Skip to main content
ENERGY STAR Storm Window · Northern Aluminum Frame · Vertical Slider/Single-Double Hung

QUANTAPANEL — 604 DH Architectural T Low-e Storm Window ENERGY STAR Storm Window Specs

Certified under EPA ENERGY STAR Storm Windows as 604 DH Architectural T Low-e Storm Window, QUANTAPANEL 604 DH Architectural T Low-e Storm Window achieves 0.20 emissivity (0.03 above the 0.17 median), 0.77 solar transmittance, and 0.40 cfm/ft2 AERC 1.2 air leakage across Two-Track Aluminum profiles (Limited, 20 years OEM coverage). Against the 30-model EPA cohort, it tracks closely with QUANTAPANEL 502-PW Architectural T Low-e Storm Window while saving ~$350/yr on single-pane utility bills.

See $350/yr Storm Window Savings
Low-E Emissivity
0.20 (<= 0.22)
Solar Transmittance
0.77
AERC Air Leakage
0.40 cfm/ft2
Target Zone
Northern

What optical and air-leakage specifications define QUANTAPANEL 604 DH Architectural T Low-e Storm Window?

Federal EPA ENERGY STAR qaxz-ikcb engineering data below summarizes radiant emissivity, solar gain transmission, and draft resistance for QUANTAPANEL 604 DH Architectural T Low-e Storm Window.

Storm Window Metric Certified Value EPA Benchmark / Engineering Context
Brand & PartnerQUANTAPANELPartner: QUANTA Technologies, Inc.
Model Number / Type604 DH Architectural T Low-e Storm WindowInterior Storm Window
Emissivity Rating0.20EPA Low-E threshold <= 0.22
Solar Transmittance0.77Zone-matched solar gain control
AERC 1.2 Air Leakage0.40 cfm/ft2Reduces single-pane sash drafts
Tracks & GlazingTwo-Track · 1Aluminum · Limited, 20 years

Certified at 0.20 emissivity (<= 0.22 EPA cap; 0.03 above the 0.17 median), 604 DH Architectural T Low-e Storm Window suits homeowners prioritizing daytime brightness over ultra-dark Low-E coatings.

A 0.77 solar transmittance figure preserves bright daylighting and passive winter heat gain over Aluminum storm tracks in Northern installations.

Moderate 0.40 cfm/ft2 AERC 1.2 air infiltration (0.70 cfm/ft2 tighter than the 1.10 median) curbs noticeable sash rattles across Vertical Slider/Single-Double Hung Two-Track Aluminum tracks.

Alternative Comparison: Shoppers weighing 604 DH Architectural T Low-e Storm Window (0.20 emissivity, 0.40 cfm/ft2) against QUANTAPANEL 502-PW Architectural T Low-e Storm Window (0.20 / 1.10) and QUANTAPANEL 504-DH Architectural T Low-e Storm Window (0.20 / 1.30) see 0.00 solar transmittance variance.

Preservation Economics for 604 DH Architectural T Low-e Storm Window: At ~$188 typical installed cost per 15 sq ft opening vs. $1,000+ tear-out bids, EPA's ~$350/yr estimated savings targets a ~3-year payback.

Installation & Warranty Context: Configured as Interior Storm Window (Two-Track Aluminum), 604 DH Architectural T Low-e Storm Window carries Limited, 20 years OEM coverage and requires unobstructed lower sill weep ports.

Which certified ENERGY STAR storm windows sit closest on emissivity and air sealing?

Inspect the five closest ENERGY STAR storm window alternatives matched to QUANTAPANEL 604 DH Architectural T Low-e Storm Window across emissivity, solar transmission, and air tightness.

Peer Storm Window Zone Target Emissivity Solar Trans. Air Leakage
QUANTAPANEL — 502-PW Architectural T Low-e Storm Window Northern 0.20 0.77 1.10
QUANTAPANEL — 504-DH Architectural T Low-e Storm Window Northern 0.20 0.77 1.30
QUANTAPANEL — 506-SL Architectural T Low-e Storm Window N Northern 0.20 0.77 1.10
QUANTAPANEL — 602-PW Architectural T Low-e Storm Windows Northern 0.20 0.77 0.10
QUANTAPANEL — 605-DH Architectural T Low-e Storm Window Northern 0.20 0.77 0.40

Who should NOT install storm windows instead of full-frame units?

Verify blind-stop framing integrity and unblocked bottom sill drainage slots before mounting 604 DH Architectural T Low-e Storm Window (Vertical Slider/Single-Double Hung) over historic single-pane windows.

Structural jamb decay disqualifies 604 DH Architectural T Low-e Storm Window storm kits

Before hanging 604 DH Architectural T Low-e Storm Window (Vertical Slider/Single-Double Hung), probe lower sills and blind stops for rot—covering damaged sashes hides ongoing decay instead of sealing an intact single-pane frame.

Drainage weep slots & coastal exposure for 604 DH Architectural T Low-e Storm Window

Maintain unobstructed sill drainage paths beneath QUANTAPANEL 604 DH Architectural T Low-e Storm Window (Aluminum) and clear dust from lower track channels each autumn.

What historic preservation, payback, and installation questions apply?

Review practical homeowner answers explaining 604 DH Architectural T Low-e Storm Window utility payback, bedroom escape clearance compliance, and frame eligibility before ordering storm tracks.

Are ENERGY STAR storm tracks like 604 DH Architectural T Low-e Storm Window cost-effective over single-pane glass?

Adding QUANTAPANEL 604 DH Architectural T Low-e Storm Window (0.20 Low-E coating, 0.40 cfm/ft2 air leakage) at ~$188 per opening cuts single-pane conduction and draft losses by roughly 10% annually (~$350/yr), yielding an ~3-year payback.

How is QUANTAPANEL 604 DH Architectural T Low-e Storm Window constructed for Northern exposure?

QUANTAPANEL manufactures 604 DH Architectural T Low-e Storm Window with Aluminum framing in an Vertical Slider/Single-Double Hung layout (Two-Track) glazed with 1 and backed by Limited, 20 years coverage.

Does installing QUANTAPANEL 604 DH Architectural T Low-e Storm Window shrink IRC R310 bedroom egress clearances?

Because 604 DH Architectural T Low-e Storm Window attaches to exterior blind stops rather than shrinking interior jamb liners, bedroom egress width stays intact provided the Vertical Slider/Single-Double Hung insert opens freely without latching screws.

Who should NOT buy QUANTAPANEL 604 DH Architectural T Low-e Storm Window instead of full replacement?

Homeowners with decayed wood sills, broken sash cords, or fogged double-pane IGU seals should choose full replacement over QUANTAPANEL 604 DH Architectural T Low-e Storm Window, as storm panels only preserve structurally sound frames.

Which official federal and state sources back this page?

Verify QUANTAPANEL 604 DH Architectural T Low-e Storm Window certification attributes, AERC air-leakage rules, and residential rebate status against the primary government sources below.

  1. ENERGY STAR Certified Storm Windows Dataset (qaxz-ikcb) — U.S. EPA ENERGY STAR, 2026-11 (checked 2026-11-23)
  2. ENERGY STAR Windows, Doors, Skylights & Storm Windows Homeowner Savings Methodology — U.S. EPA / U.S. DOE ENERGY STAR, v7.0 (checked 2026-11-24)
  3. National Residential Efficiency Measures Database (REMDB) — Component Unit Cost Formulas — National Renewable Energy Laboratory (U.S. DOE), 2023 Cost Database (checked 2026-11-24)
  4. International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering) — International Code Council (ICC), 2021/2024 IRC (cite only) (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros