QUANTAPANEL — 706-SL Architectural Low-E Storm Window S ENERGY STAR Storm Window Specs
Engineered for Southern single-pane preservation, QUANTAPANEL 706-SL Architectural Low-E Storm Window S delivers 0.19 surface emissivity (under EPA's 0.22 ceiling), 0.44 solar heat transmittance, and 1.10 cfm/ft2 AERC air tightness in an Horizontal Slider Aluminum sash track. Upgrading sound timber frames avoids $1,000+ tear-out bids while recovering ~$188 unit costs via ~$350/yr HVAC bill reductions.
- Low-E Emissivity
- 0.19 (<= 0.22)
- Solar Transmittance
- 0.44
- AERC Air Leakage
- 1.10 cfm/ft2
- Target Zone
- Southern
What optical and air-leakage specifications define QUANTAPANEL 706-SL Architectural Low-E Storm Window S?
Examine QUANTAPANEL 706-SL Architectural Low-E Storm Window S's certified thermal coating metrics, glazing layers, and AERC air-sealing figures alongside climate suitability notes below.
| Storm Window Metric | Certified Value | EPA Benchmark / Engineering Context |
|---|---|---|
| Brand & Partner | QUANTAPANEL | Partner: QUANTA Technologies, Inc. |
| Model Number / Type | 706-SL Architectural Low-E Storm Window S | Exterior Storm Window |
| Emissivity Rating | 0.19 | EPA Low-E threshold <= 0.22 |
| Solar Transmittance | 0.44 | Zone-matched solar gain control |
| AERC 1.2 Air Leakage | 1.10 cfm/ft2 | Reduces single-pane sash drafts |
| Tracks & Glazing | Two-Track · 1 | Aluminum · Limited, 20 Years |
Operating near the upper Low-E margin (0.19 vs. 0.22 EPA limit; 0.02 above the 0.17 median), QUANTAPANEL 706-SL Architectural Low-E Storm Window S trades slightly higher emissivity for lighter glazing tint.
At 0.44 solar transmittance, QUANTAPANEL 706-SL Architectural Low-E Storm Window S delivers all-season solar moderation over single-pane wood frames in Southern climates.
Higher 1.10 cfm/ft2 AERC 1.2 leakage (matching the cohort median) means perimeter weatherstripping on the primary wood sash remains essential alongside 706-SL Architectural Low-E Storm Window S.
Alternative Comparison: Shoppers weighing 706-SL Architectural Low-E Storm Window S (0.19 emissivity, 1.10 cfm/ft2) against QUANTAPANEL 703-FP Architeectural Low-e Storm Window S (0.19 / 0.10) and QUANTAPANEL 704-DH Architectural Low-e Storm Window S (0.19 / 1.10) see 0.00 solar transmittance variance.
ROI vs. Full Replacement: Keeping sound wood frames under 706-SL Architectural Low-E Storm Window S (Two-Track Aluminum) sidesteps $1,000+ unit replacements while capturing ~$350/yr heating and cooling savings.
Installation & Warranty Context: Configured as Exterior Storm Window (Two-Track Aluminum), 706-SL Architectural Low-E Storm Window S carries Limited, 20 Years OEM coverage and requires unobstructed lower sill weep ports.
Which certified ENERGY STAR storm windows sit closest on emissivity and air sealing?
Side-by-side peer specifications benchmark 706-SL Architectural Low-E Storm Window S against five competing certified storm frames on emissivity, solar transmittance, and air leakage.
| Peer Storm Window | Zone Target | Emissivity | Solar Trans. | Air Leakage |
|---|---|---|---|---|
| QUANTAPANEL — 703-FP Architeectural Low-e Storm Window S | Southern | 0.19 | 0.44 | 0.10 |
| QUANTAPANEL — 704-DH Architectural Low-e Storm Window S | Southern | 0.19 | 0.44 | 1.10 |
| Innerglass Window Systems — Compression Window | Northern | 0.18 | 0.68 | 0.40 |
| QUANTAPANEL — 502-PW Architectural T Low-e Storm Window | Northern | 0.20 | 0.77 | 1.10 |
| QUANTAPANEL — 504-DH Architectural T Low-e Storm Window | Northern | 0.20 | 0.77 | 1.30 |
Who should NOT install storm windows instead of full-frame units?
Confirm whether intact single-pane restoration or full-frame IGU replacement better suits each window opening before specifying QUANTAPANEL 706-SL Architectural Low-E Storm Window S.
Unsound window framing limits QUANTAPANEL storm overlays
Avoid concealing deteriorated wood jambs behind QUANTAPANEL 706-SL Architectural Low-E Storm Window S; test putty glazing and lower sill rails prior to taking rough-opening measurements.
Drainage weep slots & coastal exposure for 706-SL Architectural Low-E Storm Window S
Inspect exterior perimeter caulking around 706-SL Architectural Low-E Storm Window S (Southern) and leave bottom weep slots open along the outer sill nose so pressure-equalized moisture escapes freely.
What historic preservation, payback, and installation questions apply?
Explore frequently asked questions covering QUANTAPANEL 706-SL Architectural Low-E Storm Window S emissivity payback, Two-Track operation, IRC R310 egress rules, and tear-out trade-offs.
Are ENERGY STAR storm tracks like 706-SL Architectural Low-E Storm Window S cost-effective over single-pane glass?
Adding QUANTAPANEL 706-SL Architectural Low-E Storm Window S (0.19 Low-E coating, 1.10 cfm/ft2 air leakage) at ~$188 per opening cuts single-pane conduction and draft losses by roughly 10% annually (~$350/yr), yielding an ~3-year payback.
What frame, track style, and warranty does 706-SL Architectural Low-E Storm Window S carry?
This Southern-rated unit pairs Two-Track Aluminum extrusions with Horizontal Slider operation, 0.44 solar transmittance, and Limited, 20 Years OEM support.
Can 706-SL Architectural Low-E Storm Window S be mounted on sleeping room windows under IRC code?
Exterior storm tracks like QUANTAPANEL 706-SL Architectural Low-E Storm Window S mount outboard of existing wood stops, though operable sashes must slide cleanly open to preserve IRC Section R310 5.7 sq ft bedroom escape clearances.
Who should NOT buy QUANTAPANEL 706-SL Architectural Low-E Storm Window S instead of full replacement?
Homeowners with decayed wood sills, broken sash cords, or fogged double-pane IGU seals should choose full replacement over QUANTAPANEL 706-SL Architectural Low-E Storm Window S, as storm panels only preserve structurally sound frames.
Which official federal and state sources back this page?
Verify QUANTAPANEL 706-SL Architectural Low-E Storm Window S certification attributes, AERC air-leakage rules, and residential rebate status against the primary government sources below.
- ENERGY STAR Certified Storm Windows Dataset (qaxz-ikcb) — U.S. EPA ENERGY STAR, 2026-11 (checked 2026-11-23)
- ENERGY STAR Windows, Doors, Skylights & Storm Windows Homeowner Savings Methodology — U.S. EPA / U.S. DOE ENERGY STAR, v7.0 (checked 2026-11-24)
- National Residential Efficiency Measures Database (REMDB) — Component Unit Cost Formulas — National Renewable Energy Laboratory (U.S. DOE), 2023 Cost Database (checked 2026-11-24)
- International Residential Code (IRC) — Sections R310 (Egress), R316.4 (Foam Barrier), R702.7 (Vapor Retarders), R703 (Exterior Covering) — International Code Council (ICC), 2021/2024 IRC (cite only) (checked 2026-11-23)