Skip to main content
Window · Vinyl Frame NFRC WCW · Product Line WCW-M-45 ENERGY STAR Most Efficient Eligible

Wincore Window Company, LLC — 400 500 Vinyl Fixed Window Transom · Picture Window

EPA ENERGY STAR Version 7.0 certifies 2,892 variants inside Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom, combining Vinyl frame construction with U-Factors spanning 0.21 to 0.32 and SHGC 0.13 to 0.52. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #742 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.21
SHGC Range
0.13-0.52
Certified Options
2,892
Category Standing
#742 of 1,352

How does Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom compare thermally against Window peers?

Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 500 Vinyl Fixed Window TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 400 500 Vinyl Fixed Window Transom (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 500 Vinyl Fixed Window Transom Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom standing at #742 of 1,352 certified Window product series, tied with 88 others at 0.21, more insulating than 38.6% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.02 before selecting Low-E tiers.

Mapping NFRC SHGC values (0.13 to 0.52) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 218 configurations meet ENERGY STAR Most Efficient criteria while 455 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2024-12-02. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.21 conducts 126.0 BTU/hr (-6.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,892 certified glazing combinations for 400 500 Vinyl Fixed Window Transom (NFRC WCW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 455 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 810 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2,013 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 2,574 packages (218 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Wincore Window Company, LLC produce?

Compare other active Wincore Window Company, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom appear below.

How efficient is Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom compared with peer Window models?

Built with Vinyl framing in Fixed Window (FIXD) style, Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom offers 2,892 Version 7.0 configurations from U 0.21 up to 0.32, posting +0.01 against the Window median of 0.20 with 218 Most Efficient picks.

Which glazing options in Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom meet Northern climate limits?

Cold-climate buyers get 455 compliant Northern packages inside 400 500 Vinyl Fixed Window Transom, reaching down to U 0.21. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

What BTU/hr heat transfer results from 400 500 Vinyl Fixed Window Transom's 0.21 minimum U-Factor?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 400 500 Vinyl Fixed Window Transom at U 0.21 conducts 126.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying 400 500 Vinyl Fixed Window Transom?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 500 Vinyl Fixed Window Transom options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Does 400 500 Vinyl Fixed Window Transom meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 2,574 Southern-approved options within 400 500 Vinyl Fixed Window Transom spanning SHGC down to 0.13. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does 400 500 Vinyl Fixed Window Transom carry EPA Most Efficient certification across its lineup?

Only 218 options out of 2,892 (7.5%) meet tighter Most Efficient U-Factor and SHGC thresholds in Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 400 500 Vinyl Fixed Window Transom window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Wincore Window Company, LLC upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify 400 500 Vinyl Fixed Window Transom glass specs on job sites?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WCW and product line WCW-M-45, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Wincore Window Company, LLC 400 500 Vinyl Fixed Window Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros