Milgard Manufacturing, Inc. — 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement · Casement Windows
With a minimum U-Factor of 0.23—+0.03 compared against the 0.20 Window median—Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement spans 7,769 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code MIL, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.09 and 0.46.
- Min U-Factor
- 0.23
- SHGC Range
- 0.09-0.46
- Certified Options
- 7,769
- Category Standing
- #936 of 1,352
How does Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement compare thermally against Window peers?
Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.32.
Climate coverage for Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 306 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.23 U-Factor yields 138.0 BTU/hr transfer (+6.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-08 licensing and 2026-04-02 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 7,769 certified glazing combinations for 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Equiv. Path | <= 0.22 | >= 0.17 | 306 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 2,386 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 4,991 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 7,020 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Atrium Companies, Inc. — 8300/1300/3201/40/3000 Double Hung | Vinyl | 0.23 | 0.15 | 1,886 |
| Windsor Windows and Doors — Next Dimension Casement | Vinyl | 0.23 | 0.14 | 1,638 |
| Windsor Windows and Doors — Next Dimension Awning | Vinyl | 0.23 | 0.14 | 1,583 |
| Amsco Windows — VS1 (Studio) EQ Picture Window | Vinyl | 0.23 | 0.13 | 1,395 |
| Associated Materials, Inc. — 1902 Horizontal Slider | Vinyl | 0.23 | 0.09 | 1,287 |
What other certified series does Milgard Manufacturing, Inc. produce?
Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8521T2.8531T2.8571T2 Casement Fixed
U-Factor 0.13–0.32 · 23,185 certified options.
8320T2.8330T2 Picture Window
U-Factor 0.14–0.32 · 22,562 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement appear below.
How efficient is Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement compared with peer Window models?
Testing puts Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement at rank #936 of 1,352 Window entries with U 0.23 to 0.32 across 7,769 configurations. Solar heat gain ranges between 0.09 and 0.46 across Northern, North-Central, South-Central, Southern.
Can homeowners install 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement in cold Northern ENERGY STAR counties?
Northern qualification on 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 306 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.
How does a 3x5 ft 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement window perform under a 40 deg F temperature drop?
Using NFRC MIL U-Factor 0.23, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).
Which situations make 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
How many 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement glazing packages pass Southern solar-heat rules?
Exactly 7,020 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.46 glass.
Which package tier in 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement holds Most Efficient recognition?
All 7,769 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
What 2026 federal tax credit and Lead RRP rules apply to 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
What permanent glass etch marks verify 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement after sticker removal?
Confirm both the paper NFRC label and permanent corner glass etch match line MIL-A-261 and NFRC ID MIL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. 6510/6511/6530/6570/6510T/6511T/6530T/6570T Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)