Skip to main content
Window · Vinyl Frame NFRC MEI · Product Line MEI-A-230

MI Windows and Doors, LLC — 1650I Polyvinyl Chloride (PVC) Double Hung Window · Double Hung

With a minimum U-Factor of 0.30—+0.10 compared against the 0.20 Window median—MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window spans 71 tested options across Southern up to 0.32 U-Factor. Carrying NFRC CPD code MEI, the Vinyl assembly holds standard ENERGY STAR v7.0 certification without Most Efficient packages and offers SHGC packages between 0.12 and 0.23.

Min U-Factor
0.30
SHGC Range
0.12-0.23
Certified Options
71
Category Standing
#1,348 of 1,352

How does MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window compare thermally against Window peers?

MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window achieves a 0.30 thermal floor across Window lines, placing #1,348 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1650I Polyvinyl Chloride (PVC) Double Hung WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.28-0.30 containing 1650I Polyvinyl Chloride (PVC) Double Hung Window (U 0.30).249<=0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.30This model: U 0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1650I Polyvinyl Chloride (PVC) Double Hung Window Cohort StandingMin U-Factor 0.30 stands at rank #1,348 of 1,352, outperforming 2.0% of peers.Min U-Factor 0.30Rank #1,348 of 1,352 (2.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 1650I Polyvinyl Chloride (PVC) Double Hung Window reaches 0.30 on its lowest-conductivity package — #1,007 of 1,009 in Vinyl, tied with 2 others at 0.30, lowest-ranked of 1,009 Vinyl lines (+0.11 vs Vinyl peers). Pairing NFRC ID MEI across multi-pane fills shifts U-Factor from 0.32 down toward 0.30.

Climate coverage for MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window spans Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward Southern markets where low SHGC down to 0.12 lowers cooling load.

Lifecycle documentation anchors MEI to 2024-02-29 certification (FENSTAR issued 2018-09-11). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 180.0 BTU/hr conductive loss (+36.4% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 71 certified glazing combinations for 1650I Polyvinyl Chloride (PVC) Double Hung Window (NFRC MEI) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Not Listed <= 0.22 >= 0.17 0 packages (0 Most Eff.)
North-Central Not Listed <= 0.25 <= 0.40 0 packages (0 Most Eff.)
South-Central Not Listed <= 0.28 <= 0.23 0 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 71 packages (0 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.30 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Custom Window Systems, Inc. — HS-8200 Horizontal Slider Vinyl 0.30 0.13 130
Phos Window — 1400 Single Hung Vinyl 0.30 0.20 4
Phos Window — 1400 Horizontal Slider Vinyl 0.29 0.20 4
Custom Window Systems, Inc. — SH-8100 Single Hung Vinyl 0.29 0.13 157
Ram Industries Inc. — S1100 Single Hung Aluminum 0.31 0.12 68

What other certified series does MI Windows and Doors, LLC produce?

Compare other active MI Windows and Doors, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window appear below.

What U-Factor and SHGC range does MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window achieve?

Across 71 tested NFRC glazing configurations, MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window with Vinyl framing and Double-Hung (VSDH) style reaches a 0.30 minimum U-Factor and 0.12-0.23 SHGC band. It places #1,348 among 1,352 Window series—more insulating than 0.1%.

Is 1650I Polyvinyl Chloride (PVC) Double Hung Window approved for Northern Zone heating climates?

This series is excluded from Northern ENERGY STAR eligibility (0 qualified options; floor U 0.30). Focus on Southern glazing applications where SHGC 0.12-0.23 manages cooling loads.

How much winter heat loss does 1650I Polyvinyl Chloride (PVC) Double Hung Window conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 180.0 BTU/hr on 1650I Polyvinyl Chloride (PVC) Double Hung Window's lowest-U package (0.30), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.

What are the practical limitations of specifying 1650I Polyvinyl Chloride (PVC) Double Hung Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1650I Polyvinyl Chloride (PVC) Double Hung Window options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in 1650I Polyvinyl Chloride (PVC) Double Hung Window?

Warm-climate homeowners have 71 Southern-approved options within 1650I Polyvinyl Chloride (PVC) Double Hung Window spanning SHGC down to 0.12. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

How many MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window variants earn ENERGY STAR Most Efficient?

All 71 1650I Polyvinyl Chloride (PVC) Double Hung Window listings belong to the standard ENERGY STAR v7.0 tier (0 Most Efficient options), focusing on baseline compliance rather than ultra-low-U triple glazing.

What federal compliance checks govern 2026 1650I Polyvinyl Chloride (PVC) Double Hung Window window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 1650I Polyvinyl Chloride (PVC) Double Hung Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify 1650I Polyvinyl Chloride (PVC) Double Hung Window after sticker removal?

Match the NFRC thermal sticker for code MEI and line MEI-A-230 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for MI Windows and Doors, LLC 1650I Polyvinyl Chloride (PVC) Double Hung Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros