MI Windows and Doors, LLC — 4300 Polyvinyl Chloride (PVC) Single Hung Window · Single Hung
EPA ENERGY STAR Version 7.0 certifies 3,723 variants inside MI Windows and Doors, LLC 4300 Polyvinyl Chloride (PVC) Single Hung Window, combining Vinyl frame construction with U-Factors spanning 0.21 to 0.32 and SHGC 0.09 to 0.52. Qualifying for Northern, North-Central, South-Central, Southern, this Single Hung family places #742 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.21
- SHGC Range
- 0.09-0.52
- Certified Options
- 3,723
- Category Standing
- #742 of 1,352
How does MI Windows and Doors, LLC 4300 Polyvinyl Chloride (PVC) Single Hung Window compare thermally against Window peers?
MI Windows and Doors, LLC 4300 Polyvinyl Chloride (PVC) Single Hung Window achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 48 certified MI Windows and Doors, LLC series, this Single Hung offers a 0.11 U-Factor adjustment span between 0.32 entry options and 0.21 top-performing glazing. Category standing is #742/1,352 (tied with 88 others at 0.21, more insulating than 38.6% of Window lines).
Mapping NFRC SHGC values (0.09 to 0.52) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 142 configurations meet ENERGY STAR Most Efficient criteria while 282 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 126.0 BTU/hr (-4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-11 and cert timestamp 2024-02-29.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 3,723 certified glazing combinations for 4300 Polyvinyl Chloride (PVC) Single Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 282 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 1,300 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 2,082 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 3,266 packages (142 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| JELD-WEN, inc. — Builders Vinyl (V-2500) Fixed w/ Track Filler | Vinyl | 0.21 | 0.14 | 4,542 |
| Wincore Window Company, LLC — 400 500 Vinyl Fixed Window Transom | Vinyl | 0.21 | 0.13 | 2,892 |
| Associated Materials, Inc. — L204 Picture Window | Vinyl | 0.21 | 0.09 | 2,529 |
| Milgard Manufacturing, Inc. — 8225 Double Hung | Vinyl | 0.21 | 0.10 | 5,062 |
| Milgard Manufacturing, Inc. — HM 155-V450-55 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window | Vinyl | 0.21 | 0.14 | 2,361 |
What other certified series does MI Windows and Doors, LLC produce?
Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
9660/9770 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.12–0.32 · 8,307 certified options.
9660-9770 Polyvinyl Chloride (PVC) Fixed (Sash Set) Window
U-Factor 0.13–0.32 · 6,920 certified options.
1615T Polyvinyl Chloride (PVC) Transom
U-Factor 0.14–0.31 · 3,234 certified options.
3075/3065 Direct Set Picture Window
U-Factor 0.14–0.32 · 35,308 certified options.
SR CASE PW Vinyl Fixed Window
U-Factor 0.14–0.31 · 5,254 certified options.
1650 Polyvinyl Chloride (PVC) Fixed (Direct Set) Window
U-Factor 0.15–0.32 · 11,774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 4300 Polyvinyl Chloride (PVC) Single Hung Window appear below.
How well does 4300 Polyvinyl Chloride (PVC) Single Hung Window by MI Windows and Doors, LLC insulate relative to Window benchmarks?
EPA ENERGY STAR v7.0 records 3,723 configurations for MI Windows and Doors, LLC 4300 Polyvinyl Chloride (PVC) Single Hung Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.21 versus a 0.20 Window median. Only 142 options earn Most Efficient status.
Is 4300 Polyvinyl Chloride (PVC) Single Hung Window approved for Northern Zone heating climates?
Yes. 282 packages in MI Windows and Doors, LLC 4300 Polyvinyl Chloride (PVC) Single Hung Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
How do you calculate winter heat conduction for MI Windows and Doors, LLC 4300 Polyvinyl Chloride (PVC) Single Hung Window?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What are the practical limitations of specifying 4300 Polyvinyl Chloride (PVC) Single Hung Window?
Skip 4300 Polyvinyl Chloride (PVC) Single Hung Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 4300 Polyvinyl Chloride (PVC) Single Hung Window options exceeding U 0.22.
Does 4300 Polyvinyl Chloride (PVC) Single Hung Window meet Southern hot-climate SHGC caps (<= 0.23)?
Exactly 3,266 4300 Polyvinyl Chloride (PVC) Single Hung Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.09 rather than higher 0.52 glass.
What glazing share inside 4300 Polyvinyl Chloride (PVC) Single Hung Window qualifies as Most Efficient?
No. Exactly 142 of 3,723 configurations (3.8%) earn ENERGY STAR Most Efficient status in 4300 Polyvinyl Chloride (PVC) Single Hung Window; the remaining standard v7.0 options pass base zone limits only.
What federal compliance checks govern 2026 4300 Polyvinyl Chloride (PVC) Single Hung Window window swaps?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do building inspectors verify 4300 Polyvinyl Chloride (PVC) Single Hung Window glass specs on job sites?
Verify NFRC ID MEI and series MEI-A-108 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 4300 Polyvinyl Chloride (PVC) Single Hung Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)