WeatherBarr Windows and Doors — 4100/5100 Single Vent Casement · Casement Windows
WeatherBarr Windows and Doors 4100/5100 Single Vent Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.22 across 234 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #831 of 1,352 in Window, its thermal floor is 0.02 Btu/hr·ft²·°F less insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.24.
- Min U-Factor
- 0.22
- SHGC Range
- 0.14-0.24
- Certified Options
- 234
- Category Standing
- #831 of 1,352
How does WeatherBarr Windows and Doors 4100/5100 Single Vent Casement compare thermally against Window peers?
WeatherBarr Windows and Doors 4100/5100 Single Vent Casement achieves a 0.22 thermal floor across Window lines, placing #831 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across 4100/5100 Single Vent Casement spans 234 NFRC test records (HGB), ranking #831 of 1,352 Window families (tied with 104 others at 0.22, more insulating than 30.8% of Window lines). Its 0.22 thermal floor compares at +0.03 against the Vinyl median (0.19).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 5 configurations meet ENERGY STAR Most Efficient criteria while 2 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.22 U-Factor yields 132.0 BTU/hr transfer (matching the 0.22 Northern baseline). Manufacturer filing reflects 2018-01-10 licensing and 2024-02-16 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 234 certified glazing combinations for 4100/5100 Single Vent Casement (NFRC HGB) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 2 packages (0 Most Eff.) |
| North-Central | Certified | <= 0.25 | <= 0.40 | 123 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 189 packages (0 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 228 packages (5 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.22 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| ABI Windows LLC — 500 Fixed Window | Vinyl | 0.22 | 0.11 | 244 |
| Windsor Windows and Doors — Next Dimension Signature Sliding Patio Door Fixed | Vinyl | 0.22 | 0.16 | 248 |
| Thermo-Tech Windows — 7400 Horizontal Slider | Vinyl | 0.22 | 0.17 | 263 |
| Associated Materials, Inc. — 0704 Picture Window | Vinyl | 0.22 | 0.11 | 264 |
| Kasson and Keller — 220/2200 Double Hung | Vinyl | 0.22 | 0.19 | 185 |
What other certified series does WeatherBarr Windows and Doors produce?
Compare other active WeatherBarr Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Cornerstone/Heritage Picture Window
U-Factor 0.19–0.32 · 710 certified options.
TrustGard Direct Set Picture Window
U-Factor 0.19–0.32 · 213 certified options.
5000 Replacement Casement Picture Window
U-Factor 0.21–0.32 · 244 certified options.
Cornerstone/Heritage Horizontal Slider
U-Factor 0.21–0.32 · 947 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to WeatherBarr Windows and Doors 4100/5100 Single Vent Casement appear below.
What U-Factor and SHGC range does WeatherBarr Windows and Doors 4100/5100 Single Vent Casement achieve?
WeatherBarr Windows and Doors 4100/5100 Single Vent Casement spans 234 certified configurations with U-Factors between 0.22 and 0.32 and SHGC values from 0.14 to 0.24. Ranked #831 of 1,352 Window families, it carries 5 Most Efficient options.
Which glazing options in WeatherBarr Windows and Doors 4100/5100 Single Vent Casement meet Northern climate limits?
Yes. 2 packages in WeatherBarr Windows and Doors 4100/5100 Single Vent Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.
What BTU/hr heat transfer results from 4100/5100 Single Vent Casement's 0.22 minimum U-Factor?
Using NFRC HGB U-Factor 0.22, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 132.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+0.0 BTU/hr margin).
Who should NOT choose WeatherBarr Windows and Doors 4100/5100 Single Vent Casement for a residential project?
Do not specify 4100/5100 Single Vent Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 4100/5100 Single Vent Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
How many 4100/5100 Single Vent Casement glazing packages pass Southern solar-heat rules?
Across Northern, North-Central, South-Central, Southern, 228 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside WeatherBarr Windows and Doors 4100/5100 Single Vent Casement, while total line SHGC reaches 0.24 in colder packages.
Does 4100/5100 Single Vent Casement carry EPA Most Efficient certification across its lineup?
No. Exactly 5 of 234 configurations (2.1%) earn ENERGY STAR Most Efficient status in 4100/5100 Single Vent Casement; the remaining standard v7.0 options pass base zone limits only.
What federal compliance checks govern 2026 4100/5100 Single Vent Casement window swaps?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do building inspectors verify 4100/5100 Single Vent Casement glass specs on job sites?
Match the NFRC thermal sticker for code HGB and line HGB-K-9 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for WeatherBarr Windows and Doors 4100/5100 Single Vent Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)