QUANTAPANEL — 506-SL Architectural Low-e Storm Window S ENERGY STAR Storm Window Specs
Registered for Southern exterior or interior retrofits, QUANTAPANEL 506-SL Architectural Low-e Storm Window S (506-SL Architectural Low-e Storm Window S) uses 1 glazing inside Two-Track Aluminum frames to achieve 0.17 Low-E emissivity and 1.30 cfm/ft2 air tightness (0.20 cfm/ft2 above the 1.10 median). Its 0.46 solar transmittance compares cleanly with QUANTAPANEL 502-PW Architectural Low-e Storm Window S (0.46 solar), offering ~3-year payback over ~$188 installed costs.
- Low-E Emissivity
- 0.17 (<= 0.22)
- Solar Transmittance
- 0.46
- AERC Air Leakage
- 1.30 cfm/ft2
- Target Zone
- Southern
What optical and air-leakage specifications define QUANTAPANEL 506-SL Architectural Low-e Storm Window S?
Federal EPA ENERGY STAR qaxz-ikcb engineering data below summarizes radiant emissivity, solar gain transmission, and draft resistance for QUANTAPANEL 506-SL Architectural Low-e Storm Window S.
| Storm Window Metric | Certified Value | EPA Benchmark / Engineering Context |
|---|---|---|
| Brand & Partner | QUANTAPANEL | Partner: QUANTA Technologies, Inc. |
| Model Number / Type | 506-SL Architectural Low-e Storm Window S | Exterior Storm Window |
| Emissivity Rating | 0.17 | EPA Low-E threshold <= 0.22 |
| Solar Transmittance | 0.46 | Zone-matched solar gain control |
| AERC 1.2 Air Leakage | 1.30 cfm/ft2 | Reduces single-pane sash drafts |
| Tracks & Glazing | Two-Track · 1 | Aluminum · Limited, 20 years |
Surface coating performance at 0.17 emissivity (matching the cohort median) cuts winter radiative loss across Southern single-pane assemblies without darkening interior rooms.
Balanced 0.46 solar transmittance moderates summer afternoon glare while still capturing useful winter solar gain across Southern homes.
Because 506-SL Architectural Low-e Storm Window S tests at 1.30 cfm/ft2 (0.20 cfm/ft2 above the 1.10 median), pair installation with compressible bronze or foam sash weatherstripping on the existing prime frame.
Head-to-Head Storm Specs: QUANTAPANEL 506-SL Architectural Low-e Storm Window S sits 0.00 even with QUANTAPANEL 502-PW Architectural Low-e Storm Window S on Low-E emissivity and 0.20 cfm/ft2 looser on AERC air sealing.
ROI vs. Full Replacement: Keeping sound wood frames under 506-SL Architectural Low-e Storm Window S (Two-Track Aluminum) sidesteps $1,000+ unit replacements while capturing ~$350/yr heating and cooling savings.
Climate & Operation Match: Southern targeting with Horizontal Slider hardware (Two-Track track) suits operable ventilation needs under Limited, 20 years OEM coverage.
Which certified ENERGY STAR storm windows sit closest on emissivity and air sealing?
Compare five neighboring EPA ENERGY STAR storm windows ranked closest to QUANTAPANEL 506-SL Architectural Low-e Storm Window S's 0.17 surface emissivity and AERC air sealing.
| Peer Storm Window | Zone Target | Emissivity | Solar Trans. | Air Leakage |
|---|---|---|---|---|
| QUANTAPANEL — 502-PW Architectural Low-e Storm Window S | Southern | 0.17 | 0.46 | 1.10 |
| QUANTAPANEL — 504-DH Architectural Low-e Storm Window S | Southern | 0.17 | 0.46 | 1.30 |
| Innerglass Window Systems — Compression Window | Northern | 0.18 | 0.68 | 0.40 |
| Chosen — Fixed Slip Low-e | Northern | 0.16 | 0.74 | 1.50 |
| QUANTAPANEL — 502-PW Architectural Low-e Storm Window N | Northern | 0.16 | 0.74 | 1.10 |
Who should NOT install storm windows instead of full-frame units?
Confirm whether intact single-pane restoration or full-frame IGU replacement better suits each window opening before specifying QUANTAPANEL 506-SL Architectural Low-e Storm Window S.
Unsound window framing limits QUANTAPANEL storm overlays
Storm panels like 506-SL Architectural Low-e Storm Window S require sound exterior blind stops for perimeter fastening—decayed sills allow rainwater intrusion behind the Aluminum track.
Interior vapor buildup risks with 506-SL Architectural Low-e Storm Window S overlays
Ensure interior wood sashes stay tighter than the exterior 506-SL Architectural Low-e Storm Window S storm track so warm indoor humidity does not condense on cold outer 1 glass.
What historic preservation, payback, and installation questions apply?
Explore frequently asked questions covering QUANTAPANEL 506-SL Architectural Low-e Storm Window S emissivity payback, Two-Track operation, IRC R310 egress rules, and tear-out trade-offs.
Are ENERGY STAR storm tracks like 506-SL Architectural Low-e Storm Window S cost-effective over single-pane glass?
Adding QUANTAPANEL 506-SL Architectural Low-e Storm Window S (0.17 Low-E coating, 1.30 cfm/ft2 air leakage) at ~$188 per opening cuts single-pane conduction and draft losses by roughly 10% annually (~$350/yr), yielding an ~3-year payback.
What frame, track style, and warranty does 506-SL Architectural Low-e Storm Window S carry?
This Southern-rated unit pairs Two-Track Aluminum extrusions with Horizontal Slider operation, 0.46 solar transmittance, and Limited, 20 years OEM support.
Can 506-SL Architectural Low-e Storm Window S be mounted on sleeping room windows under IRC code?
Because 506-SL Architectural Low-e Storm Window S attaches to exterior blind stops rather than shrinking interior jamb liners, bedroom egress width stays intact provided the Horizontal Slider insert opens freely without latching screws.
Who should NOT buy QUANTAPANEL 506-SL Architectural Low-e Storm Window S instead of full replacement?
Do not overlay 506-SL Architectural Low-e Storm Window S (Aluminum) onto rotted perimeter frames, warped sashes that leak rainwater, or existing dual-pane units whose inner glass seals have already failed.
Which official federal and state sources back this page?
Performance metrics, ~$350/yr single-pane savings benchmarks, and unit cost figures for 506-SL Architectural Low-e Storm Window S trace to official federal EPA and DOE datasets.
- ENERGY STAR Certified Storm Windows Dataset (qaxz-ikcb) — U.S. EPA ENERGY STAR, 2026-11 (checked 2026-11-23)
- ENERGY STAR Windows, Doors, Skylights & Storm Windows Homeowner Savings Methodology — U.S. EPA / U.S. DOE ENERGY STAR, v7.0 (checked 2026-11-24)
- National Residential Efficiency Measures Database (REMDB) — Component Unit Cost Formulas — National Renewable Energy Laboratory (U.S. DOE), 2023 Cost Database (checked 2026-11-24)
- International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering) — International Code Council (ICC), 2021/2024 IRC (cite only) (checked 2026-11-23)