Skip to main content
Window · Vinyl Frame NFRC VYW · Product Line VYW-A-55

Vytex Corporation — Georgetown Elite Slider · Double Slider

Across 18 Vytex Corporation certified families, Georgetown Elite Slider supplies 28 Double Slider configurations starting at 0.23 U-Factor and 0.19 SHGC for North-Central, South-Central, Southern, reaching up to 0.30 U-Factor and 0.28 SHGC. Its thermal floor ranks #936 of 1,352 category entries—0.03 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.23
SHGC Range
0.19-0.28
Certified Options
28
Category Standing
#936 of 1,352

How does Vytex Corporation Georgetown Elite Slider compare thermally against Window peers?

Vytex Corporation Georgetown Elite Slider achieves a 0.23 thermal floor across Window lines, placing #936 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Georgetown Elite SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing Georgetown Elite Slider (U 0.23).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.231460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Georgetown Elite Slider Cohort StandingMin U-Factor 0.23 stands at rank #936 of 1,352, outperforming 23.6% of peers.Min U-Factor 0.23Rank #936 of 1,352 (23.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Georgetown Elite Slider spans 28 NFRC test records (VYW), ranking #936 of 1,352 Window families (tied with 97 others at 0.23, more insulating than 23.6% of Window lines). Its 0.23 thermal floor compares at +0.04 against the Vinyl median (0.19).

Regional qualification covers North-Central, South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward North-Central, South-Central, Southern markets where low SHGC down to 0.19 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 138.0 BTU/hr (+4.5% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-07-17.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 28 certified glazing combinations for Georgetown Elite Slider (NFRC VYW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 10 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 16 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 24 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.23 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vytex Corporation produce?

Compare other active Vytex Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vytex Corporation Georgetown Elite Slider appear below.

Where does Vytex Corporation Georgetown Elite Slider stand thermally among ENERGY STAR Window lines?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, Vytex Corporation Georgetown Elite Slider offers 28 Version 7.0 configurations from U 0.23 up to 0.30, posting +0.03 against the Window median of 0.20 with 0 Most Efficient picks.

How does Vytex Corporation Georgetown Elite Slider satisfy Version 7.0 Northern criteria?

No. Because Georgetown Elite Slider reaches only 0.23 U-Factor with 0 Northern combinations, it is not approved for ENERGY STAR Northern counties. Specify this Vinyl line strictly across North-Central, South-Central, Southern cooling or mixed markets.

What conductive BTU/hr difference separates Georgetown Elite Slider from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.23 U-Factor yields 138.0 BTU/hr conductive transfer (+4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Georgetown Elite Slider the wrong window or door choice?

Do not specify Georgetown Elite Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Georgetown Elite Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does Georgetown Elite Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Across North-Central, South-Central, Southern, 24 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Vytex Corporation Georgetown Elite Slider, while total line SHGC reaches 0.28 in colder packages.

How many Vytex Corporation Georgetown Elite Slider variants earn ENERGY STAR Most Efficient?

All 28 Georgetown Elite Slider listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Do 2026 Georgetown Elite Slider installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Vytex Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Georgetown Elite Slider after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.23-0.30, SHGC 0.19-0.28) against permit drawings for line VYW-A-55. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vytex Corporation Georgetown Elite Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros