Skip to main content
Window · Vinyl Frame NFRC AMW · Product Line AMW-K-8 ENERGY STAR Most Efficient Eligible

American Window Alliance, Inc. — Windgate/Belmont/Hawthorne/Stormgate Casement · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 528 variants inside American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement, combining Vinyl frame construction with U-Factors spanning 0.19 to 0.31 and SHGC 0.16 to 0.46. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #564 of 1,352 among 1,352 Window families and posts matches the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.19
SHGC Range
0.16-0.46
Certified Options
528
Category Standing
#564 of 1,352

How does American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement compare thermally against Window peers?

American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Windgate/Belmont/Hawthorne/Stormgate CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Windgate/Belmont/Hawthorne/Stormgate Casement (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Windgate/Belmont/Hawthorne/Stormgate Casement Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement standing at #564 of 1,352 certified Window product series, tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%. Comparing Vinyl profiles alone (median 0.19) shows At median before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 71 configurations meet ENERGY STAR Most Efficient criteria while 152 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-02-20 licensing and 2024-01-12 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 528 certified glazing combinations for Windgate/Belmont/Hawthorne/Stormgate Casement (NFRC AMW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 152 packages (6 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 259 packages (14 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 320 packages (13 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 436 packages (70 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does American Window Alliance, Inc. produce?

Compare other active American Window Alliance, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement appear below.

Where does American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement stand thermally among ENERGY STAR Window lines?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement offers 528 Version 7.0 configurations from U 0.19 up to 0.31, posting -0.01 against the Window median of 0.20 with 71 Most Efficient picks.

Which glazing options in American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement meet Northern climate limits?

American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement supplies 152 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.31, so inspect the NFRC order sheet before purchase.

How does a 3x5 ft Windgate/Belmont/Hawthorne/Stormgate Casement window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Windgate/Belmont/Hawthorne/Stormgate Casement the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Windgate/Belmont/Hawthorne/Stormgate Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

How many Windgate/Belmont/Hawthorne/Stormgate Casement glazing packages pass Southern solar-heat rules?

Yes, Windgate/Belmont/Hawthorne/Stormgate Casement holds 436 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

Which package tier in Windgate/Belmont/Hawthorne/Stormgate Casement holds Most Efficient recognition?

Not every package qualifies: 71 of 528 Windgate/Belmont/Hawthorne/Stormgate Casement glazing builds earn Most Efficient recognition (13.4%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 Windgate/Belmont/Hawthorne/Stormgate Casement window swaps?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on Windgate/Belmont/Hawthorne/Stormgate Casement?

Verify NFRC ID AMW and series AMW-K-8 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for American Window Alliance, Inc. Windgate/Belmont/Hawthorne/Stormgate Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)