Skip to main content
Door · Wood Frame NFRC PEL · Product Line PEL-N-238 ENERGY STAR Most Efficient Eligible

Pella Corporation — Pella Architect Contemporary Clad Sliding Door · Sliding Patio Door

Across 39 Pella Corporation certified families, Pella Architect Contemporary Clad Sliding Door supplies 223 Sliding Patio Door configurations starting at 0.20 U-Factor and 0.11 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.40 SHGC. Its thermal floor ranks #116 of 268 category entries—0.01 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.11-0.40
Certified Options
223
Category Standing
#116 of 268

How does Pella Corporation Pella Architect Contemporary Clad Sliding Door compare thermally against Door peers?

Pella Corporation Pella Architect Contemporary Clad Sliding Door achieves a 0.20 thermal floor across Door lines, placing #116 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. Pella Architect Contemporary Clad Sliding DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Pella Architect Contemporary Clad Sliding Door (U 0.20).28<=0.15650.16-0.18510.19-0.21This model: U 0.20710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

Pella Architect Contemporary Clad Sliding Door Cohort StandingMin U-Factor 0.20 stands at rank #116 of 268, outperforming 50.7% of peers.Min U-Factor 0.20Rank #116 of 268 (50.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 268 ENERGY STAR v7.0 Door lines places Pella Corporation Pella Architect Contemporary Clad Sliding Door at rank #116 of 268 (tied with 16 others at 0.20, more insulating than 50.7% of Door lines, top 49.3%; cohort median 0.21). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.11-0.40 band.

Mapping NFRC SHGC values (0.11 to 0.40) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 14 configurations meet ENERGY STAR Most Efficient criteria while 137 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-01-17 and FENSTAR license 2018-02-20 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 223 certified glazing combinations for Pella Architect Contemporary Clad Sliding Door (NFRC PEL) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 137 packages (1 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 137 packages (2 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 168 packages (1 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 168 packages (13 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Pella Corporation produce?

Compare other active Pella Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Pella Corporation Pella Architect Contemporary Clad Sliding Door appear below.

Where does Pella Corporation Pella Architect Contemporary Clad Sliding Door stand thermally among ENERGY STAR Door lines?

EPA ENERGY STAR v7.0 records 223 configurations for Pella Corporation Pella Architect Contemporary Clad Sliding Door covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.21 Door median. Only 14 options earn Most Efficient status.

Can homeowners install Pella Architect Contemporary Clad Sliding Door in cold Northern ENERGY STAR counties?

Pella Corporation Pella Architect Contemporary Clad Sliding Door supplies 137 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

What conductive BTU/hr difference separates Pella Architect Contemporary Clad Sliding Door from the 0.22 Northern rule?

Using NFRC PEL U-Factor 0.20, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 120.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-12.0 BTU/hr margin).

Which situations make Pella Architect Contemporary Clad Sliding Door the wrong window or door choice?

Do not specify Pella Architect Contemporary Clad Sliding Door without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Pella Architect Contemporary Clad Sliding Door options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in Pella Architect Contemporary Clad Sliding Door?

Yes, Pella Architect Contemporary Clad Sliding Door holds 168 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.11 SHGC in cooling climates.

Does Pella Architect Contemporary Clad Sliding Door carry EPA Most Efficient certification across its lineup?

Only 14 options out of 223 (6.3%) meet tighter Most Efficient U-Factor and SHGC thresholds in Pella Corporation Pella Architect Contemporary Clad Sliding Door, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect Pella Architect Contemporary Clad Sliding Door?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Pella Corporation upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify Pella Architect Contemporary Clad Sliding Door glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.20-0.28, SHGC 0.11-0.40) against permit drawings for line PEL-N-238. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Pella Corporation Pella Architect Contemporary Clad Sliding Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)