QUANTAPANEL — 502-PW Architectural T Low-e Storm Window ENERGY STAR Storm Window Specs
QUANTAPANEL 502-PW Architectural T Low-e Storm Window (502-PW Architectural T Low-e Storm Window) is an EPA ENERGY STAR certified Aluminum Exterior Storm Window (Fixed/Stationary/Picture, Single-Track/fixed) tested at 0.20 Low-E emissivity (0.03 above the 0.17 median), 0.77 solar transmittance, and 1.10 cfm/ft2 AERC 1.2 air leakage for Northern retrofits. Closest Cohort Match: Compared to QUANTAPANEL 504-DH Architectural T Low-e Storm Window (emissivity 0.20, air 1.30 cfm/ft2), 502-PW Architectural T Low-e Storm Window runs +0.00 on emissivity and -0.20 cfm/ft2 on air sealing, with +0.00 solar transmittance spread. Paired over intact single-pane sashes near ~$188 per opening, homeowners capture roughly $350/yr energy savings.
- Low-E Emissivity
- 0.20 (<= 0.22)
- Solar Transmittance
- 0.77
- AERC Air Leakage
- 1.10 cfm/ft2
- Target Zone
- Northern
What optical and air-leakage specifications define QUANTAPANEL 502-PW Architectural T Low-e Storm Window?
Review verified emissivity, solar transmittance, track configuration, and AERC 1.2 leakage benchmarks recorded for QUANTAPANEL 502-PW Architectural T Low-e Storm Window (502-PW Architectural T Low-e Storm Window) in the table below.
| Storm Window Metric | Certified Value | EPA Benchmark / Engineering Context |
|---|---|---|
| Brand & Partner | QUANTAPANEL | Partner: QUANTA Technologies, Inc. |
| Model Number / Type | 502-PW Architectural T Low-e Storm Window | Exterior Storm Window |
| Emissivity Rating | 0.20 | EPA Low-E threshold <= 0.22 |
| Solar Transmittance | 0.77 | Zone-matched solar gain control |
| AERC 1.2 Air Leakage | 1.10 cfm/ft2 | Reduces single-pane sash drafts |
| Tracks & Glazing | Single-Track/fixed · 1 | Aluminum · Limited, 20 year |
Certified at 0.20 emissivity (<= 0.22 EPA cap; 0.03 above the 0.17 median), 502-PW Architectural T Low-e Storm Window suits homeowners prioritizing daytime brightness over ultra-dark Low-E coatings.
A 0.77 solar transmittance figure preserves bright daylighting and passive winter heat gain over Aluminum storm tracks in Northern installations.
Because 502-PW Architectural T Low-e Storm Window tests at 1.10 cfm/ft2 (matching the cohort median), pair installation with compressible bronze or foam sash weatherstripping on the existing prime frame.
Closest Cohort Match: Compared to QUANTAPANEL 504-DH Architectural T Low-e Storm Window (emissivity 0.20, air 1.30 cfm/ft2), 502-PW Architectural T Low-e Storm Window runs +0.00 on emissivity and -0.20 cfm/ft2 on air sealing, with +0.00 solar transmittance spread.
ROI vs. Full Replacement: Keeping sound wood frames under 502-PW Architectural T Low-e Storm Window (Single-Track/fixed Aluminum) sidesteps $1,000+ unit replacements while capturing ~$350/yr heating and cooling savings.
Climate & Operation Match: Northern targeting with Fixed/Stationary/Picture hardware (Single-Track/fixed track) suits stationary picture openings under Limited, 20 year OEM coverage.
Which certified ENERGY STAR storm windows sit closest on emissivity and air sealing?
Compare five neighboring EPA ENERGY STAR storm windows ranked closest to QUANTAPANEL 502-PW Architectural T Low-e Storm Window's 0.20 surface emissivity and AERC air sealing.
| Peer Storm Window | Zone Target | Emissivity | Solar Trans. | Air Leakage |
|---|---|---|---|---|
| QUANTAPANEL — 504-DH Architectural T Low-e Storm Window | Northern | 0.20 | 0.77 | 1.30 |
| QUANTAPANEL — 506-SL Architectural T Low-e Storm Window N | Northern | 0.20 | 0.77 | 1.10 |
| QUANTAPANEL — 602-PW Architectural T Low-e Storm Windows | Northern | 0.20 | 0.77 | 0.10 |
| QUANTAPANEL — 604 DH Architectural T Low-e Storm Window | Northern | 0.20 | 0.77 | 0.40 |
| QUANTAPANEL — 605-DH Architectural T Low-e Storm Window | Northern | 0.20 | 0.77 | 0.40 |
Who should NOT install storm windows instead of full-frame units?
Review structural sill soundness, historic trim preservation, weep-slot drainage, and moisture constraints before ordering QUANTAPANEL 502-PW Architectural T Low-e Storm Window storm panels.
Rotted primary wood sills before mounting QUANTAPANEL 502-PW Architectural T Low-e Storm Window
Mounting QUANTAPANEL 502-PW Architectural T Low-e Storm Window (Aluminum) over softened exterior sills traps wind-driven moisture against decayed wood; restore structural jambs with epoxy patches first or pick full-frame replacement.
Interior vapor buildup risks with 502-PW Architectural T Low-e Storm Window overlays
Keep bottom sill weep ports clear on QUANTAPANEL 502-PW Architectural T Low-e Storm Window so exterior rainwater and winter sash condensation drain outward across the wood sill rather than pooling indoors.
What historic preservation, payback, and installation questions apply?
Review practical homeowner answers explaining 502-PW Architectural T Low-e Storm Window utility payback, bedroom escape clearance compliance, and frame eligibility before ordering storm tracks.
What utility payback does QUANTAPANEL 502-PW Architectural T Low-e Storm Window deliver on older wood sashes?
Adding QUANTAPANEL 502-PW Architectural T Low-e Storm Window (0.20 Low-E coating, 1.10 cfm/ft2 air leakage) at ~$188 per opening cuts single-pane conduction and draft losses by roughly 10% annually (~$350/yr), yielding an ~3-year payback.
How is QUANTAPANEL 502-PW Architectural T Low-e Storm Window constructed for Northern exposure?
QUANTAPANEL manufactures 502-PW Architectural T Low-e Storm Window with Aluminum framing in an Fixed/Stationary/Picture layout (Single-Track/fixed) glazed with 1 and backed by Limited, 20 year coverage.
Can 502-PW Architectural T Low-e Storm Window be mounted on sleeping room windows under IRC code?
Exterior storm tracks like QUANTAPANEL 502-PW Architectural T Low-e Storm Window mount outboard of existing wood stops, though operable sashes must slide cleanly open to preserve IRC Section R310 5.7 sq ft bedroom escape clearances.
When does a window opening fail storm window retrofit eligibility for 502-PW Architectural T Low-e Storm Window?
Homeowners with decayed wood sills, broken sash cords, or fogged double-pane IGU seals should choose full replacement over QUANTAPANEL 502-PW Architectural T Low-e Storm Window, as storm panels only preserve structurally sound frames.
Which official federal and state sources back this page?
Optical emissivity, solar transmittance, and air-sealing records for QUANTAPANEL 502-PW Architectural T Low-e Storm Window cite EPA ENERGY STAR qaxz-ikcb and federal REMDB cost files.
- ENERGY STAR Certified Storm Windows Dataset (qaxz-ikcb) — U.S. EPA ENERGY STAR, 2026-11 (checked 2026-11-23)
- ENERGY STAR Windows, Doors, Skylights & Storm Windows Homeowner Savings Methodology — U.S. EPA / U.S. DOE ENERGY STAR, v7.0 (checked 2026-11-24)
- National Residential Efficiency Measures Database (REMDB) — Component Unit Cost Formulas — National Renewable Energy Laboratory (U.S. DOE), 2023 Cost Database (checked 2026-11-24)
- International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering) — International Code Council (ICC), 2021/2024 IRC (cite only) (checked 2026-11-23)