Skip to main content
Window · Wood Frame NFRC SIE · Product Line SIE-N-30 ENERGY STAR Most Efficient Eligible

Sierra Pacific Windows — Aluminum Clad Outswing Transom · Picture Window

Across 25 Sierra Pacific Windows certified families, Aluminum Clad Outswing Transom supplies 1,739 Picture Window configurations starting at 0.22 U-Factor and 0.09 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.43 SHGC. Its thermal floor ranks #831 of 1,352 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.09-0.43
Certified Options
1,739
Category Standing
#831 of 1,352

How does Sierra Pacific Windows Aluminum Clad Outswing Transom compare thermally against Window peers?

Sierra Pacific Windows Aluminum Clad Outswing Transom achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Aluminum Clad Outswing TransomHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Aluminum Clad Outswing Transom (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Aluminum Clad Outswing Transom Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 25 certified Sierra Pacific Windows series, this Picture Window offers a 0.10 U-Factor adjustment span between 0.32 entry options and 0.22 top-performing glazing. Category standing is #831/1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines).

Climate coverage for Sierra Pacific Windows Aluminum Clad Outswing Transom spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 18 configurations meet ENERGY STAR Most Efficient criteria while 41 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-21 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,739 certified glazing combinations for Aluminum Clad Outswing Transom (NFRC SIE) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 41 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 292 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 753 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,665 packages (18 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Sierra Pacific Windows produce?

Compare other active Sierra Pacific Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Sierra Pacific Windows Aluminum Clad Outswing Transom appear below.

Where does Sierra Pacific Windows Aluminum Clad Outswing Transom stand thermally among ENERGY STAR Window lines?

Testing puts Sierra Pacific Windows Aluminum Clad Outswing Transom at rank #831 of 1,352 Window entries with U 0.22 to 0.32 across 1,739 configurations. Solar heat gain ranges between 0.09 and 0.43 across Northern, North-Central, South-Central, Southern.

Which glazing options in Sierra Pacific Windows Aluminum Clad Outswing Transom meet Northern climate limits?

Sierra Pacific Windows Aluminum Clad Outswing Transom supplies 41 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Sierra Pacific Windows Aluminum Clad Outswing Transom?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Aluminum Clad Outswing Transom at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Sierra Pacific Windows Aluminum Clad Outswing Transom for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Aluminum Clad Outswing Transom options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Aluminum Clad Outswing Transom?

Across Northern, North-Central, South-Central, Southern, 1,665 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Sierra Pacific Windows Aluminum Clad Outswing Transom, while total line SHGC reaches 0.43 in colder packages.

Does Aluminum Clad Outswing Transom carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 18 of 1,739 Aluminum Clad Outswing Transom glazing builds earn Most Efficient recognition (1.0%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 Aluminum Clad Outswing Transom window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do you cross-check NFRC SIE and product line SIE-N-30 on delivery?

Match the NFRC thermal sticker for code SIE and line SIE-N-30 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Sierra Pacific Windows Aluminum Clad Outswing Transom come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros