Skip to main content
Skylight · Aluminum Frame NFRC VEL · Product Line VEL-N-22 ENERGY STAR Most Efficient Eligible

VELUX — TLR VELUX Sun Tunnel w/Glass Top · Tubular Daylighting Device

Positioning #12/16 in certified Skylight, VELUX TLR VELUX Sun Tunnel w/Glass Top pairs Aluminum frame construction with 1 glazing option rated between 0.36 and 0.36 SHGC across Northern. Across 10 certified VELUX product families, its thermal resistance spans 0.39 to 0.39 U-Factor and the line includes 1 ENERGY STAR Most Efficient package (100.0% of line).

Min U-Factor
0.39
SHGC Range
0.36-0.36
Certified Options
1
Category Standing
#12 of 16

How does VELUX TLR VELUX Sun Tunnel w/Glass Top compare thermally against Skylight peers?

VELUX TLR VELUX Sun Tunnel w/Glass Top achieves a 0.39 thermal floor across Skylight lines, placing #12 of 16 against the 0.35 category median.

Cohort Minimum U-Factor Distribution

Skylight U-Factor Distribution vs. TLR VELUX Sun Tunnel w/Glass TopHistogram of 16 ENERGY STAR v7.0 Skylight lines grouped by minimum U-Factor, highlighting bin 0.36-0.42 containing TLR VELUX Sun Tunnel w/Glass Top (U 0.39).0<=0.1500.16-0.1800.19-0.2100.22-0.2410.25-0.2730.28-0.3040.31-0.3560.36-0.42This model: U 0.392>0.42Category median min U: 0.35 (lower U = better thermal resistance)

Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).

Thermal Standing & NFRC Anatomy

TLR VELUX Sun Tunnel w/Glass Top Cohort StandingMin U-Factor 0.39 stands at rank #12 of 16, outperforming 18.8% of peers.Min U-Factor 0.39Rank #12 of 16 (18.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Skylight assemblies nationwide (median U 0.35), TLR VELUX Sun Tunnel w/Glass Top is 0.04 Btu/hr·ft²·°F less insulating than the 0.35 Btu/hr·ft²·°F median while keeping Aluminum frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.39-0.39.

Evaluating climate compliance across Northern separates cold-weather U <= 0.22 option from cooling-dominated glazing. Although its 0.39 floor sits above the 0.22 prescriptive Northern ceiling, 1 Northern package qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Data provenance links certification 2025-07-02 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 234.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1 certified glazing combinations for TLR VELUX Sun Tunnel w/Glass Top (NFRC VEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 1 package (1 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Not Listed <= 0.28 <= 0.23 0 packages (0 Most Eff.)
Southern Not Listed <= 0.32 <= 0.23 0 packages (0 Most Eff.)

Which competing Skylight series sit closest on U-Factor?

Inspect nearby Skylight competitors clustered closest to 0.39 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
KDL Enterprises (Western Skylights) — Series AV43 Fixed Skylight Aluminum 0.39 0.28 36
VELUX — TCC / TCR / TGC / TGR / THR / TMR Aluminum 0.37 0.27 4
VELUX — FS Wood 0.37 0.17 21
VELUX — TSR 010 Rigid Tube VELUX Sun Tunnel Aluminum 0.42 0.40 1
VELUX — VS/VSE/VSS Wood 0.36 0.14 17

What other certified series does VELUX produce?

Compare other active VELUX certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to VELUX TLR VELUX Sun Tunnel w/Glass Top appear below.

What U-Factor and SHGC range does VELUX TLR VELUX Sun Tunnel w/Glass Top achieve?

EPA ENERGY STAR v7.0 records 1 configuration for VELUX TLR VELUX Sun Tunnel w/Glass Top covering Northern, dropping down to U 0.39 versus a 0.35 Skylight median. Only 1 option earn Most Efficient status.

How does VELUX TLR VELUX Sun Tunnel w/Glass Top satisfy Version 7.0 Northern criteria?

While VELUX TLR VELUX Sun Tunnel w/Glass Top misses the <= 0.22 prescriptive mark (floor U 0.39), 1 package still earn Northern certification via solar-gain trade-offs allowing U 0.23-0.24 at SHGC >= 0.35 or U 0.25-0.26 at SHGC >= 0.40.

How does a 3x5 ft TLR VELUX Sun Tunnel w/Glass Top window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 234.0 BTU/hr on TLR VELUX Sun Tunnel w/Glass Top's lowest-U package (0.39), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.39 transfer proportionally more energy.

When should a buyer skip VELUX TLR VELUX Sun Tunnel w/Glass Top and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on TLR VELUX Sun Tunnel w/Glass Top options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many TLR VELUX Sun Tunnel w/Glass Top glazing packages pass Southern solar-heat rules?

Southern qualification is unavailable for TLR VELUX Sun Tunnel w/Glass Top (0 qualified variants). Because its SHGC spans 0.36 to 0.36, select an alternative line explicitly rated for Southern heat rejection.

What glazing share inside TLR VELUX Sun Tunnel w/Glass Top qualifies as Most Efficient?

EPA lists 1 Most Efficient option (100.0% share) inside VELUX TLR VELUX Sun Tunnel w/Glass Top, out of 1 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on VELUX TLR VELUX Sun Tunnel w/Glass Top in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current TLR VELUX Sun Tunnel w/Glass Top retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify TLR VELUX Sun Tunnel w/Glass Top after sticker removal?

Verify NFRC ID VEL and series VEL-N-22 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for VELUX TLR VELUX Sun Tunnel w/Glass Top come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros