Skip to main content
Window · Vinyl Frame NFRC ATP · Product Line ATP-M-16

Phos Window — 1400 Horizontal Slider · Single Slider

With a minimum U-Factor of 0.29—+0.09 compared against the 0.20 Window median—Phos Window 1400 Horizontal Slider spans 4 tested options across Southern up to 0.29 U-Factor. Carrying NFRC CPD code ATP, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.20 and 0.22.

Min U-Factor
0.29
SHGC Range
0.20-0.22
Certified Options
4
Category Standing
#1,344 of 1,352

How does Phos Window 1400 Horizontal Slider compare thermally against Window peers?

Phos Window 1400 Horizontal Slider achieves a 0.29 thermal floor across Window lines, placing #1,344 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1400 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing 1400 Horizontal Slider (U 0.29).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.30This model: U 0.2920.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1400 Horizontal Slider Cohort StandingMin U-Factor 0.29 stands at rank #1,344 of 1,352, outperforming 2.0% of peers.Min U-Factor 0.29Rank #1,344 of 1,352 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 1400 Horizontal Slider spans 4 NFRC test records (ATP), ranking #1,344 of 1,352 Window families (tied with 3 others at 0.29, more insulating than 0.4% of Window lines). Its 0.29 thermal floor compares at +0.10 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.20 to 0.22) against ENERGY STAR Version 7.0 targets approves Southern. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward Southern markets where low SHGC down to 0.20 lowers cooling load.

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 174.0 BTU/hr (+31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2026-05-12 and cert timestamp 2026-05-14.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4 certified glazing combinations for 1400 Horizontal Slider (NFRC ATP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Not Listed <= 0.28 <= 0.23 0 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 4 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.29 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Custom Window Systems, Inc. — SH-8100 Single Hung Vinyl 0.29 0.13 157
Ram Industries Inc. — S840 Heavy Picture Window Aluminum 0.29 0.14 57
Andersen Corporation — 100 Series/Series 2 Gliding Patio Door Transom Composite 0.29 0.12 716
Duke Vinyl Windows — Marquis Single Hung Vinyl 0.28 0.20 6
Window Mart — 8100 Single Hung Vinyl 0.28 0.19 2

What other certified series does Phos Window produce?

Compare other active Phos Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Phos Window 1400 Horizontal Slider appear below.

How well does 1400 Horizontal Slider by Phos Window insulate relative to Window benchmarks?

Phos Window 1400 Horizontal Slider spans 4 certified configurations with U-Factors between 0.29 and 0.29 and SHGC values from 0.20 to 0.22. Ranked #1,344 of 1,352 Window families, it carries 0 Most Efficient options.

Can homeowners install 1400 Horizontal Slider in cold Northern ENERGY STAR counties?

Phos Window 1400 Horizontal Slider holds zero Northern Zone qualifications (min U 0.29). Homeowners in northern heating zones should skip this line and select an assembly reaching <= 0.22 U-Factor or Equivalent SHGC.

What conductive BTU/hr difference separates 1400 Horizontal Slider from the 0.22 Northern rule?

Using NFRC ATP U-Factor 0.29, a 15 sq ft Horizontal Slider (HSOX) assembly conducts 174.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (+42.0 BTU/hr margin).

When should a buyer skip Phos Window 1400 Horizontal Slider and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1400 Horizontal Slider options exceeding U 0.22. Additionally, do not order Horizontal Slider (HSOX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Phos Window 1400 Horizontal Slider in Southern or South-Central zones?

Across Southern, 4 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Phos Window 1400 Horizontal Slider, while total line SHGC reaches 0.22 in colder packages.

Does 1400 Horizontal Slider carry EPA Most Efficient certification across its lineup?

ENERGY STAR Most Efficient designation is absent across all 4 1400 Horizontal Slider options; compare peer series with lower U-Factors if your project targets Most Efficient utility tiers.

Can homeowners claim Form 5695 credits on Phos Window 1400 Horizontal Slider in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on 1400 Horizontal Slider?

Verify NFRC ID ATP and series ATP-M-16 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Phos Window 1400 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros