QUANTAPANEL — 502-PW Architectural Low-e Storm Window N ENERGY STAR Storm Window Specs
QUANTAPANEL 502-PW Architectural Low-e Storm Window N (502-PW Architectural Low-e Storm Window N) is an EPA ENERGY STAR certified Aluminum Exterior Storm Window (Fixed/Stationary/Picture, Single-Track/fixed) tested at 0.16 Low-E emissivity (0.01 lower emissivity than the 0.17 median), 0.74 solar transmittance, and 1.10 cfm/ft2 AERC 1.2 air leakage for Northern retrofits. Closest Cohort Match: Compared to Chosen Fixed Slip Low-e (emissivity 0.16, air 1.50 cfm/ft2), 502-PW Architectural Low-e Storm Window N runs +0.00 on emissivity and -0.40 cfm/ft2 on air sealing, with +0.00 solar transmittance spread. Paired over intact single-pane sashes near ~$188 per opening, homeowners capture roughly $350/yr energy savings.
- Low-E Emissivity
- 0.16 (<= 0.22)
- Solar Transmittance
- 0.74
- AERC Air Leakage
- 1.10 cfm/ft2
- Target Zone
- Northern
What optical and air-leakage specifications define QUANTAPANEL 502-PW Architectural Low-e Storm Window N?
Official EPA ENERGY STAR dataset qaxz-ikcb optical and air-infiltration test figures for QUANTAPANEL 502-PW Architectural Low-e Storm Window N (Northern) appear in the specification matrix below.
| Storm Window Metric | Certified Value | EPA Benchmark / Engineering Context |
|---|---|---|
| Brand & Partner | QUANTAPANEL | Partner: QUANTA Technologies, Inc. |
| Model Number / Type | 502-PW Architectural Low-e Storm Window N | Exterior Storm Window |
| Emissivity Rating | 0.16 | EPA Low-E threshold <= 0.22 |
| Solar Transmittance | 0.74 | Zone-matched solar gain control |
| AERC 1.2 Air Leakage | 1.10 cfm/ft2 | Reduces single-pane sash drafts |
| Tracks & Glazing | Single-Track/fixed · 1 | Aluminum · Limited, 20 year |
Surface coating performance at 0.16 emissivity (0.01 lower emissivity than the 0.17 median) cuts winter radiative loss across Northern single-pane assemblies without darkening interior rooms.
Transmitting 0.74 of incident solar energy makes QUANTAPANEL 502-PW Architectural Low-e Storm Window N best suited to heating-dominated northern facades needing free winter solar warmth.
Because 502-PW Architectural Low-e Storm Window N tests at 1.10 cfm/ft2 (matching the cohort median), pair installation with compressible bronze or foam sash weatherstripping on the existing prime frame.
Closest Cohort Match: Compared to Chosen Fixed Slip Low-e (emissivity 0.16, air 1.50 cfm/ft2), 502-PW Architectural Low-e Storm Window N runs +0.00 on emissivity and -0.40 cfm/ft2 on air sealing, with +0.00 solar transmittance spread.
Budget Payback Profile: EPA storm window field studies estimate ~10% annual HVAC savings (~$350/yr) when 0.16 Low-E units like 502-PW Architectural Low-e Storm Window N cover leaky single-pane glass.
Installation & Warranty Context: Configured as Exterior Storm Window (Single-Track/fixed Aluminum), 502-PW Architectural Low-e Storm Window N carries Limited, 20 year OEM coverage and requires unobstructed lower sill weep ports.
Which certified ENERGY STAR storm windows sit closest on emissivity and air sealing?
Evaluate nearby Low-E storm window models across alternative certified lines sorted by emissivity proximity to QUANTAPANEL 502-PW Architectural Low-e Storm Window N (0.16).
| Peer Storm Window | Zone Target | Emissivity | Solar Trans. | Air Leakage |
|---|---|---|---|---|
| Chosen — Fixed Slip Low-e | Northern | 0.16 | 0.74 | 1.50 |
| QUANTAPANEL — 504-DH Architectural Low-e Storm Window N | Northern | 0.16 | 0.74 | 1.30 |
| QUANTAPANEL — 506-SL Architectural Low-e Storm Window N | Northern | 0.16 | 0.74 | 1.10 |
| QUANTAPANEL — 602-PW Architectural Low-e Storm Window | Northern | 0.16 | 0.74 | 0.10 |
| QUANTAPANEL — 604-DH Architectural Low-e Storm Window | Northern | 0.16 | 0.74 | 0.40 |
Who should NOT install storm windows instead of full-frame units?
Review structural sill soundness, historic trim preservation, weep-slot drainage, and moisture constraints before ordering QUANTAPANEL 502-PW Architectural Low-e Storm Window N storm panels.
Structural jamb decay disqualifies 502-PW Architectural Low-e Storm Window N storm kits
If Northern single-pane sills already show fungal softness or broken sash balances, full-frame window replacement outperforms overlaying 502-PW Architectural Low-e Storm Window N (502-PW Architectural Low-e Storm Window N).
Prevent trapped sash condensation behind QUANTAPANEL 502-PW Architectural Low-e Storm Window N
Inspect exterior perimeter caulking around 502-PW Architectural Low-e Storm Window N (Northern) and leave bottom weep slots open along the outer sill nose so pressure-equalized moisture escapes freely.
What historic preservation, payback, and installation questions apply?
Explore frequently asked questions covering QUANTAPANEL 502-PW Architectural Low-e Storm Window N emissivity payback, Single-Track/fixed operation, IRC R310 egress rules, and tear-out trade-offs.
Are ENERGY STAR storm tracks like 502-PW Architectural Low-e Storm Window N cost-effective over single-pane glass?
Adding QUANTAPANEL 502-PW Architectural Low-e Storm Window N (0.16 Low-E coating, 1.10 cfm/ft2 air leakage) at ~$188 per opening cuts single-pane conduction and draft losses by roughly 10% annually (~$350/yr), yielding an ~3-year payback.
How is QUANTAPANEL 502-PW Architectural Low-e Storm Window N constructed for Northern exposure?
QUANTAPANEL manufactures 502-PW Architectural Low-e Storm Window N with Aluminum framing in an Fixed/Stationary/Picture layout (Single-Track/fixed) glazed with 1 and backed by Limited, 20 year coverage.
Does installing QUANTAPANEL 502-PW Architectural Low-e Storm Window N shrink IRC R310 bedroom egress clearances?
Exterior storm tracks like QUANTAPANEL 502-PW Architectural Low-e Storm Window N mount outboard of existing wood stops, though operable sashes must slide cleanly open to preserve IRC Section R310 5.7 sq ft bedroom escape clearances.
When does a window opening fail storm window retrofit eligibility for 502-PW Architectural Low-e Storm Window N?
Homeowners with decayed wood sills, broken sash cords, or fogged double-pane IGU seals should choose full replacement over QUANTAPANEL 502-PW Architectural Low-e Storm Window N, as storm panels only preserve structurally sound frames.
Which official federal and state sources back this page?
Optical emissivity, solar transmittance, and air-sealing records for QUANTAPANEL 502-PW Architectural Low-e Storm Window N cite EPA ENERGY STAR qaxz-ikcb and federal REMDB cost files.
- ENERGY STAR Certified Storm Windows Dataset (qaxz-ikcb) — U.S. EPA ENERGY STAR, 2026-11 (checked 2026-11-23)
- ENERGY STAR Windows, Doors, Skylights & Storm Windows Homeowner Savings Methodology — U.S. EPA / U.S. DOE ENERGY STAR, v7.0 (checked 2026-11-24)
- National Residential Efficiency Measures Database (REMDB) — Component Unit Cost Formulas — National Renewable Energy Laboratory (U.S. DOE), 2023 Cost Database (checked 2026-11-24)
- International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering) — International Code Council (ICC), 2021/2024 IRC (cite only) (checked 2026-11-23)