Skip to main content
Window · Vinyl Frame NFRC LWW · Product Line LWW-K-21 ENERGY STAR Most Efficient Eligible

Lindsay Windows — ClimateSmart / SunView / CrownView Double Slider · Double Slider

Positioning #564/1,352 in certified Window, Lindsay Windows ClimateSmart / SunView / CrownView Double Slider pairs Vinyl frame construction with 496 glazing options rated between 0.17 and 0.48 SHGC across Northern, North-Central, South-Central, Southern. Across 16 certified Lindsay Windows product families, its thermal resistance spans 0.19 to 0.30 U-Factor and the line includes 32 ENERGY STAR Most Efficient packages (6.5% of line).

Min U-Factor
0.19
SHGC Range
0.17-0.48
Certified Options
496
Category Standing
#564 of 1,352

How does Lindsay Windows ClimateSmart / SunView / CrownView Double Slider compare thermally against Window peers?

Lindsay Windows ClimateSmart / SunView / CrownView Double Slider achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. ClimateSmart / SunView / CrownView Double SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing ClimateSmart / SunView / CrownView Double Slider (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

ClimateSmart / SunView / CrownView Double Slider Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across ClimateSmart / SunView / CrownView Double Slider spans 496 NFRC test records (LWW), ranking #564 of 1,352 Window families (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%). Its 0.19 thermal floor compares at At median against the Vinyl median (0.19).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 32 configurations meet ENERGY STAR Most Efficient criteria while 144 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 114.0 BTU/hr (-13.6% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2022-10-20 and cert timestamp 2024-04-29.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 496 certified glazing combinations for ClimateSmart / SunView / CrownView Double Slider (NFRC LWW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 144 packages (8 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 276 packages (15 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 257 packages (11 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 272 packages (24 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Lindsay Windows produce?

Compare other active Lindsay Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lindsay Windows ClimateSmart / SunView / CrownView Double Slider appear below.

How efficient is Lindsay Windows ClimateSmart / SunView / CrownView Double Slider compared with peer Window models?

Built with Vinyl framing in Dual-Slide Horizontal (HSXX) style, Lindsay Windows ClimateSmart / SunView / CrownView Double Slider offers 496 Version 7.0 configurations from U 0.19 up to 0.30, posting -0.01 against the Window median of 0.20 with 32 Most Efficient picks.

How does Lindsay Windows ClimateSmart / SunView / CrownView Double Slider satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 144 ClimateSmart / SunView / CrownView Double Slider packages (U floor 0.19, SHGC >= 0.17). Because the complete series stretches up to U 0.30, specify the cold-climate glass code explicitly.

How do you calculate winter heat conduction for Lindsay Windows ClimateSmart / SunView / CrownView Double Slider?

Using NFRC LWW U-Factor 0.19, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 114.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-18.0 BTU/hr margin).

Who should NOT choose Lindsay Windows ClimateSmart / SunView / CrownView Double Slider for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on ClimateSmart / SunView / CrownView Double Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is ClimateSmart / SunView / CrownView Double Slider suitable for sunbelt cooling-dominated homes?

Yes, ClimateSmart / SunView / CrownView Double Slider holds 272 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.17 SHGC in cooling climates.

Are all 496 ClimateSmart / SunView / CrownView Double Slider configurations ENERGY STAR Most Efficient?

Within ClimateSmart / SunView / CrownView Double Slider, 6.5% (32 of 496) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Can homeowners claim Form 5695 credits on Lindsay Windows ClimateSmart / SunView / CrownView Double Slider in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 ClimateSmart / SunView / CrownView Double Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC LWW and product line LWW-K-21 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code LWW and product line LWW-K-21, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lindsay Windows ClimateSmart / SunView / CrownView Double Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros