Andersen Corporation — 400 Series Woodwright® Double-Hung Picture Full-Frame Window · Picture Window
Positioning #831/1,352 in certified Window, Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window pairs Wood frame construction with 1,345 glazing options rated between 0.15 and 0.48 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.22 to 0.32 U-Factor and the line includes 50 ENERGY STAR Most Efficient packages (3.7% of line).
- Min U-Factor
- 0.22
- SHGC Range
- 0.15-0.48
- Certified Options
- 1,345
- Category Standing
- #831 of 1,352
How does Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window compare thermally against Window peers?
Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 111 certified Andersen Corporation series, this Picture Window offers a 0.10 U-Factor adjustment span between 0.32 entry options and 0.22 top-performing glazing. Category standing is #831/1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines).
Climate coverage for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 50 configurations meet ENERGY STAR Most Efficient criteria while 163 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors AND to 2025-09-17 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,345 certified glazing combinations for 400 Series Woodwright® Double-Hung Picture Full-Frame Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 163 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 456 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 679 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,090 packages (50 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Sierra Pacific Windows — Monument Single Hung - Double Hung | Wood | 0.22 | 0.09 | 1,398 |
| JELD-WEN, inc. — Custom Wood Epic Double Hung Picture | Wood | 0.22 | 0.10 | 1,142 |
| Sierra Pacific Windows — Monument Horizontal Slider | Wood | 0.22 | 0.10 | 1,089 |
| Windsor Windows and Doors — Revive Clad Pocket Casement Picture | Wood | 0.22 | 0.16 | 1,064 |
| Marvin — Ultimate Wood Double Hung Transom | Wood | 0.22 | 0.11 | 1,687 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window appear below.
How well does 400 Series Woodwright® Double-Hung Picture Full-Frame Window by Andersen Corporation insulate relative to Window benchmarks?
EPA ENERGY STAR v7.0 records 1,345 configurations for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.20 Window median. Only 50 options earn Most Efficient status.
Can homeowners install 400 Series Woodwright® Double-Hung Picture Full-Frame Window in cold Northern ENERGY STAR counties?
Yes, 163 packages satisfy Northern ENERGY STAR Version 7.0 rules in 400 Series Woodwright® Double-Hung Picture Full-Frame Window. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How much winter heat loss does 400 Series Woodwright® Double-Hung Picture Full-Frame Window conduct across a 15 sq ft opening?
At U 0.22, a standard 3x5 ft (15 sq ft) 400 Series Woodwright® Double-Hung Picture Full-Frame Window opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.
When should a buyer skip Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Woodwright® Double-Hung Picture Full-Frame Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Can you install Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 1,090 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window, while total line SHGC reaches 0.48 in colder packages.
How many Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window variants earn ENERGY STAR Most Efficient?
EPA lists 50 Most Efficient options (3.7% share) inside Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window, out of 1,345 total Version 7.0 entries.
How do the 25C sunset and pre-1978 Lead RRP rules affect 400 Series Woodwright® Double-Hung Picture Full-Frame Window?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
Where are NFRC and IGCC identification marks located on 400 Series Woodwright® Double-Hung Picture Full-Frame Window?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code AND and product line AND-N-67, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)