Skip to main content
Door · Wood Frame NFRC AND · Product Line AND-N-212 ENERGY STAR Most Efficient Eligible

Andersen Corporation — A-Series Contemporary Gliding Patio Door (FWGCD) · Sliding Patio Door

Positioning #145/268 in certified Door, Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) pairs Wood frame construction with 977 glazing options rated between 0.11 and 0.39 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.22 to 0.28 U-Factor and the line includes 17 ENERGY STAR Most Efficient packages (1.7% of line).

Min U-Factor
0.22
SHGC Range
0.11-0.39
Certified Options
977
Category Standing
#145 of 268

How does Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) compare thermally against Door peers?

Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. A-Series Contemporary Gliding Patio Door (FWGCD)Histogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing A-Series Contemporary Gliding Patio Door (FWGCD) (U 0.22).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.22430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

A-Series Contemporary Gliding Patio Door (FWGCD) Cohort StandingMin U-Factor 0.22 stands at rank #145 of 268, outperforming 39.9% of peers.Min U-Factor 0.22Rank #145 of 268 (39.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) standing at #145 of 268 certified Door product series, tied with 16 others at 0.22, more insulating than 39.9% of Door lines. Comparing Wood profiles alone (median 0.21) shows +0.01 before selecting Low-E tiers.

Climate coverage for Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 17 configurations meet ENERGY STAR Most Efficient criteria while 436 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2019-01-08 and cert timestamp 2024-03-20.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 977 certified glazing combinations for A-Series Contemporary Gliding Patio Door (FWGCD) (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 436 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 436 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 845 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 845 packages (17 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) appear below.

Where does Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) stand thermally among ENERGY STAR Door lines?

Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) spans 977 certified configurations with U-Factors between 0.22 and 0.28 and SHGC values from 0.11 to 0.39. Ranked #145 of 268 Door families, it carries 17 Most Efficient options.

Does Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 436 compliant Northern packages inside A-Series Contemporary Gliding Patio Door (FWGCD), reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

What BTU/hr heat transfer results from A-Series Contemporary Gliding Patio Door (FWGCD)'s 0.22 minimum U-Factor?

At U 0.22, a standard 3x5 ft (15 sq ft) A-Series Contemporary Gliding Patio Door (FWGCD) opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

Which situations make A-Series Contemporary Gliding Patio Door (FWGCD) the wrong window or door choice?

Do not specify A-Series Contemporary Gliding Patio Door (FWGCD) without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Contemporary Gliding Patio Door (FWGCD) options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does A-Series Contemporary Gliding Patio Door (FWGCD) meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 845 Southern-approved options within A-Series Contemporary Gliding Patio Door (FWGCD) spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in A-Series Contemporary Gliding Patio Door (FWGCD) holds Most Efficient recognition?

Only 17 options out of 977 (1.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD), usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 A-Series Contemporary Gliding Patio Door (FWGCD) window swaps?

Any A-Series Contemporary Gliding Patio Door (FWGCD) purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) units match permits?

Match the NFRC thermal sticker for code AND and line AND-N-212 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros