Skip to main content
Window · Vinyl Frame NFRC MIL · Product Line MIL-A-305

Milgard Manufacturing, Inc. — V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window · Single Hung

EPA ENERGY STAR Version 7.0 certifies 7,943 variants inside Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window, combining Vinyl frame construction with U-Factors spanning 0.23 to 0.32 and SHGC 0.07 to 0.50. Qualifying for Northern, North-Central, South-Central, Southern, this Single Hung family places #936 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.23
SHGC Range
0.07-0.50
Certified Options
7,943
Category Standing
#936 of 1,352

How does Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window compare thermally against Window peers?

Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 58 certified Milgard Manufacturing, Inc. series, this Single Hung offers a 0.09 U-Factor adjustment span between 0.32 entry options and 0.23 top-performing glazing. Category standing is #936/1,352 (tied with 97 others at 0.23, more insulating than 23.6% of Window lines).

Climate coverage for Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 184 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2026-03-19 and FENSTAR license 2019-01-08 inside EPA Version 7.0 tables. Heat transfer computes to 138.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,943 certified glazing combinations for V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 184 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 1,043 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 3,208 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 7,409 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window appear below.

What U-Factor and SHGC range does Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window achieve?

Across 7,943 tested NFRC glazing configurations, Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window with Vinyl framing and Single-Hung (VSSH) style reaches a 0.23 minimum U-Factor and 0.07-0.50 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.

How does Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window satisfy Version 7.0 Northern criteria?

Because V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window starts at 0.23 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 184 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

How do you calculate winter heat conduction for Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window at U 0.23 conducts 138.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What are the practical limitations of specifying V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window?

Skip V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window options exceeding U 0.22.

Is V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window suitable for sunbelt cooling-dominated homes?

Yes, V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window holds 7,409 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.07 SHGC in cooling climates.

How many Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window variants earn ENERGY STAR Most Efficient?

Zero glazing builds inside V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window's 7,943 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

What federal compliance checks govern 2026 V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MIL and product line MIL-A-305, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. V450 | HM150 Polyvinyl Chloride (PVC) Single Hung Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)