Skip to main content
Window · Vinyl Frame NFRC ATP · Product Line ATP-M-19

Phos Window — 1400 Single Hung · Single Hung

Positioning #1,348/1,352 in certified Window, Phos Window 1400 Single Hung pairs Vinyl frame construction with 4 glazing options rated between 0.20 and 0.22 SHGC across Southern. Across 3 certified Phos Window product families, its thermal resistance spans 0.30 to 0.30 U-Factor and the line holds standard ENERGY STAR v7.0 certification without Most Efficient packages.

Min U-Factor
0.30
SHGC Range
0.20-0.22
Certified Options
4
Category Standing
#1,348 of 1,352

How does Phos Window 1400 Single Hung compare thermally against Window peers?

Phos Window 1400 Single Hung achieves a 0.30 thermal floor across Window lines, placing #1,348 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1400 Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing 1400 Single Hung (U 0.30).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.30This model: U 0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1400 Single Hung Cohort StandingMin U-Factor 0.30 stands at rank #1,348 of 1,352, outperforming 2.0% of peers.Min U-Factor 0.30Rank #1,348 of 1,352 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 1400 Single Hung spans 4 NFRC test records (ATP), ranking #1,348 of 1,352 Window families (tied with 2 others at 0.30, more insulating than 0.1% of Window lines). Its 0.30 thermal floor compares at +0.11 against the Vinyl median (0.19).

Climate coverage for Phos Window 1400 Single Hung spans Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward Southern markets where low SHGC down to 0.20 lowers cooling load.

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.30 U-Factor yields 180.0 BTU/hr transfer (+48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2026-05-12 licensing and 2026-05-14 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 4 certified glazing combinations for 1400 Single Hung (NFRC ATP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Not Listed <= 0.28 <= 0.23 0 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 4 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.30 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Phos Window produce?

Compare other active Phos Window certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Phos Window 1400 Single Hung appear below.

How well does 1400 Single Hung by Phos Window insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 4 configurations for Phos Window 1400 Single Hung covering Southern, dropping down to U 0.30 versus a 0.20 Window median. Only 0 options earn Most Efficient status.

Can homeowners install 1400 Single Hung in cold Northern ENERGY STAR counties?

No—with 0 Northern packages and a 0.30 thermal floor, Phos Window 1400 Single Hung targets warmer Southern climates instead of cold Northern installations.

How much winter heat loss does 1400 Single Hung conduct across a 15 sq ft opening?

At U 0.30, a standard 3x5 ft (15 sq ft) 1400 Single Hung opening transfers 180.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +48.0 BTU/hr difference.

Which situations make 1400 Single Hung the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1400 Single Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Is 1400 Single Hung suitable for sunbelt cooling-dominated homes?

Yes. 4 Southern-certified options inside Phos Window 1400 Single Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.22 SHGC on west-facing glass to avoid excess afternoon solar gain.

Which package tier in 1400 Single Hung holds Most Efficient recognition?

All 4 1400 Single Hung listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

Can homeowners claim Form 5695 credits on Phos Window 1400 Single Hung in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 1400 Single Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on 1400 Single Hung?

Inspectors match the temporary NFRC sticker (U 0.30-0.30, SHGC 0.20-0.22) against permit drawings for line ATP-M-19. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Phos Window 1400 Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros