Milgard Manufacturing, Inc. — V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door · Sliding Patio Door

Across 58 Milgard Manufacturing, Inc. certified families, V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door supplies 1,698 Sliding Patio Door configurations starting at 0.23 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.34 SHGC. Its thermal floor ranks #162 of 268 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.13-0.34
Certified Options
1,698
Category Standing
#162 of 268

How does Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door compare thermally against Door peers?

Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door achieves a 0.23 thermal floor across Door lines, placing #162 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door (U 0.23).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.23430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door Cohort StandingMin U-Factor 0.23 stands at rank #162 of 268, outperforming 26.1% of peers.Min U-Factor 0.23Rank #162 of 268 (26.1% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door standing at #162 of 268 certified Door product series, tied with 36 others at 0.23, more insulating than 26.1% of Door lines. Comparing Vinyl profiles alone (median 0.19) shows +0.04 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 1,144 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2019-01-08 and v7.0 data certification on 2024-07-30. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,698 certified glazing combinations for V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 1,144 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 1,144 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,150 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,150 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door appear below.

How well does V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door by Milgard Manufacturing, Inc. insulate relative to Door benchmarks?

EPA ENERGY STAR v7.0 records 1,698 configurations for Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.23 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Which glazing options in Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door's 0.23 minimum. However, 1,144 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

What BTU/hr heat transfer results from V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door's 0.23 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door options exceeding U 0.22. Additionally, do not order Sliding Glass Door (DDSG) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door in Southern or South-Central zones?

Yes. 1,150 Southern-certified options inside Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.34 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 1,698 V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door configurations ENERGY STAR Most Efficient?

Zero glazing builds inside V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door's 1,698 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What 2026 federal tax credit and Lead RRP rules apply to V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC MIL and product line MIL-A-317 on delivery?

Inspectors match the temporary NFRC sticker (U 0.23-0.28, SHGC 0.13-0.34) against permit drawings for line MIL-A-317. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. V350 (390) Polyvinyl Chloride (PVC) Sliding Glass Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)