Door · Wood Frame NFRC SIE · Product Line SIE-N-108

Sierra Pacific Windows — Clad Inswing Door · Swinging Entry Door (Single)

Sierra Pacific Windows Clad Inswing Door is a Swinging Entry Door, Single assembly with a Wood frame that reaches a minimum U-Factor of 0.22 across 2,834 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #145 of 268 in Door, its thermal floor is 0.01 Btu/hr·ft²·°F less insulating than the 0.21 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.08 to 0.38.

Min U-Factor
0.22
SHGC Range
0.08-0.38
Certified Options
2,834
Category Standing
#145 of 268

How does Sierra Pacific Windows Clad Inswing Door compare thermally against Door peers?

Sierra Pacific Windows Clad Inswing Door achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Clad Inswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Clad Inswing Door (U 0.22).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.22430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Clad Inswing Door Cohort StandingMin U-Factor 0.22 stands at rank #145 of 268, outperforming 39.9% of peers.Min U-Factor 0.22Rank #145 of 268 (39.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 25 certified Sierra Pacific Windows series, this Swinging Entry Door, Single offers a 0.06 U-Factor adjustment span between 0.28 entry options and 0.22 top-performing glazing. Category standing is #145/268 (tied with 16 others at 0.22, more insulating than 39.9% of Door lines).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 1,240 combinations qualify in the Northern Zone alongside 2,592 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2018-01-10 and cert timestamp 2024-02-21.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,834 certified glazing combinations for Clad Inswing Door (NFRC SIE) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 1,240 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 1,240 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2,592 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2,592 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Sierra Pacific Windows produce?

Compare other active Sierra Pacific Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Sierra Pacific Windows Clad Inswing Door appear below.

What U-Factor and SHGC range does Sierra Pacific Windows Clad Inswing Door achieve?

Testing puts Sierra Pacific Windows Clad Inswing Door at rank #145 of 268 Door entries with U 0.22 to 0.28 across 2,834 configurations. Solar heat gain ranges between 0.08 and 0.38 across Northern, North-Central, South-Central, Southern.

How does Sierra Pacific Windows Clad Inswing Door satisfy Version 7.0 Northern criteria?

Yes, 1,240 packages satisfy Northern ENERGY STAR Version 7.0 rules in Clad Inswing Door. Pairing multi-pane insulation down to 0.22 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for Sierra Pacific Windows Clad Inswing Door?

Using NFRC SIE U-Factor 0.22, a 15 sq ft Entry Door Single-Lite (EDSL) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).

What homeowner profiles are a poor match for Sierra Pacific Windows Clad Inswing Door?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Clad Inswing Door options exceeding U 0.22. Verify whether your municipal code restricts Wood frames in wildfire or historic zones.

Can you install Sierra Pacific Windows Clad Inswing Door in Southern or South-Central zones?

Warm-climate homeowners have 2,592 Southern-approved options within Clad Inswing Door spanning SHGC down to 0.08. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside Clad Inswing Door qualifies as Most Efficient?

ENERGY STAR Most Efficient designation is absent across all 2,834 Clad Inswing Door options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What federal compliance checks govern 2026 Clad Inswing Door window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Clad Inswing Door retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC SIE and product line SIE-N-108 on delivery?

Match the NFRC thermal sticker for code SIE and line SIE-N-108 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Sierra Pacific Windows Clad Inswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)