Skip to main content
Skylight · Aluminum / Wood Frame NFRC VEL · Product Line VEL-N-21

VELUX — VCM/VCE/VCS · Skylight

Positioning #16/16 in certified Skylight, VELUX VCM/VCE/VCS pairs Aluminum / Wood frame construction with 33 glazing options rated between 0.15 and 0.24 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified VELUX product families, its thermal resistance spans 0.45 to 0.50 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.45
SHGC Range
0.15-0.24
Certified Options
33
Category Standing
#16 of 16

How does VELUX VCM/VCE/VCS compare thermally against Skylight peers?

VELUX VCM/VCE/VCS achieves a 0.45 thermal floor across Skylight lines, placing #16 of 16 against the 0.35 category median.

Cohort Minimum U-Factor Distribution

Skylight U-Factor Distribution vs. VCM/VCE/VCSHistogram of 16 ENERGY STAR v7.0 Skylight lines grouped by minimum U-Factor, highlighting bin >0.42 containing VCM/VCE/VCS (U 0.45).0<=0.1500.16-0.1800.19-0.2100.22-0.2410.25-0.2730.28-0.3040.31-0.3560.36-0.422>0.42This model: U 0.45Category median min U: 0.35 (lower U = better thermal resistance)

Minimum U-Factor across 16 EPA-certified Skylight lines (category median: 0.35).

Thermal Standing & NFRC Anatomy

VCM/VCE/VCS Cohort StandingMin U-Factor 0.45 stands at rank #16 of 16, outperforming 2.0% of peers.Min U-Factor 0.45Rank #16 of 16 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Aluminum / Wood cohort (0.33 median U-Factor), VCM/VCE/VCS reaches 0.45 on its lowest-conductivity package — #2 of 2 in Aluminum / Wood, lowest-ranked of 2 Aluminum / Wood lines (+0.12 vs Aluminum / Wood peers). Pairing NFRC ID VEL across multi-pane fills shifts U-Factor from 0.50 down toward 0.45.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Although its 0.45 floor sits above the 0.22 prescriptive Northern ceiling, 4 Northern packages qualify under EPA Equivalent Energy Performance solar-gain trade-offs (SHGC >= 0.35 or >= 0.40).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 270.0 BTU/hr (+104.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-20 and cert timestamp 2024-01-10.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 33 certified glazing combinations for VCM/VCE/VCS (NFRC VEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Equiv. Path <= 0.22 >= 0.17 4 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 33 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 33 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 33 packages (0 Most Eff.)

Which competing Skylight series sit closest on U-Factor?

Inspect nearby Skylight competitors clustered closest to 0.45 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
VELUX — TZR / TZRL / TZRQ 014 Aluminum 0.43 0.35 2
VELUX — TSR 010 Rigid Tube VELUX Sun Tunnel Aluminum 0.42 0.40 1
KDL Enterprises (Western Skylights) — Series AV43 Fixed Skylight Aluminum 0.39 0.28 36
VELUX — TLR VELUX Sun Tunnel w/Glass Top Aluminum 0.39 0.36 1
VELUX — FS Wood 0.37 0.17 21

What other certified series does VELUX produce?

Compare other active VELUX certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to VELUX VCM/VCE/VCS appear below.

How efficient is VELUX VCM/VCE/VCS compared with peer Skylight models?

EPA ENERGY STAR v7.0 records 33 configurations for VELUX VCM/VCE/VCS covering Northern, North-Central, South-Central, Southern, dropping down to U 0.45 versus a 0.35 Skylight median. Only 0 options earn Most Efficient status.

Which glazing options in VELUX VCM/VCE/VCS meet Northern climate limits?

Prescriptive Northern approval ends at U <= 0.22, above VCM/VCE/VCS's 0.45 minimum. However, 4 Northern packages pass EPA Equivalent compliance by pairing higher solar gain (SHGC >= 0.35 or 0.40) with <= 0.3 cfm/ft2 air leakage.

How does a 3x5 ft VCM/VCE/VCS window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 270.0 BTU/hr on VCM/VCE/VCS's lowest-U package (0.45), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.50 transfer proportionally more energy.

When should a buyer skip VELUX VCM/VCE/VCS and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on VCM/VCE/VCS options exceeding U 0.22. Verify whether your municipal code restricts Aluminum / Wood frames in wildfire or historic zones.

How many VCM/VCE/VCS glazing packages pass Southern solar-heat rules?

Yes. 33 Southern-certified options inside VELUX VCM/VCE/VCS satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.24 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many VELUX VCM/VCE/VCS variants earn ENERGY STAR Most Efficient?

No. Zero of the 33 configurations in VELUX VCM/VCE/VCS hold ENERGY STAR Most Efficient status; this line meets standard Version 7.0 regional efficiency limits only.

What federal compliance checks govern 2026 VCM/VCE/VCS window swaps?

Any VCM/VCE/VCS purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC VEL and product line VEL-N-21 on delivery?

Confirm both the paper NFRC label and permanent corner glass etch match line VEL-N-21 and NFRC ID VEL before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for VELUX VCM/VCE/VCS come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros