Window · Vinyl Frame NFRC AMW · Product Line AMW-K-6 ENERGY STAR Most Efficient Eligible

American Window Alliance, Inc. — Windgate/Belmont/Stormgate/Hawthorne Double Hung · Double Hung

Across 8 American Window Alliance, Inc. certified families, Windgate/Belmont/Stormgate/Hawthorne Double Hung supplies 1,400 Double Hung configurations starting at 0.20 U-Factor and 0.17 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.47 SHGC. Its thermal floor ranks #671 of 1,352 category entries—matches the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.17-0.47
Certified Options
1,400
Category Standing
#671 of 1,352

How does American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung compare thermally against Window peers?

American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Windgate/Belmont/Stormgate/Hawthorne Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Windgate/Belmont/Stormgate/Hawthorne Double Hung (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Windgate/Belmont/Stormgate/Hawthorne Double Hung Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Windgate/Belmont/Stormgate/Hawthorne Double Hung spans 1,400 NFRC test records (AMW), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at +0.01 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.17 to 0.47) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 64 configurations meet ENERGY STAR Most Efficient criteria while 108 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.20 U-Factor yields 120.0 BTU/hr transfer (-12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2024-10-23 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,400 certified glazing combinations for Windgate/Belmont/Stormgate/Hawthorne Double Hung (NFRC AMW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 108 packages (7 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 711 packages (13 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 833 packages (13 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,237 packages (64 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Quaker Window Products — V300 Sidelight Vinyl 0.20 0.13 738
Advanced Window Corp. — 5300 Double Hung Vinyl 0.20 0.15 647
DRUTEX S.A. — IGLO 5 Classic Casement Vinyl 0.20 0.04 2,355
DRUTEX S.A. — IGLO 5 Classic Transom Vinyl 0.20 0.04 2,381
Associated Materials, Inc. — A270/A570/S270/S570 Fixed Vinyl 0.20 0.09 2,471

What other certified series does American Window Alliance, Inc. produce?

Compare other active American Window Alliance, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung appear below.

What thermal performance numbers separate American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung from peers?

Testing puts American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung at rank #671 of 1,352 Window entries with U 0.20 to 0.32 across 1,400 configurations. Solar heat gain ranges between 0.17 and 0.47 across Northern, North-Central, South-Central, Southern.

Which glazing options in American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung meet Northern climate limits?

Yes, 108 packages satisfy Northern ENERGY STAR Version 7.0 rules in Windgate/Belmont/Stormgate/Hawthorne Double Hung. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates Windgate/Belmont/Stormgate/Hawthorne Double Hung from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Windgate/Belmont/Stormgate/Hawthorne Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Can you install American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung in Southern or South-Central zones?

Yes, Windgate/Belmont/Stormgate/Hawthorne Double Hung holds 1,237 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.17 SHGC in cooling climates.

What glazing share inside Windgate/Belmont/Stormgate/Hawthorne Double Hung qualifies as Most Efficient?

Only 64 options out of 1,400 (4.6%) meet tighter Most Efficient U-Factor and SHGC thresholds in American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect Windgate/Belmont/Stormgate/Hawthorne Double Hung?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 American Window Alliance, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify Windgate/Belmont/Stormgate/Hawthorne Double Hung after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line AMW-K-6 and NFRC ID AMW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for American Window Alliance, Inc. Windgate/Belmont/Stormgate/Hawthorne Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros