VELUX — TLR VELUX Sun Tunnel w/Glass Top · Tubular Daylighting Device
Positioning #12/16 in certified Skylight, VELUX TLR VELUX Sun Tunnel w/Glass Top pairs Aluminum frame construction with 1 glazing option rated between 0.36 and 0.36 SHGC across Northern. Across 10 certified VELUX product families, its thermal resistance spans 0.39 to 0.39 U-Factor and the line includes 1 ENERGY STAR Most Efficient package (100.0% of line).
- Min U-Factor
- 0.39
- SHGC Range
- 0.36-0.36
- Certified Options
- 1
- Category Standing
- #12 of 16
How does VELUX TLR VELUX Sun Tunnel w/Glass Top compare thermally against Skylight peers?
VELUX TLR VELUX Sun Tunnel w/Glass Top achieves a 0.39 thermal floor across Skylight lines, placing #12 of 16 against the 0.35 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Skylight assemblies nationwide (median U 0.35), TLR VELUX Sun Tunnel w/Glass Top is 0.04 Btu/hr·ft²·°F less insulating than the 0.35 Btu/hr·ft²·°F median while keeping Aluminum frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.39-0.39.
Evaluating climate compliance across Northern separates cold-weather U <= 0.22 option from cooling-dominated glazing. Although its 0.39 floor sits above the 0.22 prescriptive Northern ceiling, 1 Northern package qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).
Data provenance links certification 2025-07-02 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 234.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1 certified glazing combinations for TLR VELUX Sun Tunnel w/Glass Top (NFRC VEL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 1 package (1 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Not Listed | <= 0.28 | <= 0.23 | 0 packages (0 Most Eff.) |
| Southern | Not Listed | <= 0.32 | <= 0.23 | 0 packages (0 Most Eff.) |
Which competing Skylight series sit closest on U-Factor?
Inspect nearby Skylight competitors clustered closest to 0.39 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| KDL Enterprises (Western Skylights) — Series AV43 Fixed Skylight | Aluminum | 0.39 | 0.28 | 36 |
| VELUX — TCC / TCR / TGC / TGR / THR / TMR | Aluminum | 0.37 | 0.27 | 4 |
| VELUX — FS | Wood | 0.37 | 0.17 | 21 |
| VELUX — TSR 010 Rigid Tube VELUX Sun Tunnel | Aluminum | 0.42 | 0.40 | 1 |
| VELUX — VS/VSE/VSS | Wood | 0.36 | 0.14 | 17 |
What other certified series does VELUX produce?
Compare other active VELUX certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
TGF / TMF VELUX Sun Tunnel w/Flex Tube
U-Factor 0.26–0.45 · 4 certified options.
TCC / TCR / TGC / TGR / THR / TMR
U-Factor 0.37–0.39 · 4 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to VELUX TLR VELUX Sun Tunnel w/Glass Top appear below.
What U-Factor and SHGC range does VELUX TLR VELUX Sun Tunnel w/Glass Top achieve?
EPA ENERGY STAR v7.0 records 1 configuration for VELUX TLR VELUX Sun Tunnel w/Glass Top covering Northern, dropping down to U 0.39 versus a 0.35 Skylight median. Only 1 option earn Most Efficient status.
How does VELUX TLR VELUX Sun Tunnel w/Glass Top satisfy Version 7.0 Northern criteria?
While VELUX TLR VELUX Sun Tunnel w/Glass Top misses the <= 0.22 prescriptive mark (floor U 0.39), 1 package still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.
How does a 3x5 ft TLR VELUX Sun Tunnel w/Glass Top window perform under a 40 deg F temperature drop?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 234.0 BTU/hr on TLR VELUX Sun Tunnel w/Glass Top's lowest-U package (0.39), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.39 transfer proportionally more energy.
When should a buyer skip VELUX TLR VELUX Sun Tunnel w/Glass Top and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on TLR VELUX Sun Tunnel w/Glass Top options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many TLR VELUX Sun Tunnel w/Glass Top glazing packages pass Southern solar-heat rules?
Southern qualification is unavailable for TLR VELUX Sun Tunnel w/Glass Top (0 qualified variants). Because its SHGC spans 0.36 to 0.36, select an alternative line explicitly rated for Southern heat rejection.
What glazing share inside TLR VELUX Sun Tunnel w/Glass Top qualifies as Most Efficient?
EPA lists 1 Most Efficient option (100.0% share) inside VELUX TLR VELUX Sun Tunnel w/Glass Top, out of 1 total Version 7.0 entries.
Can homeowners claim Form 5695 credits on VELUX TLR VELUX Sun Tunnel w/Glass Top in 2026?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current TLR VELUX Sun Tunnel w/Glass Top retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
What permanent glass etch marks verify TLR VELUX Sun Tunnel w/Glass Top after sticker removal?
Verify NFRC ID VEL and series VEL-N-22 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for VELUX TLR VELUX Sun Tunnel w/Glass Top come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)