Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-44

Associated Materials, Inc. — 0704 Picture Window · Picture Window

Across 34 Associated Materials, Inc. certified families, 0704 Picture Window supplies 264 Picture Window configurations starting at 0.22 U-Factor and 0.11 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.56 SHGC. Its thermal floor ranks #831 of 1,352 category entries—0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.22
SHGC Range
0.11-0.56
Certified Options
264
Category Standing
#831 of 1,352

How does Associated Materials, Inc. 0704 Picture Window compare thermally against Window peers?

Associated Materials, Inc. 0704 Picture Window achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 0704 Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.22-0.24 containing 0704 Picture Window (U 0.22).249<=0.153140.16-0.182670.19-0.213430.22-0.24This model: U 0.221460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

0704 Picture Window Cohort StandingMin U-Factor 0.22 stands at rank #831 of 1,352, outperforming 30.8% of peers.Min U-Factor 0.22Rank #831 of 1,352 (30.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 0704 Picture Window reaches 0.22 on its lowest-conductivity package — #640 of 1,009 in Vinyl, tied with 75 others at 0.22, more insulating than 29.1% of Vinyl lines (+0.03 vs Vinyl peers). Pairing NFRC ID ASO across multi-pane fills shifts U-Factor from 0.32 down toward 0.22.

Climate coverage for Associated Materials, Inc. 0704 Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 33 combinations qualify in the Northern Zone alongside 217 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-11-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.22 conducts 132.0 BTU/hr (matching the 0.22 Northern baseline).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 264 certified glazing combinations for 0704 Picture Window (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 33 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 37 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 96 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 217 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. 0704 Picture Window appear below.

Where does Associated Materials, Inc. 0704 Picture Window stand thermally among ENERGY STAR Window lines?

Across 264 tested NFRC glazing configurations, Associated Materials, Inc. 0704 Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.22 minimum U-Factor and 0.11-0.56 SHGC band. It places #831 among 1,352 Window series—more insulating than 30.8%.

Is 0704 Picture Window approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 33 0704 Picture Window packages (U floor 0.22, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How much winter heat loss does 0704 Picture Window conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.22 U-Factor yields 132.0 BTU/hr conductive transfer (+0.0% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Associated Materials, Inc. 0704 Picture Window and compare alternatives?

Do not specify 0704 Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 0704 Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is 0704 Picture Window suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 217 Southern-approved options within 0704 Picture Window spanning SHGC down to 0.11. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in 0704 Picture Window holds Most Efficient recognition?

ENERGY STAR Most Efficient designation is absent across all 264 0704 Picture Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

What 2026 federal tax credit and Lead RRP rules apply to 0704 Picture Window?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How do building inspectors verify 0704 Picture Window glass specs on job sites?

Verify NFRC ID ASO and series ASO-A-44 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. 0704 Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros