Skip to main content
Window · Vinyl Frame NFRC HGB · Product Line HGB-K-10 ENERGY STAR Most Efficient Eligible

WeatherBarr Windows and Doors — 4000 / 5000 Awning · Awning (Projected)

WeatherBarr Windows and Doors engineered the 4000 / 5000 Awning Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 237 glass-spacer combinations from 0.22 to 0.32 U-Factor and 0.14 to 0.24 SHGC. Relative to other Vinyl models tracked under NFRC HGB, its minimum U-Factor is 0.03 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.14-0.24
Certified Options
237
Category Standing
#831 of 1,352

How does WeatherBarr Windows and Doors 4000 / 5000 Awning compare thermally against Window peers?

WeatherBarr Windows and Doors 4000 / 5000 Awning achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 4000 / 5000 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 4000 / 5000 Awning (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

4000 / 5000 Awning Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 4000 / 5000 Awning spans 237 NFRC test records (HGB), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.14 to 0.24) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 4 configurations meet ENERGY STAR Most Efficient criteria while 1 combination satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-08 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 237 certified glazing combinations for 4000 / 5000 Awning (NFRC HGB) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 1 package (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 123 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 190 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 231 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does WeatherBarr Windows and Doors produce?

Compare other active WeatherBarr Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to WeatherBarr Windows and Doors 4000 / 5000 Awning appear below.

Where does WeatherBarr Windows and Doors 4000 / 5000 Awning stand thermally among ENERGY STAR Window lines?

WeatherBarr Windows and Doors 4000 / 5000 Awning spans 237 certified configurations with U-Factors between 0.22 and 0.32 and SHGC values from 0.14 to 0.24. Ranked #831 of 1,352 Window families, it carries 4 Most Efficient options.

Which glazing options in WeatherBarr Windows and Doors 4000 / 5000 Awning meet Northern climate limits?

Prescriptive Northern compliance covers 1 4000 / 5000 Awning package (U floor 0.22, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What conductive BTU/hr difference separates 4000 / 5000 Awning from the 0.22 Northern rule?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 132.0 BTU/hr on 4000 / 5000 Awning's lowest-U package (0.22), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

Which situations make 4000 / 5000 Awning the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 4000 / 5000 Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 4000 / 5000 Awning?

Yes. 231 Southern-certified options inside WeatherBarr Windows and Doors 4000 / 5000 Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.24 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in 4000 / 5000 Awning holds Most Efficient recognition?

EPA lists 4 Most Efficient options (1.7% share) inside WeatherBarr Windows and Doors 4000 / 5000 Awning, out of 237 total Version 7.0 entries.

Do 2026 4000 / 5000 Awning installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 WeatherBarr Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered WeatherBarr Windows and Doors 4000 / 5000 Awning units match permits?

Inspectors match the temporary NFRC sticker (U 0.22-0.32, SHGC 0.14-0.24) against permit drawings for line HGB-K-10. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for WeatherBarr Windows and Doors 4000 / 5000 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros