Phos Window — 1400 Picture Window · Picture Window
EPA ENERGY STAR Version 7.0 certifies 8 variants inside Phos Window 1400 Picture Window, combining Vinyl frame construction with U-Factors spanning 0.28 to 0.32 and SHGC 0.21 to 0.23. Qualifying for South-Central, Southern, this Picture Window family places #1,320 of 1,352 among 1,352 Window families and posts 0.09 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.28
- SHGC Range
- 0.21-0.23
- Certified Options
- 8
- Category Standing
- #1,320 of 1,352
How does Phos Window 1400 Picture Window compare thermally against Window peers?
Phos Window 1400 Picture Window achieves a 0.28 thermal floor across Window lines, placing #1,320 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Phos Window 1400 Picture Window standing at #1,320 of 1,352 certified Window product series, tied with 23 others at 0.28, more insulating than 0.7% of Window lines. Comparing Vinyl profiles alone (median 0.19) shows +0.09 before selecting Low-E tiers.
Mapping NFRC SHGC values (0.21 to 0.23) against ENERGY STAR Version 7.0 targets approves South-Central, Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward South-Central, Southern markets where low SHGC down to 0.21 lowers cooling load.
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 168.0 BTU/hr (+27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2026-05-12 and cert timestamp 2026-05-14.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 8 certified glazing combinations for 1400 Picture Window (NFRC ATP) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 4 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 8 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.28 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Duke Vinyl Windows — Marquis Single Hung | Vinyl | 0.28 | 0.20 | 6 |
| Duke Vinyl Windows — Marquis Double Hung | Vinyl | 0.28 | 0.19 | 12 |
| Duke Vinyl Windows — Marquis Horizontal Slider | Vinyl | 0.28 | 0.19 | 12 |
| Window Mart — 8100 Single Hung | Vinyl | 0.28 | 0.19 | 2 |
| Window Mart — 8200 Double Hung | Vinyl | 0.28 | 0.19 | 2 |
What other certified series does Phos Window produce?
Compare other active Phos Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Phos Window 1400 Picture Window appear below.
What U-Factor and SHGC range does Phos Window 1400 Picture Window achieve?
Across 8 tested NFRC glazing configurations, Phos Window 1400 Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.28 minimum U-Factor and 0.21-0.23 SHGC band. It places #1,320 among 1,352 Window series—more insulating than 0.7%.
Is 1400 Picture Window approved for Northern Zone heating climates?
No—with 0 Northern packages and a 0.28 thermal floor, Phos Window 1400 Picture Window targets warmer South-Central, Southern climates instead of cold Northern installations.
What conductive BTU/hr difference separates 1400 Picture Window from the 0.22 Northern rule?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1400 Picture Window at U 0.28 conducts 168.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying 1400 Picture Window?
Skip 1400 Picture Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 1400 Picture Window options exceeding U 0.22.
Is 1400 Picture Window suitable for sunbelt cooling-dominated homes?
Across South-Central, Southern, 8 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Phos Window 1400 Picture Window, while total line SHGC reaches 0.23 in colder packages.
How many Phos Window 1400 Picture Window variants earn ENERGY STAR Most Efficient?
ENERGY STAR Most Efficient designation is absent across all 8 1400 Picture Window options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.
What 2026 federal tax credit and Lead RRP rules apply to 1400 Picture Window?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
What permanent glass etch marks verify 1400 Picture Window after sticker removal?
Match the NFRC thermal sticker for code ATP and line ATP-M-15 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Phos Window 1400 Picture Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)