Skip to main content
Skylight · Aluminum Frame NFRC VEL · Product Line VEL-N-11

VELUX — TSR 010 Rigid Tube VELUX Sun Tunnel · Tubular Daylighting Device

With a minimum U-Factor of 0.42—+0.07 compared against the 0.35 Skylight median—VELUX TSR 010 Rigid Tube VELUX Sun Tunnel spans 1 tested option across Northern up to 0.42 U-Factor. Carrying NFRC CPD code VEL, the Aluminum assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.40 and 0.40.

Min U-Factor
0.42
SHGC Range
0.40-0.40
Certified Options
1
Category Standing
#14 of 16

How does VELUX TSR 010 Rigid Tube VELUX Sun Tunnel compare thermally against Skylight peers?

VELUX TSR 010 Rigid Tube VELUX Sun Tunnel achieves a 0.42 thermal floor across Skylight lines, placing #14 of 16 against the 0.35 category median.

Cohort Minimum U-Factor Distribution

Skylight U-Factor Distribution vs. TSR 010 Rigid Tube VELUX Sun TunnelHistogram of 16 ENERGY STAR v7.0 Skylight lines grouped by minimum U-Factor, highlighting bin 0.36-0.42 containing TSR 010 Rigid Tube VELUX Sun Tunnel (U 0.42).0<=0.1500.16-0.1800.19-0.2100.22-0.2410.25-0.2730.28-0.3040.31-0.3560.36-0.42This model: U 0.422>0.42Category median min U: 0.35 (lower U = better thermal resistance)

Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).

Thermal Standing & NFRC Anatomy

TSR 010 Rigid Tube VELUX Sun Tunnel Cohort StandingMin U-Factor 0.42 stands at rank #14 of 16, outperforming 12.5% of peers.Min U-Factor 0.42Rank #14 of 16 (12.5% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across TSR 010 Rigid Tube VELUX Sun Tunnel spans 1 NFRC test record (VEL), ranking #14 of 16 Skylight families (more insulating than 12.5% of Skylight lines). Its 0.42 thermal floor compares at +0.19 against the Aluminum median (0.23).

Zone eligibility across EPA boundaries reaches 1 market (Northern). Although its 0.42 floor sits above the 0.22 prescriptive Northern ceiling, 1 Northern package qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Lifecycle documentation anchors VEL to 2024-02-26 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 252.0 BTU/hr conductive loss (+90.9% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1 certified glazing combinations for TSR 010 Rigid Tube VELUX Sun Tunnel (NFRC VEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 1 package (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Not Listed <= 0.28 <= 0.23 0 packages (0 Most Eff.)
Southern Not Listed <= 0.32 <= 0.23 0 packages (0 Most Eff.)

Which competing Skylight series sit closest on U-Factor?

Inspect nearby Skylight competitors clustered closest to 0.42 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
VELUX — TZR / TZRL / TZRQ 014 Aluminum 0.43 0.35 2
KDL Enterprises (Western Skylights) — Series AV43 Fixed Skylight Aluminum 0.39 0.28 36
VELUX — TLR VELUX Sun Tunnel w/Glass Top Aluminum 0.39 0.36 1
VELUX — VCM/VCE/VCS Aluminum / Wood 0.45 0.15 33
VELUX — TCC / TCR / TGC / TGR / THR / TMR Aluminum 0.37 0.27 4

What other certified series does VELUX produce?

Compare other active VELUX certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to VELUX TSR 010 Rigid Tube VELUX Sun Tunnel appear below.

How efficient is VELUX TSR 010 Rigid Tube VELUX Sun Tunnel compared with peer Skylight models?

Testing puts VELUX TSR 010 Rigid Tube VELUX Sun Tunnel at rank #14 of 16 Skylight entries with U 0.42 to 0.42 across 1 configuration. Solar heat gain ranges between 0.40 and 0.40 across Northern.

Can homeowners install TSR 010 Rigid Tube VELUX Sun Tunnel in cold Northern ENERGY STAR counties?

Because TSR 010 Rigid Tube VELUX Sun Tunnel starts at 0.42 U-Factor, it exceeds the 0.22 prescriptive ceiling. Instead, 1 Northern package qualify through EPA Equivalent Energy Performance rules pairing U 0.23-0.26 with higher SHGC (>= 0.35 or >= 0.40).

How does a 3x5 ft TSR 010 Rigid Tube VELUX Sun Tunnel window perform under a 40 deg F temperature drop?

Using NFRC VEL U-Factor 0.42, a 15 sq ft Tubular Daylighting Device (TDDY) assembly conducts 252.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+120.0 BTU/hr margin).

What are the practical limitations of specifying TSR 010 Rigid Tube VELUX Sun Tunnel?

Skip TSR 010 Rigid Tube VELUX Sun Tunnel if local historic preservation boards prohibit Aluminum profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on TSR 010 Rigid Tube VELUX Sun Tunnel options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in TSR 010 Rigid Tube VELUX Sun Tunnel?

Southern qualification is unavailable for TSR 010 Rigid Tube VELUX Sun Tunnel (0 qualified variants). Because its SHGC spans 0.40 to 0.40, select an alternative line explicitly rated for Southern heat rejection.

Does TSR 010 Rigid Tube VELUX Sun Tunnel carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 1 TSR 010 Rigid Tube VELUX Sun Tunnel options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Can homeowners claim Form 5695 credits on VELUX TSR 010 Rigid Tube VELUX Sun Tunnel in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current TSR 010 Rigid Tube VELUX Sun Tunnel retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC VEL and product line VEL-N-11 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code VEL and product line VEL-N-11, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for VELUX TSR 010 Rigid Tube VELUX Sun Tunnel come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros