Value Windows & Doors — AL-CM · Casement Windows
Value Windows & Doors engineered the AL-CM Casement Windows line for Southern, certifying 17 glass-spacer combinations from 0.31 to 0.32 U-Factor and 0.13 to 0.17 SHGC. Relative to other Aluminum models tracked under NFRC VWS, its minimum U-Factor is 0.08 Btu/hr·ft²·°F less insulating than the 0.23 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.31
- SHGC Range
- 0.13-0.17
- Certified Options
- 17
- Category Standing
- #1,351 of 1,352
How does Value Windows & Doors AL-CM compare thermally against Window peers?
Value Windows & Doors AL-CM achieves a 0.31 thermal floor across Window lines, placing #1,351 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Value Windows & Doors AL-CM standing at #1,351 of 1,352 certified Window product series, tied with 1 other at 0.31, lowest-ranked of 1,352 Window lines. Comparing Aluminum profiles alone (median 0.23) shows +0.08 before selecting Low-E tiers.
Evaluating climate compliance across Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. Not qualified for Northern Zone prescriptive or equivalent thresholds; specifications steer toward Southern markets where low SHGC down to 0.13 lowers cooling load.
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.31 U-Factor yields 186.0 BTU/hr transfer (+54.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2019-01-31 licensing and 2024-05-14 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 17 certified glazing combinations for AL-CM (NFRC VWS) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Not Listed | <= 0.22 | >= 0.17 | 0 packages (0 Most Eff.) |
| North-Central | Not Listed | <= 0.25 | <= 0.40 | 0 packages (0 Most Eff.) |
| South-Central | Not Listed | <= 0.28 | <= 0.23 | 0 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 17 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.31 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Ram Industries Inc. — S1100 Single Hung | Aluminum | 0.31 | 0.12 | 68 |
| Phos Window — 1400 Single Hung | Vinyl | 0.30 | 0.20 | 4 |
| MI Windows and Doors, LLC — 1650I Polyvinyl Chloride (PVC) Double Hung Window | Vinyl | 0.30 | 0.12 | 71 |
| Custom Window Systems, Inc. — HS-8200 Horizontal Slider | Vinyl | 0.30 | 0.13 | 130 |
| Ram Industries Inc. — S840 Heavy Picture Window | Aluminum | 0.29 | 0.14 | 57 |
What other certified series does Value Windows & Doors produce?
Compare other active Value Windows & Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
EuroTek Tilt and Turn Window
U-Factor 0.17–0.27 · 219 certified options.
IM/GX/GS Sliding Patio Door
U-Factor 0.18–0.28 · 1,869 certified options.
EuroTek Outswing Door
U-Factor 0.19–0.27 · 64 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Value Windows & Doors AL-CM appear below.
What thermal performance numbers separate Value Windows & Doors AL-CM from peers?
Across 17 tested NFRC glazing configurations, Value Windows & Doors AL-CM with Aluminum framing and Casement Single-Vent (CSSV) style reaches a 0.31 minimum U-Factor and 0.13-0.17 SHGC band. It places #1,351 among 1,352 Window series—bottom tier.
How does Value Windows & Doors AL-CM satisfy Version 7.0 Northern criteria?
Northern Zone certification is absent for AL-CM (0 qualifying options, min U 0.31). Install this Casement Single-Vent (CSSV) product only within Southern regions where lower SHGC caps apply.
What BTU/hr heat transfer results from AL-CM's 0.31 minimum U-Factor?
At U 0.31, a standard 3x5 ft (15 sq ft) AL-CM opening transfers 186.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a +54.0 BTU/hr difference.
Which situations make AL-CM the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on AL-CM options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
What Southern ENERGY STAR v7.0 options exist in AL-CM?
Yes. 17 Southern-certified options inside Value Windows & Doors AL-CM satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.17 SHGC on west-facing glass to avoid excess afternoon solar gain.
Does AL-CM carry EPA Most Efficient certification across its lineup?
Zero glazing builds inside AL-CM's 17 certified options achieve Most Efficient status. Buyers seeking Most Efficient performance should inspect the nearest peer lines in the comparison table above.
Can homeowners claim Form 5695 credits on Value Windows & Doors AL-CM in 2026?
Any AL-CM purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify AL-CM after sticker removal?
Confirm both the paper NFRC label and permanent corner glass etch match line VWS-A-44 and NFRC ID VWS before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Value Windows & Doors AL-CM come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)