Skip to main content
Window · Aluminum Frame NFRC QWP · Product Line QWP-M-113 ENERGY STAR Most Efficient Eligible

Quaker Window Products — W600/W300 Awning · Awning (Projected)

Quaker Window Products engineered the W600/W300 Awning Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 7,025 glass-spacer combinations from 0.19 to 0.32 U-Factor and 0.11 to 0.43 SHGC. Relative to other Aluminum models tracked under NFRC QWP, its minimum U-Factor is 0.04 Btu/hr·ft²·°F more insulating than the 0.23 Btu/hr·ft²·°F median.

Min U-Factor
0.19
SHGC Range
0.11-0.43
Certified Options
7,025
Category Standing
#564 of 1,352

How does Quaker Window Products W600/W300 Awning compare thermally against Window peers?

Quaker Window Products W600/W300 Awning achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. W600/W300 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing W600/W300 Awning (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

W600/W300 Awning Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), W600/W300 Awning is 0.01 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Aluminum frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.19-0.32.

Regional qualification covers Northern, North-Central, South-Central, Southern. 2,300 configurations meet ENERGY STAR Most Efficient criteria while 1,138 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-07-08.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 7,025 certified glazing combinations for W600/W300 Awning (NFRC QWP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 1,138 packages (392 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 4,903 packages (1,120 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 5,310 packages (952 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 6,260 packages (2,132 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Quaker Window Products produce?

Compare other active Quaker Window Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Quaker Window Products W600/W300 Awning appear below.

How efficient is Quaker Window Products W600/W300 Awning compared with peer Window models?

Quaker Window Products W600/W300 Awning spans 7,025 certified configurations with U-Factors between 0.19 and 0.32 and SHGC values from 0.11 to 0.43. Ranked #564 of 1,352 Window families, it carries 2,300 Most Efficient options.

How does Quaker Window Products W600/W300 Awning satisfy Version 7.0 Northern criteria?

Yes, 1,138 packages satisfy Northern ENERGY STAR Version 7.0 rules in W600/W300 Awning. Pairing multi-pane insulation down to 0.19 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does W600/W300 Awning conduct across a 15 sq ft opening?

At U 0.19, a standard 3x5 ft (15 sq ft) W600/W300 Awning opening transfers 114.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -18.0 BTU/hr difference.

Which situations make W600/W300 Awning the wrong window or door choice?

Do not specify W600/W300 Awning without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on W600/W300 Awning options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is W600/W300 Awning suitable for sunbelt cooling-dominated homes?

Yes. 6,260 Southern-certified options inside Quaker Window Products W600/W300 Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.43 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside W600/W300 Awning qualifies as Most Efficient?

Only 2,300 options out of 7,025 (32.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Quaker Window Products W600/W300 Awning, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to W600/W300 Awning?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Quaker Window Products upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC QWP and product line QWP-M-113 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line QWP-M-113 and NFRC ID QWP before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Quaker Window Products W600/W300 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)