Skip to main content
Door · Aluminum Frame NFRC WIG · Product Line WIG-A-37 ENERGY STAR Most Efficient Eligible

Western Architectural Openings — 7650 Sliding Door · Sliding Patio Door

Positioning #116/268 in certified Door, Western Architectural Openings 7650 Sliding Door pairs Aluminum frame construction with 394 glazing options rated between 0.10 and 0.40 SHGC across Northern, North-Central, South-Central, Southern. Across 2 certified Western Architectural Openings product families, its thermal resistance spans 0.20 to 0.28 U-Factor and the line includes 140 ENERGY STAR Most Efficient packages (35.5% of line).

Min U-Factor
0.20
SHGC Range
0.10-0.40
Certified Options
394
Category Standing
#116 of 268

How does Western Architectural Openings 7650 Sliding Door compare thermally against Door peers?

Western Architectural Openings 7650 Sliding Door achieves a 0.20 thermal floor across Door lines, placing #116 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 7650 Sliding DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 7650 Sliding Door (U 0.20).28<=0.15650.16-0.18510.19-0.21This model: U 0.20710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

7650 Sliding Door Cohort StandingMin U-Factor 0.20 stands at rank #116 of 268, outperforming 50.7% of peers.Min U-Factor 0.20Rank #116 of 268 (50.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Western Architectural Openings 7650 Sliding Door at rank #116 of 268 (tied with 16 others at 0.20, more insulating than 50.7% of Door lines, top 49.3%; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.10-0.40 band.

Mapping NFRC SHGC values (0.10 to 0.40) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 140 configurations meet ENERGY STAR Most Efficient criteria while 360 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-03-05 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 394 certified glazing combinations for 7650 Sliding Door (NFRC WIG) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 360 packages (13 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 360 packages (40 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 286 packages (31 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 286 packages (131 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Western Architectural Openings produce?

Compare other active Western Architectural Openings certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Western Architectural Openings 7650 Sliding Door appear below.

What thermal performance numbers separate Western Architectural Openings 7650 Sliding Door from peers?

EPA ENERGY STAR v7.0 records 394 configurations for Western Architectural Openings 7650 Sliding Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.21 Door median. Only 140 options earn Most Efficient status.

Can homeowners install 7650 Sliding Door in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 360 7650 Sliding Door packages (U floor 0.20, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from 7650 Sliding Door's 0.20 minimum U-Factor?

At U 0.20, a standard 3x5 ft (15 sq ft) 7650 Sliding Door opening transfers 120.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -12.0 BTU/hr difference.

Which situations make 7650 Sliding Door the wrong window or door choice?

Skip 7650 Sliding Door if local historic preservation boards prohibit Aluminum profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 7650 Sliding Door options exceeding U 0.22.

Is 7650 Sliding Door suitable for sunbelt cooling-dominated homes?

Yes, 7650 Sliding Door holds 286 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.10 SHGC in cooling climates.

What glazing share inside 7650 Sliding Door qualifies as Most Efficient?

Within 7650 Sliding Door, 35.5% (140 of 394) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Can homeowners claim Form 5695 credits on Western Architectural Openings 7650 Sliding Door in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 7650 Sliding Door installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC WIG and product line WIG-A-37 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code WIG and product line WIG-A-37, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Western Architectural Openings 7650 Sliding Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros