Window · Vinyl Frame NFRC MIL · Product Line MIL-A-306

Milgard Manufacturing, Inc. — V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window · Single Slider

Milgard Manufacturing, Inc. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window is a Single Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.23 across 7,941 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #936 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.07 to 0.50.

Min U-Factor
0.23
SHGC Range
0.07-0.50
Certified Options
7,941
Category Standing
#936 of 1,352

How does Milgard Manufacturing, Inc. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window compare thermally against Window peers?

Milgard Manufacturing, Inc. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window is 0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.23-0.32.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.23 floor sits above the 0.22 prescriptive Northern ceiling, 180 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 138.0 BTU/hr (+4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2019-01-08 and cert timestamp 2026-03-19.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,941 certified glazing combinations for V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window (NFRC MIL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 180 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 1,008 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 3,221 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 7,423 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Milgard Manufacturing, Inc. produce?

Compare other active Milgard Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Milgard Manufacturing, Inc. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window appear below.

What thermal performance numbers separate Milgard Manufacturing, Inc. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window from peers?

Across 7,941 tested NFRC glazing configurations, Milgard Manufacturing, Inc. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window with Vinyl framing and Horizontal Slider (HSOX) style reaches a 0.23 minimum U-Factor and 0.07-0.50 SHGC band. It places #936 among 1,352 Window series—more insulating than 23.6%.

Can homeowners install V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window in cold Northern ENERGY STAR counties?

Because V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window starts at 0.23 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 180 Northern packages qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

What conductive BTU/hr difference separates V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window from the 0.22 Northern rule?

Using NFRC MIL U-Factor 0.23, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 138.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+6.0 BTU/hr margin).

Who should NOT choose Milgard Manufacturing, Inc. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window for a residential project?

Skip V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window options exceeding U 0.22.

Is V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window suitable for sunbelt cooling-dominated homes?

Exactly 7,423 V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.07 rather than higher 0.50 glass.

Are all 7,941 V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window configurations ENERGY STAR Most Efficient?

All 7,941 V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What 2026 federal tax credit and Lead RRP rules apply to V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window after sticker removal?

Match the NFRC thermal sticker for code MIL and line MIL-A-306 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Milgard Manufacturing, Inc. V450 | HM160 Polyvinyl Chloride (PVC) Horizontal Sliding Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros