Skip to main content
Door · Vinyl Frame NFRC MEI · Product Line MEI-A-55

MI Windows and Doors, LLC — 910 Polyvinyl Chloride (PVC) Sliding Glass Door · Sliding Patio Door

Across 48 MI Windows and Doors, LLC certified families, 910 Polyvinyl Chloride (PVC) Sliding Glass Door supplies 1,324 Sliding Patio Door configurations starting at 0.23 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.34 SHGC. Its thermal floor ranks #162 of 268 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.13-0.34
Certified Options
1,324
Category Standing
#162 of 268

How does MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door compare thermally against Door peers?

MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 910 Polyvinyl Chloride (PVC) Sliding Glass DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 910 Polyvinyl Chloride (PVC) Sliding Glass Door (U 0.23).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.23430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

910 Polyvinyl Chloride (PVC) Sliding Glass Door Cohort StandingMin U-Factor 0.23 stands at rank #162 of 268, outperforming 26.1% of peers.Min U-Factor 0.23Rank #162 of 268 (26.1% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 910 Polyvinyl Chloride (PVC) Sliding Glass Door spans 1,324 NFRC test records (MEI), ranking #162 of 268 Door families (tied with 36 others at 0.23, more insulating than 26.1% of Door lines). Its 0.23 thermal floor compares at +0.04 against the Vinyl median (0.19).

Climate coverage for MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 735 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-11 licensing and 2024-02-29 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,324 certified glazing combinations for 910 Polyvinyl Chloride (PVC) Sliding Glass Door (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 735 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 735 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,111 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,111 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door appear below.

What thermal performance numbers separate MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door from peers?

EPA ENERGY STAR v7.0 records 1,324 configurations for MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Does MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door qualify for the ENERGY STAR Northern Zone?

While MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door misses the <= 0.22 prescriptive mark (floor U 0.23), 735 packages still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

What BTU/hr heat transfer results from 910 Polyvinyl Chloride (PVC) Sliding Glass Door's 0.23 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 910 Polyvinyl Chloride (PVC) Sliding Glass Door at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make 910 Polyvinyl Chloride (PVC) Sliding Glass Door the wrong window or door choice?

Do not specify 910 Polyvinyl Chloride (PVC) Sliding Glass Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 910 Polyvinyl Chloride (PVC) Sliding Glass Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many 910 Polyvinyl Chloride (PVC) Sliding Glass Door glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 1,111 Southern-approved options within 910 Polyvinyl Chloride (PVC) Sliding Glass Door spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in 910 Polyvinyl Chloride (PVC) Sliding Glass Door holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 1,324 910 Polyvinyl Chloride (PVC) Sliding Glass Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Do 2026 910 Polyvinyl Chloride (PVC) Sliding Glass Door installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 MI Windows and Doors, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify 910 Polyvinyl Chloride (PVC) Sliding Glass Door glass specs on job sites?

Verify NFRC ID MEI and series MEI-A-55 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 910 Polyvinyl Chloride (PVC) Sliding Glass Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros