Skip to main content
Window · Vinyl Frame NFRC AMW · Product Line AMW-K-4 ENERGY STAR Most Efficient Eligible

American Window Alliance, Inc. — Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider · Double Slider

American Window Alliance, Inc. engineered the Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider Double Slider line for Northern, North-Central, South-Central, Southern, certifying 1,472 glass-spacer combinations from 0.21 to 0.32 U-Factor and 0.17 to 0.48 SHGC. Relative to other Vinyl models tracked under NFRC AMW, its minimum U-Factor is 0.02 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.21
SHGC Range
0.17-0.48
Certified Options
1,472
Category Standing
#742 of 1,352

How does American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider compare thermally against Window peers?

American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider achieves a 0.21 thermal floor across Window lines, placing #742 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Windgate/Belmont/Hawthorne/Stormgate 2-Lite SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider (U 0.21).249<=0.153140.16-0.182670.19-0.21This model: U 0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider Cohort StandingMin U-Factor 0.21 stands at rank #742 of 1,352, outperforming 38.6% of peers.Min U-Factor 0.21Rank #742 of 1,352 (38.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider reaches 0.21 on its lowest-conductivity package — #561 of 1,009 in Vinyl, tied with 78 others at 0.21, more insulating than 36.7% of Vinyl lines (+0.02 vs Vinyl peers). Pairing NFRC ID AMW across multi-pane fills shifts U-Factor from 0.32 down toward 0.21.

Climate coverage for American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 8 configurations meet ENERGY STAR Most Efficient criteria while 140 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors AMW to 2023-12-08 certification (FENSTAR issued 2018-02-20). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 126.0 BTU/hr conductive loss (-4.5% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,472 certified glazing combinations for Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider (NFRC AMW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 140 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 492 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 732 packages (0 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,248 packages (8 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.21 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does American Window Alliance, Inc. produce?

Compare other active American Window Alliance, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider appear below.

Where does American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider stand thermally among ENERGY STAR Window lines?

Testing puts American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider at rank #742 of 1,352 Window entries with U 0.21 to 0.32 across 1,472 configurations. Solar heat gain ranges between 0.17 and 0.48 across Northern, North-Central, South-Central, Southern.

Which glazing options in American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider meet Northern climate limits?

Prescriptive Northern compliance covers 140 Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider packages (U floor 0.21, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

How much winter heat loss does Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.21 U-Factor yields 126.0 BTU/hr conductive transfer (-4.5% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 1,248 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider, while total line SHGC reaches 0.48 in colder packages.

What glazing share inside Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider qualifies as Most Efficient?

Not every package qualifies: 8 of 1,472 Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider glazing builds earn Most Efficient recognition (0.5%), while other variants sit on the standard Version 7.0 tier.

What 2026 federal tax credit and Lead RRP rules apply to Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider units match permits?

Match the NFRC thermal sticker for code AMW and line AMW-K-4 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate 2-Lite Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros