Window · Aluminum Frame NFRC QWP · Product Line QWP-M-115 ENERGY STAR Most Efficient Eligible

Quaker Window Products — C600/C300 Casement · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 4,263 variants inside Quaker Window Products C600/C300 Casement, combining Aluminum frame construction with U-Factors spanning 0.19 to 0.32 and SHGC 0.11 to 0.39. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #564 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.23 Btu/hr·ft²·°F median among Aluminum peers.

Min U-Factor
0.19
SHGC Range
0.11-0.39
Certified Options
4,263
Category Standing
#564 of 1,352

How does Quaker Window Products C600/C300 Casement compare thermally against Window peers?

Quaker Window Products C600/C300 Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. C600/C300 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing C600/C300 Casement (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

C600/C300 Casement Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 25 certified Quaker Window Products series, this Casement Windows offers a 0.13 U-Factor adjustment span between 0.32 entry options and 0.19 top-performing glazing. Category standing is #564/1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%).

Mapping NFRC SHGC values (0.11 to 0.39) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 584 configurations meet ENERGY STAR Most Efficient criteria while 292 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2024-07-08 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4,263 certified glazing combinations for C600/C300 Casement (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 292 packages (47 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,983 packages (167 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 2,764 packages (148 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 3,946 packages (565 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products C600/C300 Casement appear below.

Where does Quaker Window Products C600/C300 Casement stand thermally among ENERGY STAR Window lines?

Across 4,263 tested NFRC glazing configurations, Quaker Window Products C600/C300 Casement with Aluminum framing and Casement Single-Vent (CSSV) style reaches a 0.19 minimum U-Factor and 0.11-0.39 SHGC band. It places #564 among 1,352 Window series—top 49.6%.

Is C600/C300 Casement approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 292 C600/C300 Casement packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How does a 3x5 ft C600/C300 Casement window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), C600/C300 Casement at U 0.19 conducts 114.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make C600/C300 Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on C600/C300 Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many C600/C300 Casement glazing packages pass Southern solar-heat rules?

Exactly 3,946 C600/C300 Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.11 rather than higher 0.39 glass.

How many Quaker Window Products C600/C300 Casement variants earn ENERGY STAR Most Efficient?

Only 584 options out of 4,263 (13.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Quaker Window Products C600/C300 Casement, usually requiring triple-pane or upgraded Low-E coatings.

Do 2026 C600/C300 Casement installations qualify for IRS Section 25C tax credits?

Any C600/C300 Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on C600/C300 Casement?

Verify NFRC ID QWP and series QWP-M-115 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products C600/C300 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)