Skip to main content
Door · Wood Frame NFRC SIE · Product Line SIE-N-9

Sierra Pacific Windows — Wood Inswing Door · Swinging Entry Door (Single)

Positioning #145/268 in certified Door, Sierra Pacific Windows Wood Inswing Door pairs Wood frame construction with 1,378 glazing options rated between 0.08 and 0.37 SHGC across Northern, North-Central, South-Central, Southern. Across 25 certified Sierra Pacific Windows product families, its thermal resistance spans 0.22 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.22
SHGC Range
0.08-0.37
Certified Options
1,378
Category Standing
#145 of 268

How does Sierra Pacific Windows Wood Inswing Door compare thermally against Door peers?

Sierra Pacific Windows Wood Inswing Door achieves a 0.22 thermal floor across Door lines, placing #145 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Wood Inswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Wood Inswing Door (U 0.22).28<=0.15650.16-0.18510.19-0.21710.22-0.24This model: U 0.22430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Wood Inswing Door Cohort StandingMin U-Factor 0.22 stands at rank #145 of 268, outperforming 39.9% of peers.Min U-Factor 0.22Rank #145 of 268 (39.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 25 certified Sierra Pacific Windows series, this Swinging Entry Door, Single offers a 0.06 U-Factor adjustment span between 0.28 entry options and 0.22 top-performing glazing. Category standing is #145/268 (tied with 16 others at 0.22, more insulating than 39.9% of Door lines).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 673 combinations qualify in the Northern Zone alongside 1,254 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-02-27. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,378 certified glazing combinations for Wood Inswing Door (NFRC SIE) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 673 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 673 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 1,254 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 1,254 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Sierra Pacific Windows produce?

Compare other active Sierra Pacific Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Sierra Pacific Windows Wood Inswing Door appear below.

What thermal performance numbers separate Sierra Pacific Windows Wood Inswing Door from peers?

EPA ENERGY STAR v7.0 records 1,378 configurations for Sierra Pacific Windows Wood Inswing Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.22 versus a 0.21 Door median. Only 0 options earn Most Efficient status.

Does Sierra Pacific Windows Wood Inswing Door qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 673 compliant Northern packages inside Wood Inswing Door, reaching down to U 0.22. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

How does a 3x5 ft Wood Inswing Door window perform under a 40 deg F temperature drop?

At U 0.22, a standard 3x5 ft (15 sq ft) Wood Inswing Door opening transfers 132.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +0.0 BTU/hr difference.

What homeowner profiles are a poor match for Sierra Pacific Windows Wood Inswing Door?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Wood Inswing Door options exceeding U 0.22. Additionally, do not order Entry Door Single-Lite (EDSL) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does Wood Inswing Door meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 1,254 Southern-certified options inside Sierra Pacific Windows Wood Inswing Door satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.37 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does Wood Inswing Door carry EPA Most Efficient certification across its lineup?

Wood Inswing Door holds zero Most Efficient entries across its 1,378 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

What 2026 federal tax credit and Lead RRP rules apply to Wood Inswing Door?

Any Wood Inswing Door purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

What permanent glass etch marks verify Wood Inswing Door after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code SIE and product line SIE-N-9, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Sierra Pacific Windows Wood Inswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)