Skip to main content
Window · Wood Frame NFRC AND · Product Line AND-N-67 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 400 Series Woodwright® Double-Hung Picture Full-Frame Window · Picture Window

Positioning #831/1,352 in certified Window, Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window pairs Wood frame construction with 1,345 glazing options rated between 0.15 and 0.48 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.22 to 0.32 U-Factor and the line includes 50 ENERGY STAR Most Efficient packages (3.7% of line).

Min U-Factor
0.22
SHGC Range
0.15-0.48
Certified Options
1,345
Category Standing
#831 of 1,352

How does Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window compare thermally against Window peers?

Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 400 Series Woodwright® Double-Hung Picture Full-Frame WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 400 Series Woodwright® Double-Hung Picture Full-Frame Window (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

400 Series Woodwright® Double-Hung Picture Full-Frame Window Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 111 certified Andersen Corporation series, this Picture Window offers a 0.10 U-Factor adjustment span between 0.32 entry options and 0.22 top-performing glazing. Category standing is #831/1,352 (tied with 104 others at 0.22, more insulating than 30.8% of Window lines).

Climate coverage for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 50 configurations meet ENERGY STAR Most Efficient criteria while 163 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors AND to 2025-09-17 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 132.0 BTU/hr conductive loss (equal to the 0.22 Northern floor).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,345 certified glazing combinations for 400 Series Woodwright® Double-Hung Picture Full-Frame Window (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 163 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 456 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 679 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,090 packages (50 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window appear below.

How well does 400 Series Woodwright® Double-Hung Picture Full-Frame Window by Andersen Corporation insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 1,345 configurations for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.20 Window median. Only 50 options earn Most Efficient status.

Can homeowners install 400 Series Woodwright® Double-Hung Picture Full-Frame Window in cold Northern ENERGY STAR counties?

Yes, 163 packages satisfy Northern ENERGY STAR Version 7.0 rules in 400 Series Woodwright® Double-Hung Picture Full-Frame Window. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does 400 Series Woodwright® Double-Hung Picture Full-Frame Window conduct across a 15 sq ft opening?

At U 0.22, a standard 3x5 ft (15 sq ft) 400 Series Woodwright® Double-Hung Picture Full-Frame Window opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

When should a buyer skip Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Series Woodwright® Double-Hung Picture Full-Frame Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 1,090 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window, while total line SHGC reaches 0.48 in colder packages.

How many Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window variants earn ENERGY STAR Most Efficient?

EPA lists 50 Most Efficient options (3.7% share) inside Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window, out of 1,345 total Version 7.0 entries.

How do the 25C sunset and pre-1978 Lead RRP rules affect 400 Series Woodwright® Double-Hung Picture Full-Frame Window?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on 400 Series Woodwright® Double-Hung Picture Full-Frame Window?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code AND and product line AND-N-67, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 400 Series Woodwright® Double-Hung Picture Full-Frame Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros