Skip to main content
Window · Vinyl Frame NFRC MIL · Product Line MIL-A-261

Milgard Manufacturing, Inc. — 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement · Casement Windows

With a minimum U-Factor of 0.23—+0.03 compared against the 0.20 Window median—Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement spans 7,769 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MIL, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.09 and 0.46.

Min U-Factor
0.23
SHGC Range
0.09-0.46
Certified Options
7,769
Category Standing
#936 of 1,352

How does Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement compare thermally against Window peers?

Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 6510/6511/6530/6570/6510T/6511T/6530T/6570T CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.32.

Climate coverage for Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 306 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2026-04-02 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,769 certified glazing combinations for 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 306 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 2,386 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 4,991 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 7,020 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement appear below.

How efficient is Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement compared with peer Window models?

Testing puts Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement at rank #936 of 1,352 Window entries with U 0.23 to 0.32 across 7,769 configurations. Solar heat gain ranges between 0.09 and 0.46 across Northern, North-Central, South-Central, Southern.

Can homeowners install 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement in cold Northern ENERGY STAR counties?

Northern qualification on 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 306 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

How does a 3x5 ft 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement window perform under a 40 deg F temperature drop?

Using NFRC MIL U-Factor 0.23, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

Which situations make 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement glazing packages pass Southern solar-heat rules?

Exactly 7,020 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.46 glass.

Which package tier in 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement holds Most Efficient recognition?

All 7,769 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line MIL-A-261 and NFRC ID MIL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros