Milgard Manufacturing, Inc. — HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window · Picture Window
Milgard Manufacturing, Inc. engineered the HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window Picture Window line for Northern, North-Central, South-Central, Southern, certifying 2,361 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.14 to 0.55 SHGC. Relative to other Vinyl models tracked under NFRC MIL, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.21
- SHGC Range
- 0.14-0.55
- Certified Options
- 2,361
- Category Standing
- #742 of 1,352
How does Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window compare thermally against Window peers?
Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 58 certified Milgard Manufacturing, Inc. series, this Picture Window offers a 0.11 U-Factor adjustment span between 0.32 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).
Climate coverage for Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 119 configurations meet ENERGY STAR Most Efficient criteria while 519 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2025-08-11.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 2,361 certified glazing combinations for HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 519 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 1,148 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 1,142 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,559 packages (119 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Associated Materials, Inc. — L204 Picture Window | Vinyl | 0.21 | 0.09 | 2,529 |
| MI Windows and Doors, LLC — 910 Polyvinyl Chloride (PVC) Transom | Vinyl | 0.21 | 0.14 | 2,530 |
| Amsco Windows — VS1 (Studio) Picture Window | Vinyl | 0.21 | 0.14 | 2,028 |
| Wincore Window Company, LLC — 400 500 Vinyl Fixed Window Transom | Vinyl | 0.21 | 0.13 | 2,892 |
| Wincore Window Company, LLC — 5400 5400S 7700 9900 Series Vinyl Fixed Window Sidelite | Vinyl | 0.21 | 0.06 | 1,724 |
What other certified series does Milgard Manufacturing, Inc. produce?
Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8521T2.8531T2.8571T2 Casement Fixed
U-Factor 0.13–0.32 · 23,185 certified options.
8320T2.8330T2 Picture Window
U-Factor 0.14–0.32 · 22,562 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window appear below.
Where does Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window stand thermally among ENERGY STAR Window lines?
Testing puts Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window at rank #742 of 1,352 Window entries with U 0.21 to 0.32 across 2,361 configurations. Solar heat gain ranges between 0.14 and 0.55 across Northern, North-Central, South-Central, Southern.
Does Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window qualify for the ENERGY STAR Northern Zone?
Yes, 519 packages satisfy Northern ENERGY STAR Version 7.0 rules in HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window. Pairing multi-pane insulation down to 0.21 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How do you calculate winter heat conduction for Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What homeowner profiles are a poor match for Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
How many HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window glazing packages pass Southern solar-heat rules?
Exactly 1,559 HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.14 rather than higher 0.55 glass.
How many Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window variants earn ENERGY STAR Most Efficient?
Only 119 options out of 2,361 (5.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window, usually requiring triple-pane or upgraded Low-E coatings.
Do 2026 HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window installations qualify for IRS Section 25C tax credits?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Milgard Manufacturing, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window glass specs on job sites?
Inspectors match the temporary NFRC sticker (U 0.21-0.32, SHGC 0.14-0.55) against permit drawings for line MIL-A-307. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)