing Patio Door options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Does 3645/3665 Outswing Patio Door meet Southern hot-climate SHGC caps (<= 0.23)?
Yes. 1,467 Southern-certified options inside Milgard Manufacturing, Inc. 3645/3665 Outswing Patio Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.33 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in 3645/3665 Outswing Patio Door holds Most Efficient recognition?
ENERGY STAR Most Efficient designation is absent across all 1,500 3645/3665 Outswing Patio Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
How do the 25C sunset and pre-1978 Lead RRP rules affect 3645/3665 Outswing Patio Door?
Any 3645/3665 Outswing Patio Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
Where are NFRC and IGCC identification marks located on 3645/3665 Outswing Patio Door?
Inspectors match the temporary NFRC sticker (U 0.23-0.28, SHGC 0.12-0.33) against permit drawings for line MIL-A-246. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 3645/3665 Outswing Patio Door come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)