Skip to main content
Window · Vinyl Frame NFRC PEL · Product Line PEL-K-264

Pella Corporation — Pella Hurricane Shield Series FX-530 - Fixed · Picture Window

EPA ENERGY STAR Version 7.0 certifies 150 variants inside Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed, combining Vinyl frame construction with U-Factors spanning 0.25 to 0.32 and SHGC 0.15 to 0.24. Qualifying for North-Central, South-Central, Southern, this Picture Window family places #1,174 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.25
SHGC Range
0.15-0.24
Certified Options
150
Category Standing
#1,174 of 1,352

How does Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed compare thermally against Window peers?

Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pella Hurricane Shield Series FX-530 - FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.25-0.27 containing Pella Hurricane Shield Series FX-530 - Fixed (U 0.25).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27This model: U 0.25310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pella Hurricane Shield Series FX-530 - Fixed Cohort StandingMin U-Factor 0.25 stands at rank #1,174 of 1,352, outperforming 7.2% of peers.Min U-Factor 0.25Rank #1,174 of 1,352 (7.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Pella Hurricane Shield Series FX-530 - Fixed spans 150 NFRC test records (PEL), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.

Lifecycle documentation anchors PEL to 2025-08-11 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 150.0 BTU/hr conductive loss (+13.6% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 150 certified glazing combinations for Pella Hurricane Shield Series FX-530 - Fixed (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 28 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 67 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 144 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Custom Window Systems, Inc. — PW-8300 Fixed Vinyl 0.25 0.15 150
Burris Windows — TectView AC Single Hung Vinyl 0.25 0.12 135
Anlin Industries — Monte Verde Horizontal Sliding Vinyl 0.25 0.13 173
Anlin Industries — Monte Verde Single Hung Vinyl 0.25 0.13 179
Hometime Windows & Doors — 1600 Horizontal Slider Vinyl 0.25 0.13 119

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed appear below.

What U-Factor and SHGC range does Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed achieve?

Across 150 tested NFRC glazing configurations, Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed with Vinyl framing and Fixed Window (FIXD) style reaches a 0.25 minimum U-Factor and 0.15-0.24 SHGC band. It places #1,174 among 1,352 Window series—more insulating than 7.2%.

How does Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed satisfy Version 7.0 Northern criteria?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.25). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.15-0.24 manages cooling loads.

How much winter heat loss does Pella Hurricane Shield Series FX-530 - Fixed conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on Pella Hurricane Shield Series FX-530 - Fixed's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What are the practical limitations of specifying Pella Hurricane Shield Series FX-530 - Fixed?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Hurricane Shield Series FX-530 - Fixed options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Pella Hurricane Shield Series FX-530 - Fixed?

Warm-climate homeowners have 144 Southern-approved options within Pella Hurricane Shield Series FX-530 - Fixed spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does Pella Hurricane Shield Series FX-530 - Fixed carry EPA Most Efficient certification across its lineup?

All 150 Pella Hurricane Shield Series FX-530 - Fixed listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

How do the 25C sunset and pre-1978 Lead RRP rules affect Pella Hurricane Shield Series FX-530 - Fixed?

Any Pella Hurricane Shield Series FX-530 - Fixed purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Pella Hurricane Shield Series FX-530 - Fixed?

Verify NFRC ID PEL and series PEL-K-264 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros