Skip to main content
Window · Wood Frame NFRC WIN · Product Line WIN-N-186 ENERGY STAR Most Efficient Eligible

Windsor Windows and Doors — Revive Clad Pocket Casement Picture · Picture Window

With a minimum U-Factor of 0.22—+0.02 compared against the 0.20 Window median—Windsor Windows and Doors Revive Clad Pocket Casement Picture spans 1,064 tested options across Northern, North-Central, South-Central, Southern up to 0.32 U-Factor. Carrying NFRC CPD code WIN, the Wood assembly includes 12 ENERGY STAR Most Efficient packages (1.1% of line) and offers SHGC packages between 0.16 and 0.51.

Min U-Factor
0.22
SHGC Range
0.16-0.51
Certified Options
1,064
Category Standing
#831 of 1,352

How does Windsor Windows and Doors Revive Clad Pocket Casement Picture compare thermally against Window peers?

Windsor Windows and Doors Revive Clad Pocket Casement Picture achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Revive Clad Pocket Casement PictureHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Revive Clad Pocket Casement Picture (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Revive Clad Pocket Casement Picture Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Windsor Windows and Doors Revive Clad Pocket Casement Picture standing at #831 of 1,352 certified Window product series, tied with 104 others at 0.22, more insulating than 30.8% of Window lines. Comparing Wood profiles alone (median 0.21) shows +0.01 before selecting Low-E tiers.

Regional qualification covers Northern, North-Central, South-Central, Southern. 12 configurations meet ENERGY STAR Most Efficient criteria while 102 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-17.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,064 certified glazing combinations for Revive Clad Pocket Casement Picture (NFRC WIN) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 102 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 174 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 548 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 977 packages (12 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Windsor Windows and Doors produce?

Compare other active Windsor Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Windsor Windows and Doors Revive Clad Pocket Casement Picture appear below.

How efficient is Windsor Windows and Doors Revive Clad Pocket Casement Picture compared with peer Window models?

Across 1,064 tested NFRC glazing configurations, Windsor Windows and Doors Revive Clad Pocket Casement Picture with Wood framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.16-0.51 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

How does Windsor Windows and Doors Revive Clad Pocket Casement Picture satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 102 compliant Northern packages inside Revive Clad Pocket Casement Picture, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.32 options.

How do you calculate winter heat conduction for Windsor Windows and Doors Revive Clad Pocket Casement Picture?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Revive Clad Pocket Casement Picture at U 0.22 conducts 132.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose Windsor Windows and Doors Revive Clad Pocket Casement Picture for a residential project?

Skip Revive Clad Pocket Casement Picture if local historic preservation boards prohibit Wood profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Revive Clad Pocket Casement Picture options exceeding U 0.22.

Is Revive Clad Pocket Casement Picture suitable for sunbelt cooling-dominated homes?

Yes, Revive Clad Pocket Casement Picture holds 977 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

Are all 1,064 Revive Clad Pocket Casement Picture configurations ENERGY STAR Most Efficient?

No. Exactly 12 of 1,064 configurations (1.1%) earn ENERGY STAR Most Efficient status in Revive Clad Pocket Casement Picture; the remaining standard v7.0 options pass base zone limits only.

What 2026 federal tax credit and Lead RRP rules apply to Revive Clad Pocket Casement Picture?

Any Revive Clad Pocket Casement Picture purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Windsor Windows and Doors Revive Clad Pocket Casement Picture units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIN and product line WIN-N-186, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Windsor Windows and Doors Revive Clad Pocket Casement Picture come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros