ENERGY STAR Storm Window · Northern Aluminum Frame · Vertical Slider/Single-Double Hung

QUANTAPANEL — 506-SL Architectural Low-e Storm Window N ENERGY STAR Storm Window Specs

Engineered for Northern single-pane preservation, QUANTAPANEL 506-SL Architectural Low-e Storm Window N delivers 0.16 surface emissivity (under EPA's 0.22 ceiling), 0.74 solar heat transmittance, and 1.10 cfm/ft2 AERC air tightness in an Vertical Slider/Single-Double Hung Aluminum sash track. Upgrading sound timber frames avoids $1,000+ tear-out bids while recovering ~$188 unit costs via ~$350/yr HVAC bill reductions.

See $350/yr Storm Window Savings
Low-E Emissivity
0.16 (<= 0.22)
Solar Transmittance
0.74
AERC Air Leakage
1.10 cfm/ft2
Target Zone
Northern

What optical and air-leakage specifications define QUANTAPANEL 506-SL Architectural Low-e Storm Window N?

Examine QUANTAPANEL 506-SL Architectural Low-e Storm Window N's certified thermal coating metrics, glazing layers, and AERC air-sealing figures alongside climate suitability notes below.

Storm Window Metric Certified Value EPA Benchmark / Engineering Context
Brand & PartnerQUANTAPANELPartner: QUANTA Technologies, Inc.
Model Number / Type506-SL Architectural Low-e Storm Window NExterior Storm Window
Emissivity Rating0.16EPA Low-E threshold <= 0.22
Solar Transmittance0.74Zone-matched solar gain control
AERC 1.2 Air Leakage1.10 cfm/ft2Reduces single-pane sash drafts
Tracks & GlazingTwo-Track · 1Aluminum · 20 years

Mid-band 0.16 Low-E emissivity satisfies EPA's <= 0.22 threshold (0.01 lower emissivity than the 0.17 median), balancing radiant warmth retention and visible daylight clarity.

A 0.74 solar transmittance figure preserves bright daylighting and passive winter heat gain over Aluminum storm tracks in Northern installations.

Recording 1.10 cfm/ft2 air infiltration (matching the cohort median), QUANTAPANEL 506-SL Architectural Low-e Storm Window N relies primarily on its 0.16 Low-E glass rather than ultra-tight compression gaskets.

Closest Cohort Match: Compared to Chosen Fixed Slip Low-e (emissivity 0.16, air 1.50 cfm/ft2), 506-SL Architectural Low-e Storm Window N runs +0.00 on emissivity and -0.40 cfm/ft2 on air sealing, with +0.00 solar transmittance spread.

Preservation Economics for 506-SL Architectural Low-e Storm Window N: At ~$188 typical installed cost per 15 sq ft opening vs. $1,000+ tear-out bids, EPA's ~$350/yr estimated savings targets a ~3-year payback.

Installation & Warranty Context: Configured as Exterior Storm Window (Two-Track Aluminum), 506-SL Architectural Low-e Storm Window N carries 20 years OEM coverage and requires unobstructed lower sill weep ports.

Which certified ENERGY STAR storm windows sit closest on emissivity and air sealing?

Side-by-side peer specifications benchmark 506-SL Architectural Low-e Storm Window N against five competing certified storm frames on emissivity, solar transmittance, and air leakage.

Peer Storm Window Zone Target Emissivity Solar Trans. Air Leakage
Chosen — Fixed Slip Low-e Northern 0.16 0.74 1.50
QUANTAPANEL — 502-PW Architectural Low-e Storm Window N Northern 0.16 0.74 1.10
QUANTAPANEL — 504-DH Architectural Low-e Storm Window N Northern 0.16 0.74 1.30
QUANTAPANEL — 602-PW Architectural Low-e Storm Window Northern 0.16 0.74 0.10
QUANTAPANEL — 604-DH Architectural Low-e Storm Window Northern 0.16 0.74 0.40

Who should NOT install storm windows instead of full-frame units?

Check primary wood frame conditions, interior sash weatherstripping, and sill weep-hole drainage guidelines before installing 506-SL Architectural Low-e Storm Window N (Aluminum) overlays.

Rotted primary wood sills before mounting QUANTAPANEL 506-SL Architectural Low-e Storm Window N

Storm panels like 506-SL Architectural Low-e Storm Window N require sound exterior blind stops for perimeter fastening—decayed sills allow rainwater intrusion behind the Aluminum track.

Interior vapor buildup risks with 506-SL Architectural Low-e Storm Window N overlays

Verify sleeping-room sashes under 506-SL Architectural Low-e Storm Window N slide smoothly without locking screws so IRC Section R310 5.7 sq ft emergency escape clearances remain functional.

What historic preservation, payback, and installation questions apply?

Answers below clarify single-pane energy savings, warranty filings, sleeping-room egress safety, and disqualifying frame rot for QUANTAPANEL 506-SL Architectural Low-e Storm Window N.

What utility payback does QUANTAPANEL 506-SL Architectural Low-e Storm Window N deliver on older wood sashes?

EPA ENERGY STAR storm window data estimates roughly $350/yr HVAC savings across a typical U.S. home when installing a <= 0.22 emissivity overlay such as QUANTAPANEL 506-SL Architectural Low-e Storm Window N (0.16 emissivity) over intact single-pane frames.

What frame, track style, and warranty does 506-SL Architectural Low-e Storm Window N carry?

QUANTAPANEL manufactures 506-SL Architectural Low-e Storm Window N with Aluminum framing in an Vertical Slider/Single-Double Hung layout (Two-Track) glazed with 1 and backed by 20 years coverage.

Does installing QUANTAPANEL 506-SL Architectural Low-e Storm Window N shrink IRC R310 bedroom egress clearances?

Because 506-SL Architectural Low-e Storm Window N attaches to exterior blind stops rather than shrinking interior jamb liners, bedroom egress width stays intact provided the Vertical Slider/Single-Double Hung insert opens freely without latching screws.

When does a window opening fail storm window retrofit eligibility for 506-SL Architectural Low-e Storm Window N?

Do not overlay 506-SL Architectural Low-e Storm Window N (Aluminum) onto rotted perimeter frames, warped sashes that leak rainwater, or existing dual-pane units whose inner glass seals have already failed.

Which official federal and state sources back this page?

Every tested metric for QUANTAPANEL 506-SL Architectural Low-e Storm Window N resolves directly to official EPA ENERGY STAR Storm Windows certification filings and IRC R310 guidelines.

  1. ENERGY STAR Certified Storm Windows Dataset (qaxz-ikcb) — U.S. EPA ENERGY STAR, 2026-11 (checked 2026-11-23)
  2. ENERGY STAR Windows, Doors, Skylights & Storm Windows Homeowner Savings Methodology — U.S. EPA / U.S. DOE ENERGY STAR, v7.0 (checked 2026-11-24)
  3. National Residential Efficiency Measures Database (REMDB) — Component Unit Cost Formulas — National Renewable Energy Laboratory (U.S. DOE), 2023 Cost Database (checked 2026-11-24)
  4. International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering) — International Code Council (ICC), 2021/2024 IRC (cite only) (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros