Skip to main content
Door · Wood Frame NFRC AND · Product Line AND-N-61 ENERGY STAR Most Efficient Eligible

Andersen Corporation — 200 Series Narroline® Gliding Patio Door · Sliding Patio Door

Andersen Corporation engineered the 200 Series Narroline® Gliding Patio Door Sliding Patio Door line for Northern, North-Central, South-Central, Southern, certifying 617 glass-spacer combinations from 0.20 to 0.28 U-Factor and 0.13 to 0.40 SHGC. Relative to other Wood models tracked under NFRC AND, its minimum U-Factor is 0.01 Btu/hr·ft²·°F more insulating than the 0.21 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.13-0.40
Certified Options
617
Category Standing
#116 of 268

How does Andersen Corporation 200 Series Narroline® Gliding Patio Door compare thermally against Door peers?

Andersen Corporation 200 Series Narroline® Gliding Patio Door achieves a 0.20 thermal floor across Door lines, placing #116 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. 200 Series Narroline® Gliding Patio DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 200 Series Narroline® Gliding Patio Door (U 0.20).28<=0.15650.16-0.18510.19-0.21This model: U 0.20710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

200 Series Narroline® Gliding Patio Door Cohort StandingMin U-Factor 0.20 stands at rank #116 of 268, outperforming 50.7% of peers.Min U-Factor 0.20Rank #116 of 268 (50.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 200 Series Narroline® Gliding Patio Door spans 617 NFRC test records (AND), ranking #116 of 268 Door families (tied with 16 others at 0.20, more insulating than 50.7% of Door lines, top 49.3%). Its 0.20 thermal floor compares at -0.01 against the Wood median (0.21).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 76 configurations meet ENERGY STAR Most Efficient criteria while 453 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors AND to 2026-03-12 certification (FENSTAR issued 2019-01-08). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 120.0 BTU/hr conductive loss (-9.1% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 617 certified glazing combinations for 200 Series Narroline® Gliding Patio Door (NFRC AND) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 453 packages (14 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 453 packages (31 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 444 packages (21 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 444 packages (66 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Andersen Corporation produce?

Compare other active Andersen Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Andersen Corporation 200 Series Narroline® Gliding Patio Door appear below.

How efficient is Andersen Corporation 200 Series Narroline® Gliding Patio Door compared with peer Door models?

Andersen Corporation 200 Series Narroline® Gliding Patio Door spans 617 certified configurations with U-Factors between 0.20 and 0.28 and SHGC values from 0.13 to 0.40. Ranked #116 of 268 Door families, it carries 76 Most Efficient options.

Is 200 Series Narroline® Gliding Patio Door approved for Northern Zone heating climates?

Cold-climate buyers get 453 compliant Northern packages inside 200 Series Narroline® Gliding Patio Door, reaching down to U 0.20. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

What conductive BTU/hr difference separates 200 Series Narroline® Gliding Patio Door from the 0.22 Northern rule?

Using NFRC AND U-Factor 0.20, a 15 sq ft Sliding Glass Door (DDSG) assembly conducts 120.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-12.0 BTU/hr margin).

Who should NOT choose Andersen Corporation 200 Series Narroline® Gliding Patio Door for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 200 Series Narroline® Gliding Patio Door options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install Andersen Corporation 200 Series Narroline® Gliding Patio Door in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 444 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Andersen Corporation 200 Series Narroline® Gliding Patio Door, while total line SHGC reaches 0.40 in colder packages.

How many Andersen Corporation 200 Series Narroline® Gliding Patio Door variants earn ENERGY STAR Most Efficient?

No. Exactly 76 of 617 configurations (12.3%) earn ENERGY STAR Most Efficient status in 200 Series Narroline® Gliding Patio Door; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect 200 Series Narroline® Gliding Patio Door?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify 200 Series Narroline® Gliding Patio Door after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code AND and product line AND-N-61, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Andersen Corporation 200 Series Narroline® Gliding Patio Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros