Pella Corporation — Pella Hurricane Shield Series FX-530 - Fixed · Picture Window
EPA ENERGY STAR Version 7.0 certifies 150 variants inside Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed, combining Vinyl frame construction with U-Factors spanning 0.25 to 0.32 and SHGC 0.15 to 0.24. Qualifying for North-Central, South-Central, Southern, this Picture Window family places #1,174 of 1,352 among 1,352 Window families and posts 0.06 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.25
- SHGC Range
- 0.15-0.24
- Certified Options
- 150
- Category Standing
- #1,174 of 1,352
How does Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed compare thermally against Window peers?
Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed achieves a 0.25 thermal floor across Window lines, placing #1,174 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across Pella Hurricane Shield Series FX-530 - Fixed spans 150 NFRC test records (PEL), ranking #1,174 of 1,352 Window families (tied with 81 others at 0.25, more insulating than 7.2% of Window lines). Its 0.25 thermal floor compares at +0.06 against the Vinyl median (0.19).
Zone eligibility across EPA boundaries reaches 3 markets (North-Central, South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.15 lowers cooling load.
Lifecycle documentation anchors PEL to 2025-08-11 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 150.0 BTU/hr conductive loss (+13.6% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 150 certified glazing combinations for Pella Hurricane Shield Series FX-530 - Fixed (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 28 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 67 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 144 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.25 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Custom Window Systems, Inc. — PW-8300 Fixed | Vinyl | 0.25 | 0.15 | 150 |
| Burris Windows — TectView AC Single Hung | Vinyl | 0.25 | 0.12 | 135 |
| Anlin Industries — Monte Verde Horizontal Sliding | Vinyl | 0.25 | 0.13 | 173 |
| Anlin Industries — Monte Verde Single Hung | Vinyl | 0.25 | 0.13 | 179 |
| Hometime Windows & Doors — 1600 Horizontal Slider | Vinyl | 0.25 | 0.13 | 119 |
What other certified series does Pella Corporation produce?
Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Pella Entry Doors - Wood Edge Steel Door
U-Factor 0.13–0.28 · 76,045 certified options.
250 Series / Power Symphony Fixed
U-Factor 0.14–0.32 · 266 certified options.
250 Series / Power Symphony / CWS Comfort Shield / Burris TectView Fixed Casement
U-Factor 0.15–0.32 · 144 certified options.
Architect Wood Fixed Casement
U-Factor 0.15–0.32 · 2,468 certified options.
Pella Entry Doors - Fiberglass Skin Door
U-Factor 0.15–0.28 · 242,982 certified options.
Pella Entry Doors - Fiberglass Skin Sidelite
U-Factor 0.15–0.28 · 319,127 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed appear below.
What U-Factor and SHGC range does Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed achieve?
Across 150 tested NFRC glazing configurations, Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed with Vinyl framing and Fixed Window (FIXD) style reaches a 0.25 minimum U-Factor and 0.15-0.24 SHGC band. It places #1,174 among 1,352 Window series—more insulating than 7.2%.
How does Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed satisfy Version 7.0 Northern criteria?
This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.25). Focus on North-Central, South-Central, Southern glazing applications where SHGC 0.15-0.24 manages cooling loads.
How much winter heat loss does Pella Hurricane Shield Series FX-530 - Fixed conduct across a 15 sq ft opening?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 150.0 BTU/hr on Pella Hurricane Shield Series FX-530 - Fixed's lowest-U package (0.25), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
What are the practical limitations of specifying Pella Hurricane Shield Series FX-530 - Fixed?
Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Hurricane Shield Series FX-530 - Fixed options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.
What Southern ENERGY STAR v7.0 options exist in Pella Hurricane Shield Series FX-530 - Fixed?
Warm-climate homeowners have 144 Southern-approved options within Pella Hurricane Shield Series FX-530 - Fixed spanning SHGC down to 0.15. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Does Pella Hurricane Shield Series FX-530 - Fixed carry EPA Most Efficient certification across its lineup?
All 150 Pella Hurricane Shield Series FX-530 - Fixed listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.
How do the 25C sunset and pre-1978 Lead RRP rules affect Pella Hurricane Shield Series FX-530 - Fixed?
Any Pella Hurricane Shield Series FX-530 - Fixed purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
Where are NFRC and IGCC identification marks located on Pella Hurricane Shield Series FX-530 - Fixed?
Verify NFRC ID PEL and series PEL-K-264 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Hurricane Shield Series FX-530 - Fixed come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)