Skip to main content
Window · Vinyl Frame NFRC LWW · Product Line LWW-K-16 ENERGY STAR Most Efficient Eligible

Lindsay Windows — ClimateSmart / SunView / CrownView Double Hung · Double Hung

With a minimum U-Factor of 0.19—-0.01 compared against the 0.20 Window median—Lindsay Windows ClimateSmart / SunView / CrownView Double Hung spans 495 tested options across Northern, North-Central, South-Central, Southern up to 0.30 U-Factor. Carrying NFRC CPD code LWW, the Vinyl assembly includes 39 ENERGY STAR Most Efficient packages (7.9% of line) and offers SHGC packages between 0.17 and 0.50.

Min U-Factor
0.19
SHGC Range
0.17-0.50
Certified Options
495
Category Standing
#564 of 1,352

How does Lindsay Windows ClimateSmart / SunView / CrownView Double Hung compare thermally against Window peers?

Lindsay Windows ClimateSmart / SunView / CrownView Double Hung achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. ClimateSmart / SunView / CrownView Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing ClimateSmart / SunView / CrownView Double Hung (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

ClimateSmart / SunView / CrownView Double Hung Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Lindsay Windows ClimateSmart / SunView / CrownView Double Hung at rank #564 of 1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.17-0.50 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 39 configurations meet ENERGY STAR Most Efficient criteria while 151 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2022-10-20 and cert timestamp 2024-12-20.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 495 certified glazing combinations for ClimateSmart / SunView / CrownView Double Hung (NFRC LWW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 151 packages (22 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 277 packages (27 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 258 packages (23 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 264 packages (28 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lindsay Windows produce?

Compare other active Lindsay Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lindsay Windows ClimateSmart / SunView / CrownView Double Hung appear below.

How well does ClimateSmart / SunView / CrownView Double Hung by Lindsay Windows insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 495 configurations for Lindsay Windows ClimateSmart / SunView / CrownView Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.19 versus a 0.20 Window median. Only 39 options earn Most Efficient status.

How does Lindsay Windows ClimateSmart / SunView / CrownView Double Hung satisfy Version 7.0 Northern criteria?

Yes. 151 packages in Lindsay Windows ClimateSmart / SunView / CrownView Double Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.30.

How do you calculate winter heat conduction for Lindsay Windows ClimateSmart / SunView / CrownView Double Hung?

Using NFRC LWW U-Factor 0.19, a 15 sq ft Double-Hung (VSDH) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

Who should NOT choose Lindsay Windows ClimateSmart / SunView / CrownView Double Hung for a residential project?

Skip ClimateSmart / SunView / CrownView Double Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on ClimateSmart / SunView / CrownView Double Hung options exceeding U 0.22.

How many ClimateSmart / SunView / CrownView Double Hung glazing packages pass Southern solar-heat rules?

Yes. 264 Southern-certified options inside Lindsay Windows ClimateSmart / SunView / CrownView Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.50 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 495 ClimateSmart / SunView / CrownView Double Hung configurations ENERGY STAR Most Efficient?

Not every package qualifies: 39 of 495 ClimateSmart / SunView / CrownView Double Hung glazing builds earn Most Efficient recognition (7.9%), while other variants sit on the standard Version 7.0 tier.

What 2026 federal tax credit and Lead RRP rules apply to ClimateSmart / SunView / CrownView Double Hung?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Lindsay Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify ClimateSmart / SunView / CrownView Double Hung after sticker removal?

Match the NFRC thermal sticker for code LWW and line LWW-K-16 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lindsay Windows ClimateSmart / SunView / CrownView Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros