Skip to main content
Window · Vinyl Frame NFRC ASO · Product Line ASO-A-109 ENERGY STAR Most Efficient Eligible

Associated Materials, Inc. — A270/A570/S270/S570 Fixed · Picture Window

Associated Materials, Inc. A270/A570/S270/S570 Fixed is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.20 across 2,471 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #671 of 1,352 in Window, its thermal floor is matches the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.09 to 0.59.

Min U-Factor
0.20
SHGC Range
0.09-0.59
Certified Options
2,471
Category Standing
#671 of 1,352

How does Associated Materials, Inc. A270/A570/S270/S570 Fixed compare thermally against Window peers?

Associated Materials, Inc. A270/A570/S270/S570 Fixed achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A270/A570/S270/S570 FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing A270/A570/S270/S570 Fixed (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A270/A570/S270/S570 Fixed Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), A270/A570/S270/S570 Fixed reaches 0.20 on its lowest-conductivity package — #513 of 1,009 in Vinyl, tied with 47 others at 0.20, more insulating than 44.5% of Vinyl lines (+0.01 vs Vinyl peers). Pairing NFRC ID ASO across multi-pane fills shifts U-Factor from 0.32 down toward 0.20.

Regional qualification covers Northern, North-Central, South-Central, Southern. 64 configurations meet ENERGY STAR Most Efficient criteria while 473 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-11-19. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.20 conducts 120.0 BTU/hr (-12.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 2,471 certified glazing combinations for A270/A570/S270/S570 Fixed (NFRC ASO) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 473 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 836 packages (4 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 894 packages (3 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 1,743 packages (63 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Associated Materials, Inc. produce?

Compare other active Associated Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Associated Materials, Inc. A270/A570/S270/S570 Fixed appear below.

What U-Factor and SHGC range does Associated Materials, Inc. A270/A570/S270/S570 Fixed achieve?

Associated Materials, Inc. A270/A570/S270/S570 Fixed spans 2,471 certified configurations with U-Factors between 0.20 and 0.32 and SHGC values from 0.09 to 0.59. Ranked #671 of 1,352 Window families, it carries 64 Most Efficient options.

Does Associated Materials, Inc. A270/A570/S270/S570 Fixed qualify for the ENERGY STAR Northern Zone?

Yes, 473 packages satisfy Northern ENERGY STAR Version 7.0 rules in A270/A570/S270/S570 Fixed. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What BTU/hr heat transfer results from A270/A570/S270/S570 Fixed's 0.20 minimum U-Factor?

Using NFRC ASO U-Factor 0.20, a 15 sq ft Fixed Window (FIXD) assembly conducts 120.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-12.0 BTU/hr margin).

When should a buyer skip Associated Materials, Inc. A270/A570/S270/S570 Fixed and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on A270/A570/S270/S570 Fixed options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is A270/A570/S270/S570 Fixed suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 1,743 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Associated Materials, Inc. A270/A570/S270/S570 Fixed, while total line SHGC reaches 0.59 in colder packages.

Does A270/A570/S270/S570 Fixed carry EPA Most Efficient certification across its lineup?

Not every package qualifies: 64 of 2,471 A270/A570/S270/S570 Fixed glazing builds earn Most Efficient recognition (2.6%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 A270/A570/S270/S570 Fixed window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 A270/A570/S270/S570 Fixed installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on A270/A570/S270/S570 Fixed?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code ASO and product line ASO-A-109, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Associated Materials, Inc. A270/A570/S270/S570 Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros