Andersen Corporation — A-Series Contemporary Gliding Patio Door (FWGCD) · Sliding Patio Door
Positioning #145/268 in certified Door, Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) pairs Wood frame construction with 977 glazing options rated between 0.11 and 0.39 SHGC across Northern, North-Central, South-Central, Southern. Across 111 certified Andersen Corporation product families, its thermal resistance spans 0.22 to 0.28 U-Factor and the line includes 17 ENERGY STAR Most Efficient packages (1.7% of line).
- Min U-Factor
- 0.22
- SHGC Range
- 0.11-0.39
- Certified Options
- 977
- Category Standing
- #145 of 268
How does Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) compare thermally against Door peers?
Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) standing at #145 of 268 certified Door product series, tied with 16 others at 0.22, more insulating than 39.9% of Door lines. Comparing Wood profiles alone (median 0.21) shows +0.01 before selecting Low-E tiers.
Climate coverage for Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 17 configurations meet ENERGY STAR Most Efficient criteria while 436 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 132.0 BTU/hr (equal to the 0.22 Northern floor). Records show license timestamp 2019-01-08 and cert timestamp 2024-03-20.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 977 certified glazing combinations for A-Series Contemporary Gliding Patio Door (FWGCD) (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 436 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 436 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 845 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 845 packages (17 Most Eff.) |
Which competing Door series sit closest on U-Factor?
Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Sierra Pacific Windows — Aluminum Clad Inswing/Sidelite | Wood | 0.22 | 0.08 | 1,073 |
| Sierra Pacific Windows — Wood Outswing/Sidelite | Wood | 0.22 | 0.08 | 1,305 |
| Sierra Pacific Windows — Wood Inswing Door | Wood | 0.22 | 0.08 | 1,378 |
| Pella Corporation — Lifestyle Series with HGP - Inswing Door | Wood | 0.22 | 0.08 | 159 |
| JELD-WEN, inc. — Siteline (W-550) Clad Wood Sliding Door | Wood | 0.22 | 0.16 | 99 |
What other certified series does Andersen Corporation produce?
Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
100 Series/Series 2 Fixed/Specialty Windows
U-Factor 0.14–0.32 · 13,810 certified options.
Complementary Wood Specialty Windows - Direct-Set
U-Factor 0.14–0.32 · 7,588 certified options.
200 Series/400 Series Complementary Clad Specialty Windows
U-Factor 0.15–0.32 · 12,778 certified options.
400 Series Tilt-Wash Double-Hung Transom Full-Frame Window
U-Factor 0.15–0.32 · 2,446 certified options.
E-Series Specialty (Auxiliary) Window
U-Factor 0.15–0.32 · 16,775 certified options.
Renewal by Andersen® Entry Door – Panel Set Sidelight
U-Factor 0.15–0.28 · 24,853 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) appear below.
Where does Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) stand thermally among ENERGY STAR Door lines?
Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) spans 977 certified configurations with U-Factors between 0.22 and 0.28 and SHGC values from 0.11 to 0.39. Ranked #145 of 268 Door families, it carries 17 Most Efficient options.
Does Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) qualify for the ENERGY STAR Northern Zone?
Cold-climate buyers get 436 compliant Northern packages inside A-Series Contemporary Gliding Patio Door (FWGCD), reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.
What BTU/hr heat transfer results from A-Series Contemporary Gliding Patio Door (FWGCD)'s 0.22 minimum U-Factor?
At U 0.22, a standard 3x5 ft (15 sq ft) A-Series Contemporary Gliding Patio Door (FWGCD) opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.
Which situations make A-Series Contemporary Gliding Patio Door (FWGCD) the wrong window or door choice?
Do not specify A-Series Contemporary Gliding Patio Door (FWGCD) without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on A-Series Contemporary Gliding Patio Door (FWGCD) options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Does A-Series Contemporary Gliding Patio Door (FWGCD) meet Southern hot-climate SHGC caps (<= 0.23)?
Warm-climate homeowners have 845 Southern-approved options within A-Series Contemporary Gliding Patio Door (FWGCD) spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
Which package tier in A-Series Contemporary Gliding Patio Door (FWGCD) holds Most Efficient recognition?
Only 17 options out of 977 (1.7%) meet tighter Most Efficient U-Factor and SHGC thresholds in Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD), usually requiring triple-pane or upgraded Low-E coatings.
What federal compliance checks govern 2026 A-Series Contemporary Gliding Patio Door (FWGCD) window swaps?
Any A-Series Contemporary Gliding Patio Door (FWGCD) purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How can homeowners confirm delivered Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) units match permits?
Match the NFRC thermal sticker for code AND and line AND-N-212 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Andersen Corporation A-Series Contemporary Gliding Patio Door (FWGCD) come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)