Skip to main content
Window · Vinyl Frame NFRC WMI · Product Line WMI-K-30

Window Mart — 8700 Awning · Awning (Projected)

Positioning #1,320/1,352 in certified Window, Window Mart 8700 Awning pairs Vinyl frame construction with 2 glazing options rated between 0.17 and 0.19 SHGC across South-Central, Southern. Across 6 certified Window Mart product families, its thermal resistance spans 0.28 to 0.28 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.28
SHGC Range
0.17-0.19
Certified Options
2
Category Standing
#1,320 of 1,352

How does Window Mart 8700 Awning compare thermally against Window peers?

Window Mart 8700 Awning achieves a 0.28 thermal floor across Window lines, placing #1,320 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 8700 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing 8700 Awning (U 0.28).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.30This model: U 0.2820.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

8700 Awning Cohort StandingMin U-Factor 0.28 stands at rank #1,320 of 1,352, outperforming 2.0% of peers.Min U-Factor 0.28Rank #1,320 of 1,352 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Window Mart 8700 Awning standing at #1,320 of 1,352 certified Window product series, tied with 23 others at 0.28, more insulating than 0.7% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.09 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 2 markets (South-Central, Southern). Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.17 lowers cooling load.

Data provenance links certification 2024-04-10 and FENSTAR license 2018-05-10 inside EPA Version 7.0 tables. Heat transfer computes to 168.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2 certified glazing combinations for 8700 Awning (NFRC WMI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 2 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 2 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Duke Vinyl Windows — Marquis Single Hung Vinyl 0.28 0.20 6
Phos Window — 1400 Picture Window Vinyl 0.28 0.21 8
Duke Vinyl Windows — Marquis Double Hung Vinyl 0.28 0.19 12
Duke Vinyl Windows — Marquis Horizontal Slider Vinyl 0.28 0.19 12
All America Windows LLC — 1900 Series Single Hung Vinyl 0.28 0.19 36

What other certified series does Window Mart produce?

Compare other active Window Mart certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Window Mart 8700 Awning appear below.

What U-Factor and SHGC range does Window Mart 8700 Awning achieve?

Window Mart 8700 Awning spans 2 certified configurations with U-Factors between 0.28 and 0.28 and SHGC values from 0.17 to 0.19. Ranked #1,320 of 1,352 Window families, it carries 0 Most Efficient options.

How does Window Mart 8700 Awning satisfy Version 7.0 Northern criteria?

Window Mart 8700 Awning holds zero Northern Zone qualifications (min U 0.28). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

How much winter heat loss does 8700 Awning conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.28 U-Factor yields 168.0 BTU/hr conductive transfer (+27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Window Mart 8700 Awning?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 8700 Awning options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Can you install Window Mart 8700 Awning in Southern or South-Central zones?

Exactly 2 8700 Awning options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.17 rather than higher 0.19 glass.

Which package tier in 8700 Awning holds Most Efficient recognition?

Zero glazing builds inside 8700 Awning's 2 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.

Can homeowners claim Form 5695 credits on Window Mart 8700 Awning in 2026?

Any 8700 Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Window Mart 8700 Awning units match permits?

Match the NFRC thermal sticker for code WMI and line WMI-K-30 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Window Mart 8700 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros