Skip to main content
Window · Vinyl Frame NFRC ADW · Product Line ADW-M-409

Atrium Companies, Inc. — 8300/1300/3201/40/3000 Double Hung · Double Hung

With a minimum U-Factor of 0.23—+0.03 compared against the 0.20 Window median—Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung spans 1,886 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code ADW, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.15 and 0.50.

Min U-Factor
0.23
SHGC Range
0.15-0.50
Certified Options
1,886
Category Standing
#936 of 1,352

How does Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung compare thermally against Window peers?

Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8300/1300/3201/40/3000 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 8300/1300/3201/40/3000 Double Hung (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8300/1300/3201/40/3000 Double Hung Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 8300/1300/3201/40/3000 Double Hung reaches 0.23 on its lowest-conductivity package — #716 of 1,009 in Vinyl, tied with 81 others at 0.23, more insulating than 21.0% of Vinyl lines (+0.04 vs Vinyl peers). Pairing NFRC ID ADW across multi-pane fills shifts U-Factor from 0.32 down toward 0.23.

Climate coverage for Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 165 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Registry history records EPA FENSTAR licensing on 2018-10-03 and v7.0 data certification on 2024-03-05. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.23 conducts 138.0 BTU/hr (+6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,886 certified glazing combinations for 8300/1300/3201/40/3000 Double Hung (NFRC ADW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 165 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 578 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,224 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,511 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Windsor Windows and Doors — Next Dimension Casement Vinyl 0.23 0.14 1,638
Windsor Windows and Doors — Next Dimension Awning Vinyl 0.23 0.14 1,583
Amsco Windows — VS1 (Studio) EQ Picture Window Vinyl 0.23 0.13 1,395
Associated Materials, Inc. — 1902 Horizontal Slider Vinyl 0.23 0.09 1,287
A Window, Inc. — SL3 Series Single Hung Vinyl 0.23 0.16 1,240

What other certified series does Atrium Companies, Inc. produce?

Compare other active Atrium Companies, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung appear below.

How efficient is Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung compared with peer Window models?

Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung spans 1,886 certified configurations with U-Factors between 0.23 and 0.32 and SHGC values from 0.15 to 0.50. Ranked #936 of 1,352 Window families, it carries 0 Most Efficient options.

How does Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung satisfy Version 7.0 Northern criteria?

Northern qualification on 8300/1300/3201/40/3000 Double Hung relies on EPA Equivalent solar pathways rather than prescriptive <= 0.22 limits, since its best glass sits at U 0.23. Exactly 165 packages pass Northern thresholds with air leakage <= 0.3 cfm/ft2.

What BTU/hr heat transfer results from 8300/1300/3201/40/3000 Double Hung's 0.23 minimum U-Factor?

At U 0.23, a standard 3x5 ft (15 sq ft) 8300/1300/3201/40/3000 Double Hung opening transfers 138.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +6.0 BTU/hr difference.

When should a buyer skip Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8300/1300/3201/40/3000 Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Is 8300/1300/3201/40/3000 Double Hung suitable for sunbelt cooling-dominated homes?

Exactly 1,511 8300/1300/3201/40/3000 Double Hung options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.15 rather than higher 0.50 glass.

Are all 1,886 8300/1300/3201/40/3000 Double Hung configurations ENERGY STAR Most Efficient?

All 1,886 8300/1300/3201/40/3000 Double Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 8300/1300/3201/40/3000 Double Hung installations qualify for IRS Section 25C tax credits?

Any 8300/1300/3201/40/3000 Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on 8300/1300/3201/40/3000 Double Hung?

Confirm both the paper NFRC label and permanent corner glass etch match line ADW-M-409 and NFRC ID ADW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Atrium Companies, Inc. 8300/1300/3201/40/3000 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros